A Dual-Chambered Hemodialyzer for Convection-Enhanced Hemodialysis

被引:1
|
作者
Lee, Kyungsoo [1 ]
Mun, Cho Hae
Min, Byoung Goo [2 ]
Won, Yong Soon [3 ]
机构
[1] Seoul Natl Univ, Coll Med, Interdisciplinary Program Bioengn, Seoul 110744, South Korea
[2] Seoul Natl Univ, Dept Biomed Engn, Seoul 110744, South Korea
[3] Soonchunhyang Univ, Dept Thorac & Cardiovasc Surg, Puchon, South Korea
关键词
Ultrafiltration; Backfiltration; Transmembrane pressure; Canine renal failure; Clearance; Convection; Dual-chambered hemodialyzer; PATIENTS RECEIVING HEMODIAFILTRATION; HIGH-FLUX HEMODIALYSIS; ONLINE HEMODIAFILTRATION; MORTALITY RISK; DIALYSATE; MODALITY; THERAPY;
D O I
10.1111/j.1525-1594.2011.01402.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Convective clearance during hemodialysis (HD) improves dialysis outcomes in kidney failure patients, and, thus, trials have been undertaken to increase convective mass transfer, which is directly related to internal filtration rates. The authors designed a new hemodialyzer to increase the internal filtration rates, and here describe the hemodialytic efficacy of the devised unit. The developed dual-chambered hemodialyzer (DCH) contains two separate chambers for dialysate flow within a single housing. By placing a flow restrictor on the dialysate stream between these two chambers, dialysate pressures are regulated independently. Dialysate is maintained at a higher pressure than blood pressure in one chamber, and at a lower pressure in the other chamber. The dialysis performance of the DCH was investigated using an acute canine renal failure model. Urea and creatinine reductions and albumin loss were monitored, and forward and backward filtration rates were measured. No procedurally related malfunction was encountered, and animals remained stable without any complications. Urea and creatinine reductions after 4-h dialysis treatments were 75.2 +/- 6.5% and 67.7 +/- 8.9%, respectively. Post-treatment total protein and albumin levels remained at pretreatment values. Total filtration volume was 4.98 +/- 0.5 L over 4 h, whereas the corresponding backfiltration (BF) volume was 4.77 +/- 0.6 L. The developed dual-chamber dialyzer has the benefit of providing independent control of forward filtration and BF rates. HD using this dialyzer provides a straightforward means of increasing the internal filtration and convective dose.
引用
收藏
页码:E78 / E82
页数:5
相关论文
共 50 条
  • [1] Convection-enhanced high-flux hemodialysis
    Lee, Kyungsoo
    Jeong, Jae Hoon
    Mun, Cho Hae
    Lee, Sa Ram
    Yoo, Kyu Jae
    Park, Yong Woo
    Won, Yong Soon
    Min, Byoung Goo
    ARTIFICIAL ORGANS, 2007, 31 (08) : 653 - 658
  • [2] Mathematical analysis for internal filtration of convection-enhanced high-flux hemodialyzer
    Lee, Jung Chan
    Lee, Kyungsoo
    Kim, Hee Chan
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 108 (01) : 68 - 79
  • [3] DUAL-CHAMBERED VIALS SHOULD CARRY WARNINGS ON LABEL
    GARDNER, SN
    DAVIS, HM
    AMERICAN JOURNAL OF HOSPITAL PHARMACY, 1989, 46 (08): : 1548 - 1548
  • [4] Design and Preliminary Testing of a Novel Dual-Chambered Syringe
    May-Newman, Karen
    Matyska, Maria T.
    Lee, Martin N.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2011, 5 (02):
  • [5] BEHAVIOR OF LACTATING RATS IN A DUAL-CHAMBERED MATERNITY CAGE
    GROTA, LJ
    ADER, R
    HORMONES AND BEHAVIOR, 1974, 5 (04) : 275 - 282
  • [6] Dual-chambered membrane bioreactor for coculture of stratified cell populations
    Navarro, Javier
    Swayambunathan, Jay
    Janes, Morgan Elizabeth
    Santoro, Marco
    Mikos, Antonios G.
    Fisher, John P.
    BIOTECHNOLOGY AND BIOENGINEERING, 2019, 116 (12) : 3253 - 3268
  • [7] Cathodic reducing bacteria of dual-chambered microbial fuel cell
    Zhang, Guodong
    Feng, Sansan
    Jiao, Yan
    Lee, Duu-Jong
    Xin, Yanjun
    Sun, Huifang
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (45) : 27607 - 27617
  • [8] NEW CONCEPT IN CIRCULATORY ASSISTANCE - DUAL-CHAMBERED INTRAAORTIC BALLOON
    BREGMAN, D
    GOETZ, RH
    MOUNT SINAI JOURNAL OF MEDICINE, 1972, 39 (02): : 123 - &
  • [9] Convection-enhanced delivery
    Elder, J. Bradley
    Chiocca, E. Antonio
    JOURNAL OF NEUROSURGERY, 2012, 117 (02) : 193 - 195
  • [10] Convection-Enhanced Delivery
    Mehta, A. M.
    Sonabend, A. M.
    Bruce, J. N.
    NEUROTHERAPEUTICS, 2017, 14 (02) : 358 - 371