Development of a branching submaximal treadmill test for predicting VO2max

被引:0
|
作者
Swank, AM [1 ]
Serapiglia, L
Funk, D
Adams, KJ
Durham, M
Berning, JM
机构
[1] Univ Louisville, Exercise Physiol Lab, Louisville, KY 40292 USA
[2] Aultman Hosp, Therapy Serv, Canton, OH USA
[3] Univ Texas, Sport Management Program, Austin, TX 78712 USA
关键词
submaximal testing; treadmill; exercise; predicting VO(2)max;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study determined the reliability and validity of a branching treadmill protocol in predicting (V) over dot O(2)max. Thirty-seven, apparently healthy individuals (19 women and 18 men); volunteered to participate. On 2 separate testing days, each subject underwent maximal exercise testing using the protocol developed. Stepwise regression analysis indicated that the percentage of age-predicted maximum heart rate (APMHR) achieved at stage 3, speed and grade at stage 3, and APMHR accounted for 89% of the variance in (V) over dot O(2)max. The 4 predictor variables were statistically significant (p < 0.01), and the standard error of the estimate was 4.56 ml.kg(-1).min(-1). Results indicate that health and fitness professionals can incorporate this protocol into their practices for the purpose of predicting (V) over dot O(2)max for their clients outside the laboratory environment. Furthermore, our results indicate that using the proposed regression model is reliable and has received preliminary construct validity support.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [1] Validity of a customized submaximal treadmill protocol for determining VO2max
    Cody J. Strom
    Robert W. Pettitt
    Luke M. Krynski
    Nicholas A. Jamnick
    Charles J. Hein
    Cherie D. Pettitt
    European Journal of Applied Physiology, 2018, 118 : 1781 - 1787
  • [2] Validity of a customized submaximal treadmill protocol for determining VO2max
    Strom, Cody J.
    Pettitt, Robert W.
    Krynski, Luke M.
    Jamnick, Nicholas A.
    Hein, Charles J.
    Pettitt, Cherie D.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2018, 118 (09) : 1781 - 1787
  • [3] Body habitus is important in predicting VO2max in overweight children utilizing a submaximal test
    Nemeth, BA
    Carrel, A
    Peterson, S
    Clark, RR
    Sullivan, J
    Allen, D
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S134 - S134
  • [4] Development of a submaximal test to predict elliptical cross-trainer Vo2max
    Dalleck, LC
    Kravitz, L
    Robergs, RA
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2006, 20 (02) : 278 - 283
  • [5] A new submaximal cycle ergometer test for prediction of VO2max
    Ekblom-Bak, E.
    Bjorkman, F.
    Hellenius, M-L.
    Ekblom, B.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2014, 24 (02) : 319 - 326
  • [6] EVALUATION OF THE ACSM SUBMAXIMAL ERGOMETER TEST FOR ESTIMATING VO2MAX
    GREIWE, JS
    KAMINSKY, LA
    WHALEY, MH
    DWYER, GB
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1995, 27 (09): : 1315 - 1320
  • [7] REPRODUCTIBILITY OF VO2MAX - IN TREADMILL ERGOMETRY
    PALENCIANO, L
    GONZALEZ, V
    TERRADOS, N
    MADERA, V
    MONTOLIU, MA
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1989, 414 (01): : S5 - S5
  • [8] Submaximal Treadmill Exercise Test to Predict VO(2)max in Fit Adults
    Vehrs, Pat R.
    George, James D.
    Fellingham, Gilbert W.
    Plowman, Sharon A.
    Dustman-Allen, Kymberli
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2007, 11 (02) : 61 - 72
  • [9] Validity of a submaximal 1-mile track jog test in predicting VO2max in fit teenagers
    Hunt, BR
    George, JD
    Vehrs, PR
    Fisher, AG
    Fellingham, GW
    PEDIATRIC EXERCISE SCIENCE, 2000, 12 (01) : 80 - 90
  • [10] Artificial neural network-based model for predicting VO2max from a submaximal exercise test
    Akay, Mehmet Fatih
    Zayid, Elrasheed Ismail Mohommoud
    Akturk, Erman
    George, James D.
    EXPERT SYSTEMS WITH APPLICATIONS, 2011, 38 (03) : 2007 - 2010