Method for 3D navigation of airways on a single C-arm using multi-sweep limited angle acquisition and frame-by-frame device reconstruction

被引:2
|
作者
Wagner, Martin G. [1 ]
Periyasamy, Sarvesh [2 ]
Schafer, Sebastian [4 ]
Laeseke, Paul F. [2 ]
Speidel, Michael A. [1 ,3 ]
机构
[1] Univ Wisconsin, Dept Med Phys, 1111 Highland Dr, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Radiol, 1111 Highland Dr, Madison, WI 53705 USA
[3] Univ Wisconsin, Dept Med, 1111 Highland Dr, Madison, WI 53705 USA
[4] Siemens Healthineers, Forchheim, Germany
关键词
Lung Biopsy; 4D Reconstruction; Fluoroscopy; Catheter Tracking; C-arm; TRANSBRONCHIAL BIOPSY; FLEXIBLE BRONCHOSCOPY; PULMONARY-LESIONS; LUNG; COMPETENCE; DIAGNOSIS; SYSTEM;
D O I
10.1117/12.2580957
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Accurate and efficient 3D catheter navigation within the airways is crucial for transbronchial procedures, including biopsy and tumor ablation. While electromagnetic tracking for 3D tip localization exists, it requires specialized equipment, time-consuming registration steps and is prone to CT-to-body divergence. Recently developed techniques allow 3D reconstruction of catheters and curvilinear devices from two simultaneously acquired projection images, but they require a biplane C-arm x-ray system which is not widely available in clinical practice. This study investigates a method of time-resolved 3D tracking of catheters using the more widely available single-plane C-arm system. Imaging was performed using an acquisition protocol where the C-arm continuously rotates back and forth within a limited angular range while acquiring x-ray images. The catheter reconstruction was performed using a sliding window of the most recent x-ray images, which captures information on device shape and position versus time. A model-based approach was used to estimate the catheter shape and position at the time of the last x-ray image acquisition. To evaluate the approach, a pig study was performed where the proposed reconstruction was compared to a gold standard extracted from cone-beam CT (CBCT). The average 3D root mean squared distance between single plane and CBCT reconstruction was 0.8 +/- 0.3mm for a stationary catheter and 2.4 +/- 1.4mm for a catheter moving at similar to 1 cm/s. The tip localization error ranged from 1.0 +/- 0.4mm to 3.8 +/- 2.2mm. The results indicate catheter navigation based on the proposed single plane C-arm imaging technique is feasible with reconstruction errors on the order of the typical ablation catheter diameter (2.0 - 3.2mm).
引用
收藏
页数:9
相关论文
共 37 条
  • [1] Three-dimensional catheter navigation of airways using continuous-sweep limited angle fluoroscopy on a C-arm
    Wagner, Martin G.
    Periyasamy, Sarvesh
    Schafer, Sebastian
    Laeseke, Paul F.
    Speidel, Michael A.
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (05)
  • [2] Reconstruction of 3D ultrasound image from freehand scanned frames using frame-by-frame isotropic correlation functions
    Lee, JH
    Kim, SH
    Kim, NC
    THREE-DIMENSIONAL IMAGE CAPTURE AND APPLICATIONS IV, 2001, 4298 : 195 - 202
  • [3] Reconstruction of 3D ultrasound image from freehand scanned frames using frame-by-frame isotropic correlation functions
    Jun Ho Lee
    Sang Hyun Kim
    Nam Chul Kim
    Proceedings of SPIE - The International Society for Optical Engineering, 2001, 4298 : 195 - 202
  • [4] Modelling the acquisition geometry of a C-arm angiography system for 3D reconstruction
    Cañero, C
    Nofrerías, E
    Mauri, J
    Radeva, P
    TOPICS IN ARTIFICIAL INTELLIGENCE, PROCEEDINGS, 2002, 2504 : 322 - 335
  • [5] A cheap and easy method for 3D C-arm reconstruction using elliptic curves
    Burkhardt, David
    Jain, Ameet
    Fichtinger, Gabor
    MEDICAL IMAGING 2007: VISUALIZATION AND IMAGE-GUIDED PROCEDURES, PTS 1 AND 2, 2007, 6509
  • [6] High Temporal Resolution Time-Resolved C-arm Cone-beam CT Imaging using a Multi-Sweep Data Acquisition Scheme
    Li, Yinsheng
    Garrett, John W.
    Li, Ke
    Strother, Charles
    Chen, Guang-Hong
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [7] Topology observing 3D device reconstruction from continuous-sweep limited angle fluoroscopy
    Wagner, Martin G.
    Kutlu, Ayca Z.
    Davis, Brian
    Raval, Amish N.
    Laeseke, Paul F.
    Speidel, Michael A.
    MEDICAL PHYSICS, 2024, 51 (04) : 2882 - 2892
  • [8] Camera-augmented mobile C-arm (CAMC) application:: 3D reconstruction using a low-cost mobile C-arm
    Navab, N
    Mitschke, M
    Schütz, O
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI'99, PROCEEDINGS, 1999, 1679 : 688 - 697
  • [9] 3D Reconstruction of Wrist Bones from C-Arm Fluoroscopy Using Planar Markers
    Shrestha, Pragyan
    Xie, Chun
    Shishido, Hidehiko
    Yoshii, Yuichi
    Kitahara, Itaru
    DIAGNOSTICS, 2023, 13 (02)
  • [10] 3D Vessel Tree Reconstruction from Rotational C-arm Projections by Multi-view Stereo Reconstruction
    Zhang, Wei
    Chen, Zikuan
    Zhang, Xuefeng
    APCMBE 2008: 7TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2008, 19 : 434 - +