Stem subsidence after total hip revision: 183 cases at 5.9 years follow-up

被引:29
|
作者
Girard, J. [1 ]
Roche, O. [2 ]
Wavreille, G. [3 ]
Canovas, F. [4 ]
Le Beguec, P. [5 ]
机构
[1] N Lille Univ, Sports & Med Unit, F-59000 Lille, France
[2] Nancy Teaching Hosp Ctr, Orthopaed & Traumatol Surg Ctr, F-54000 Nancy, France
[3] Roger Salengro Hosp, Lille Reg Acad Hosp Ctr, Dept Orthopaed, F-59037 Lille, France
[4] Lapeyronie Hosp, Montpellier Teaching Hosp Ctr, Orthopaed & Traumatol Dept, F-34295 Montpellier, France
[5] Galeries Theatre 11, F-35000 Rennes, France
关键词
Revision total hip arthroplasty; Stress shielding; Femorotomy; Press-fit; Stem subsidence; POROUS-COATED STEMS; FEMORAL REVISION; DISTAL FIXATION; ARTHROPLASTY; REPLACEMENT; DISLOCATION; COMPONENTS; FRACTURES; FAILURE; FEMUR;
D O I
10.1016/j.otsr.2010.10.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Secondary subsidence of a revision femoral stem is often a negative predictive sign for successful osseointegration and perfect long-term stability. Materials and methods: We performed a retrospective study in a series of 183 revision total hip replacements between 1996 and 2000 to evaluate the importance and risk factors of secondary subsidence with a cementless press-fit design femoral stem as well as this subsidence's consequences to osseointegration. Results: Secondary subsidence did not occur in 80 cases (53%), was between 0 and 4mm in 41 cases (27%); between 5 and 10mm in 17 cases (12%) and was greater than 10mm in 12 cases (8%). Mean subsidence of all patients was 3mm (0-30). There was a statistically significant negative correlation between subsidence and the quality of osseointegration (P = 0.03). There was no significant relationship between component diameter and stem subsidence (P = 0.9). The presence of preoperative bone deficiencies did not increase the risk of secondary subsidence (P = 0.2). Conclusion: In the case of revision with press-fit stems, the importance of secondary subsidence should not be overestimated, because it usually does not negatively affect satisfactory osseointegration.
引用
收藏
页码:121 / 126
页数:6
相关论文
共 50 条
  • [1] Isolated acetabular revision after total hip arthroplasty: results at 5–9 years of follow-up
    Xiao-Dong Chen
    James P. Waddell
    Jane Morton
    Emil H. Schemitsch
    International Orthopaedics, 2005, 29 : 277 - 280
  • [2] 6 years follow-up of hip revision surgery
    Orban, H.
    Stan, G.
    Gheorghiu, N.
    Dragusanu, M.
    Mares, E.
    Orban, C.
    CHIRURGIA, 2012, 107 (02) : 226 - 230
  • [3] Isolated acetabular revision after total hip arthroplasty: results at 5-9 years of follow-up
    Chen, XD
    Waddell, JP
    Morton, J
    Schemitsch, EH
    INTERNATIONAL ORTHOPAEDICS, 2005, 29 (05) : 277 - 280
  • [4] Multiple revision surgeries after total hip arthroplasty in a patient with osteopetrosis: a case report with 24 years of follow-up
    Wenkang Ling
    Wei He
    Leilei Chen
    BMC Musculoskeletal Disorders, 26 (1)
  • [5] Exchange impaction allografting for femoral revision hip arthroplasty - Results in 87 cases after 3.6 years' follow-up
    Lind, M
    Krarup, N
    Mikkelsen, S
    Horlyck, E
    JOURNAL OF ARTHROPLASTY, 2002, 17 (02): : 158 - 164
  • [6] Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years
    Stefan Lakemeier
    Guenter Aurand
    Nina Timmesfeld
    Thomas J Heyse
    Susanne Fuchs-Winkelmann
    Markus D Schofer
    BMC Musculoskeletal Disorders, 11
  • [7] Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years
    Lakemeier, Stefan
    Aurand, Guenter
    Timmesfeld, Nina
    Heyse, Thomas J.
    Fuchs-Winkelmann, Susanne
    Schofer, Markus D.
    BMC MUSCULOSKELETAL DISORDERS, 2010, 11
  • [8] The use of a long stem cemented femoral component in revision total hip replacement A FOLLOW-UP STUDY OF FIVE TO 16 YEARS
    te Stroet, M. A. J.
    Bronsema, E.
    Rijnen, W. H. C.
    Gardeniers, J. W. M.
    Schreurs, B. W.
    BONE & JOINT JOURNAL, 2014, 96B (09): : 1207 - 1213
  • [9] Cementless Revision for Infected Hip Arthroplasty: an 8.6 Years Follow-up
    Li, Peng
    Hou, Ming
    Zhu, Zhi-qi
    Shi, Zhan-jun
    ORTHOPAEDIC SURGERY, 2015, 7 (01) : 37 - 42
  • [10] Median follow-up results of revision surgery with a hip stem system
    Löhr, JF
    Schütz, U
    Zünd, T
    Drobny, T
    Munzinger, U
    ORTHOPADE, 2001, 30 (05): : 304 - +