Microfocal X-ray CT imaging and pulmonary arterial distensibility in excised rat lungs

被引:0
|
作者
Karau, KL
Johnson, RH
Molthen, RC
Dhyani, AH
Haworth, ST
Hanger, CC
Roerig, DL
Dawson, CA
机构
[1] Zablocki VAMC, Res Serv 151, Milwaukee, WI 53295 USA
[2] Med Coll Wisconsin, Dept Physiol, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Dept Anesthesiol, Milwaukee, WI 53226 USA
[4] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53201 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2001年 / 281卷 / 03期
关键词
cone beam reconstruction; pulmonary arterial diameter; pulmonary blood flow distribution;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective of this study was to develop an X-ray computed tomographic method for measuring pulmonary arterial dimensions and locations within the intact rat lung. Lungs were removed from rats and their pulmonary arterial trees were filled with perfluorooctyl. bromide to enhance X-ray absorbance. The lungs were rotated within the cone of the X-ray beam projected from a microfocal X-ray source onto an image intensifier, and 360 images were obtained at 1 degrees increments. The three-dimensional image volumes were reconstructed with isotropic resolution using a cone beam reconstruction algorithm. The vessel diameters were obtained by fitting a functional form to the image of the vessel circular cross section. The functional form was chosen to take into account the point spread function of the image acquisition and reconstruction system. The diameter measurements obtained over a range of vascular pressures were used to characterize the distensibility of the rat pulmonary arteries. The distensibility coefficient a [defined by D(P) = D(0)(1 + alphaP), where D(P) is the diameter at intravascular pressure (P)] was similar to2.8% mmHg and independent of vessel diameter in the diameter range (about 100 to 2,000 mm) studied.
引用
收藏
页码:H1447 / H1457
页数:11
相关论文
共 50 条
  • [1] Pulmonary arterial remodeling in the Fawn Hooded rat revealed by microfocal x-ray tomography (CT)
    Karau, K
    Johnson, R
    Molthen, R
    Provoost, A
    Cowley, A
    Jacob, H
    Dawson, C
    FASEB JOURNAL, 2000, 14 (04): : A711 - A711
  • [2] Localized compliance of small airways in excised rat lungs using microfocal X-ray computed tomography
    Sera, T
    Fujioka, H
    Yokota, H
    Makinouchi, A
    Himeno, R
    Schroter, RC
    Tanishita, K
    JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (05) : 1665 - 1673
  • [3] Pulmonary arterial remodeling revealed by microfocal x-ray tomography
    Karau, KL
    Molthen, RC
    Johnson, RH
    Dhyani, AH
    Haworth, ST
    Dawson, CA
    MEDICAL IMAGING 2001: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2001, 4321 : 282 - 287
  • [4] Pulmonary arterial morphometry from microfocal X-ray computed tomography
    Karau, KL
    Molthen, RC
    Dhyani, A
    Haworth, ST
    Hanger, CC
    Roerig, DL
    Johnson, RH
    Dawson, CA
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 281 (06): : H2747 - H2756
  • [5] A microfocal method for phase-contrast X-ray imaging
    Blinov N.N.
    Vasil'ev A.Y.
    Serova N.S.
    Gryaznov A.Y.
    Potrakhov N.N.
    Biomedical Engineering, 2009, 43 (4) : 156 - 160
  • [6] Dental microfocal X-ray processing
    Potrakhov N.N.
    Biomedical Engineering, 2006, 40 (3) : 152 - 154
  • [7] Portable microfocal x-ray diagnostic apparatuses
    Ivanov S.A.
    Potrakhov N.N.
    Biomedical Engineering, 1998, 32 (6) : 310 - 312
  • [8] Lung X-ray and MSCT imaging in patients with essential pulmonary arterial hypertension
    Lazutkina, V.
    Ansheles, A.
    Belichenko, O.
    JOURNAL OF HYPERTENSION, 2008, 26 : S284 - S285
  • [9] Digital X-ray microscopy with a microfocal X-ray generation and an MWPC area detector
    Bateman, J.E.
    Moss, G.R.
    Rockett, P.
    Webb, S.
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 767 - 772
  • [10] DIGITAL X-RAY MICROSCOPY WITH A MICROFOCAL X-RAY GENERATOR AND AN MWPC AREA DETECTOR
    BATEMAN, JE
    MOSS, GR
    ROCKETT, P
    WEBB, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 767 - 772