Test beam performance of the electromagnetic calorimeter of the NOMAD experiment

被引:40
|
作者
Autiero, D
BaldoCeolin, M
Bobisut, F
Cattaneo, PW
Camilleri, L
Cavasinni, V
Collazuol, G
Conforto, G
Conta, C
Contalbrigo, M
DelPrete, T
DeSanto, A
Ferrari, R
Fraternali, M
Gibin, D
Gninenko, SN
Graziani, G
Guglielmi, A
Iacopini, E
Kovzelev, AV
LaRotonda, L
Lacaprara, S
Lanza, A
Laveder, M
Lupi, A
Martelli, F
Mezzetto, M
Orestano, D
Pastore, F
Pennacchio, E
Petti, R
Polesello, G
Rimoldi, A
Salvatore, F
Sconza, A
ValdataNappi, M
Veltri, M
Vercesi, V
Volkov, SA
机构
[1] UNIV PADUA,DIPARTIMENTO FIS,PADUA,ITALY
[2] IST NAZL FIS NUCL,PADUA,ITALY
[3] UNIV PISA,DIPARTIMENTO FIS,PISA,ITALY
[4] IST NAZL FIS NUCL,PISA,ITALY
[5] UNIV PAVIA,DIPARTIMENTO FIS NUCL & TEOR,I-27100 PAVIA,ITALY
[6] IST NAZL FIS NUCL,I-27100 PAVIA,ITALY
[7] CERN,CH-1211 GENEVA 23,SWITZERLAND
[8] UNIV FLORENCE,DIPARTIMENTO FIS,FLORENCE,ITALY
[9] IST NAZL FIS NUCL,I-50125 FLORENCE,ITALY
[10] INST NUCL RES,MOSCOW,RUSSIA
[11] UNIV CALABRIA,DIPARTIMENTO FIS,I-87036 COSENZA,ITALY
[12] UNIV URBINO,DIPARTIMENTO FIS,FLORENCE,ITALY
[13] IST NAZL FIS NUCL,GRP COLLEGATO COSENZA,COSENZA,ITALY
关键词
D O I
10.1016/S0168-9002(96)00944-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Test beam results of the NOMAD electromagnetic calorimeter are presented showing linearity, signal uniformity, energy and position resolution measured in an electron beam. Tests were also performed placing the calorimeter in a magnetic field of 0.4 T. Results on the pi rejection obtained using a combined measurement of preshower/electromagnetic calorimeter are found to be in good agreement with the project expectations. Finally the calorimeter response to the muons is discussed.
引用
收藏
页码:352 / 364
页数:13
相关论文
共 50 条
  • [1] The electromagnetic calorimeter of the NOMAD experiment
    Autiero, D
    BaldoCeolin, M
    Barichello, G
    BianchiBonaiti, V
    Bobisut, F
    Cardini, A
    Cattaneo, PW
    Cavasinni, V
    Conta, C
    DelPrete, T
    DeSanto, A
    DiLella, L
    Ferrari, R
    Flaminio, V
    Fraternali, M
    Gibin, D
    Gninenko, SN
    Guglielmi, A
    Iacopini, E
    Kovzelev, AV
    LaRotonda, L
    Lanza, A
    Laveder, M
    Lazzeroni, C
    Livan, M
    Mezzetto, M
    Orestano, D
    Pastore, F
    Pennacchio, E
    Petti, R
    Polesello, G
    Renzoni, G
    Rimoldi, A
    Roda, C
    Sconza, A
    Sobczynski, C
    ValdataNappi, M
    Vascon, M
    Vercesi, V
    Visentin, L
    Volkov, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 373 (03): : 358 - 373
  • [2] CMS electromagnetic calorimeter performance and test beam results
    Bruneliere, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01): : 33 - 35
  • [3] Test beam results on the performance of the CMS electromagnetic calorimeter
    Zabi, Alexandre
    Calorimetry in High Energy Physics, 2006, 867 : 350 - 357
  • [4] Studies of the CMS Electromagnetic Calorimeter performance in the electron test beam
    Arcidiacono, Roberta
    XIII INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 2009, 160
  • [5] THE ELECTROMAGNETIC CALORIMETER IN THE HYPERON BEAM EXPERIMENT AT CERN
    BRUCKNER, W
    CHUDAKOV, E
    EDELHOFF, R
    GERASSIMOV, S
    KALLAKOWSKY, T
    MICHAELS, R
    MULLER, U
    PAUL, S
    POVH, B
    ROHRICH, K
    ROSNER, G
    RUDOLPH, H
    SIEBERT, HW
    VOLKEMER, B
    WALCHER, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 313 (03): : 345 - 356
  • [6] Performance of the electromagnetic calorimeter of the HERMES experiment
    Avakian, H
    Bianchi, N
    Capitani, GP
    De Sanctis, E
    Di Nezza, P
    Fantoni, A
    Giourdjian, V
    Mozzetti, R
    Muccifora, V
    Nupieri, M
    Reolon, AR
    Rossi, P
    van den Brand, JFJ
    Doets, M
    Henkes, T
    Kolstein, M
    Airapetian, A
    Akopov, N
    Amarian, M
    Avakian, R
    Avetissian, A
    Garibian, V
    Taroian, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 417 (01): : 69 - 78
  • [7] Test Beam Performance of the CALICE Scintillator based Electromagnetic Calorimeter Prototype
    Khan, M. Adil
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 1204 - 1210
  • [8] The intercalibration of the CMS electromagnetic calorimeter at the test beam
    Govoni, P.
    Tancini, V.
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2008, 177 : 291 - 292
  • [9] Test beam results on the ATLAS electromagnetic calorimeter
    Di Ciaccio, Lucia
    EUROPEAN PHYSICAL JOURNAL C, 2004, 33 (Suppl 1): : S1005 - S1007
  • [10] First beam test on a BSO electromagnetic calorimeter
    Shimizu, H
    Miyahara, F
    Hariu, H
    Hayakawa, T
    Ishikawa, T
    Itaya, A
    Iwata, T
    Kinoshita, T
    Moriya, M
    Nakabayashi, T
    Sasaki, T
    Tajima, Y
    Takita, S
    Yamamoto, M
    Yamazaki, H
    Yoshida, HY
    Yoshida, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 550 (1-2): : 258 - 266