The Artificial Urinary Sphincter is Superior to a Secondary Transobturator Male Sling in Cases of a Primary Sling Failure

被引:28
|
作者
Ajay, Divya [1 ]
Zhang, Haijing [2 ]
Gupta, Shubham [3 ]
Selph, John P. [1 ]
Belsante, Michael J. [1 ]
Lentz, Aaron C. [1 ]
Webster, George D. [1 ]
Peterson, Andrew C. [1 ]
机构
[1] Duke Univ, Med Ctr, Div Urol, Dept Surg, Durham, NC 27707 USA
[2] Duke Univ, Med Ctr, Sch Med, Durham, NC 27707 USA
[3] Univ Kentucky, Dept Urol, Lexington, KY USA
来源
JOURNAL OF UROLOGY | 2015年 / 194卷 / 04期
关键词
urethra; prostatectomy; urinary incontinence; stress; suburethral slings; urinary sphincter; artificial; BENIGN PROSTATIC HYPERPLASIA; QUALITY-OF-LIFE; POSTPROSTATECTOMY INCONTINENCE; RADICAL PROSTATECTOMY; POSTRADICAL PROSTATECTOMY; OUTCOMES; IMPLANTATION; CONTINENCE; MANAGEMENT; PLACEMENT;
D O I
10.1016/j.juro.2015.04.106
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We compared continence outcomes in patients with post-prostatectomy stress urinary incontinence treated with a salvage artificial urinary sphincter vs a secondary transobturator sling. Materials and Methods: We retrospectively reviewed the records of patients undergoing salvage procedures after sling failure from 2006 to 2012. Postoperative success was defined as the use of 0 or 1 pad, a negative stress test and pad weight less than 8 gm per day. We performed the Wilcoxon test and used a Cox regression model and Kaplan-Meier survival analysis. Results: A total of 61 men presenting with sling failure were included in study, of whom 32 went directly to an artificial urinary sphincter and 29 received a secondary sling. Of the artificial urinary sphincter cohort 47% underwent prior external beam radiation therapy vs 17% of the secondary sling cohort (p = 0.01). Average preoperative 24 hour pad weight and pad number were higher in the artificial urinary sphincter cohort. Median followup in artificial urinary sphincter and secondary sling cases was 4.5 (IQR 4-12) and 4 months (IQR 1-5), respectively. Overall treatment failure was seen in 55% of patients (16 of 29) with a secondary sling vs 6% (2 of 32) with an artificial urinary sphincter (unadjusted HR 7, 95% CI 2-32 and adjusted HR 6, 95% CI 1-31). Conclusion: In this cohort of patients with post-prostatectomy stress urinary incontinence and a failed primary sling those who underwent a secondary sling procedure were up to 6 times more likely to have persistent incontinence vs those who underwent artificial urinary sphincter placement. These data are useful for counseling patients and planning surgery. We currently recommend placement of an artificial urinary sphincter for patients in whom an initial sling has failed.
引用
收藏
页码:1038 / 1042
页数:5
相关论文
共 50 条
  • [1] THE ARTIFICIAL URINARY SPHINCTER IS SUPERIOR TO A SECONDARY TRANSOBTURATOR MALE SLING IN CASES OF A PRIMARY SLING FAILURE
    Ajay, Divya
    Selph, John
    Belsante, Michael
    Le, Ngoc-Bich
    Lentz, Aaron
    Webster, George
    Peterson, Andrew
    JOURNAL OF UROLOGY, 2015, 193 (04): : E490 - E490
  • [2] Male urinary incontinence: Male sling or artificial sphincter?
    Wille, Sebastian
    AKTUELLE UROLOGIE, 2006, 37 (06) : 411 - 413
  • [3] Readjustable transobturator sling: A novel sling procedure for male urinary incontinence
    Palma, PCR
    Dambros, M
    Thiel, M
    Romano, V
    Griguol, O
    Riccetto, CLZ
    Netto, NR
    UROLOGIA INTERNATIONALIS, 2004, 73 (04) : 354 - 356
  • [4] The male perineal sling - a viable alternative to the artificial urinary sphincter
    Comiter, CV
    NATURE CLINICAL PRACTICE UROLOGY, 2006, 3 (03): : 118 - 119
  • [5] The male perineal sling—a viable alternative to the artificial urinary sphincter
    Craig V Comiter
    Nature Clinical Practice Urology, 2006, 3 : 118 - 119
  • [6] The MASTER trial: artificial urinary sphincter versus male sling
    Abrams, Paul
    Shearer, Kirsty
    TRENDS IN UROLOGY & MENS HEALTH, 2015, 6 (02) : 37 - 38
  • [7] Simultaneous penile prosthesis and male sling/artificial urinary sphincter
    Lee, Dominic
    Romero, Claudio
    Alba, Frances
    Westney, O. Lenaine
    Wang, Run
    ASIAN JOURNAL OF ANDROLOGY, 2013, 15 (01) : 10 - 15
  • [8] OUTCOMES FOR ARTIFICIAL URINARY SPHINCTER PLACEMENT AFTER PRIOR MALE URETHRAL SLING FAILURE
    Ziegelmann, Matthew
    Linder, Brian
    Rivera, Marcelino
    Ogle, Christina
    Elliott, Daniel
    NEUROUROLOGY AND URODYNAMICS, 2015, 34 : S26 - S27
  • [9] OBESITY IS ASSOCIATED WITH MALE TRANSOBTURATOR SLING FAILURE
    Ajay, Divya
    Selph, John
    Belsante, Michael
    Lentz, Aaron
    Ngoc-Bich Le
    Webster, George
    Peterson, Andrew
    JOURNAL OF UROLOGY, 2015, 193 (04): : E1094 - E1095
  • [10] Artificial Urinary Sphincter Outperforms Sling for Moderate Male Stress Urinary Incontinence
    Khouri, Roger K., Jr.
    Ortiz, Nicolas M.
    Baumgarten, Adam S.
    Ward, Ellen E.
    VanDyke, Maia E.
    Hudak, Steven J.
    Morey, Allen F.
    UROLOGY, 2020, 141 : 168 - 172