Understanding the accommodating intraocular lens

被引:23
|
作者
Rana, A [1 ]
Miller, D [1 ]
Magnante, P [1 ]
机构
[1] Cornea Consultants Boston, Boston, MA 02114 USA
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2003年 / 29卷 / 12期
关键词
D O I
10.1016/j.jcrs.2003.07.010
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To review current accommodating intraocular lens (IOL) designs and introduce a new design consisting of a plus lens and a minus lens. Setting. Cornea Consultants of Boston, Boston, Massachusetts, USA. Methods: Computer simulation studies of a model eye calculated the pseudoaccommodation range with different powers of 1 IOL or of 2 IOLs acting as a doublet. Results: The doublet consisting of a convex (plus) lens and a concave (minus) lens gave a greater range of power change than a single convex lens or a doublet consisting of 2 convex lenses. The greater range of power results from the plus lens moving forward. Conclusion: The results show that an IOL design consisting of positive and negative lenses that move closer or farther from each other offers a greater range of pseudoaccommodation than other designs. (C) 2003 ASCRS and ESCRS.
引用
收藏
页码:2284 / 2287
页数:4
相关论文
共 50 条
  • [1] Optical analysis of an accommodating intraocular lens
    Hunter, JJ
    Campbell, MCW
    Geraghty, E
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (02): : 269 - 278
  • [2] Clinical application of accommodating intraocular lens
    You-Ling Liang
    Song-Bai Jia
    International Journal of Ophthalmology, 2018, (06) : 1028 - 1037
  • [3] BIOMIMETIC ACCOMMODATING INTRAOCULAR LENS (IOL)
    DeBoer, Charles
    Do, Hyung Wan
    Lee, Jonathan
    Humayun, Mark
    Tai, Yu-Chong
    2012 IEEE 25TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2012,
  • [4] Clinical application of accommodating intraocular lens
    Liang, You-Ling
    Jia, Song-Bai
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (06) : 1028 - 1037
  • [5] Intraocular Photobonding to Enable Accommodating Intraocular Lens Function
    Alejandre-Alba, Nicolas
    Gutierrez-Contreras, Rocio
    Dorronsoro, Carlos
    Marcos, Susana
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (05):
  • [6] Asymmetric vault of an accommodating intraocular lens
    Jardim, D
    Soloway, B
    Starr, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (02): : 347 - 350
  • [7] A dual optic accommodating foldable intraocular lens
    McLeod, SD
    Portney, V
    Ting, A
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (09) : 1083 - 1085
  • [8] Design and Fabrication of Accommodating Fluidic Intraocular Lens
    Qiao, Wen
    Johnson, Daniel
    Tsai, Frank S.
    Cho, Sung Hwan
    Lo, Yu-Hwa
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 274 - +
  • [9] Accommodating intraocular lens implantation in an epikeratophakia patient
    Labor, Phillips Kirk
    Ignacio, Teresa
    Johnson, Maureen
    Janku-Lestock, Linda
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (02): : 347 - 350
  • [10] Objective measurement of intraocular lens movement and dioptric change with a focus shift accommodating intraocular lens
    Hancox, Joanne
    Spalton, David
    Heatley, Catherine
    Jayararn, Hari
    Marshall, John
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (07): : 1098 - 1103