Comparison of Oligon catheters and chlorhexidine-impregnated sponges with standard multilumen central venous catheters for prevention of associated colonization and infections in intensive care unit patients: A multicenter, randomized, controlled study

被引:49
|
作者
Arvaniti, Kostoula [1 ]
Lathyris, Dimitrios [3 ]
Clouva-Molyvdas, Phyllis
Haidich, Anna-Bettina [4 ]
Mouloudi, Eleni [5 ]
Synnefaki, Eleni [1 ]
Koulourida, Vasiliki [2 ]
Georgopoulos, Dimitrios [6 ]
Gerogianni, Nikoleta [5 ]
Nakos, Georgios [7 ]
Matamis, Dimitrios [1 ]
机构
[1] Papageorgiou Gen Hosp, Intens Care Unit, Thessaloniki, Greece
[2] Papageorgiou Gen Hosp, Dept Microbiol, Thessaloniki, Greece
[3] Gennimatas Gen Hosp, Intens Care Unit, Thessaloniki, Greece
[4] Aristotle Univ Thessaloniki, Sch Med, Dept Hyg & Epidemiol, GR-54006 Thessaloniki, Greece
[5] Ippokratio Gen Hosp, Intens Care Unit, Thessaloniki, Greece
[6] Univ Hosp, Univ Intens Care Unit, Iraklion, Crete, Greece
[7] Univ Hosp, Univ Intens Care Unit, Ioannina, Greece
关键词
catheter-related infection; central venous catheter; chlorhexidine-impregnated sponge; colonization; intensive care; Oligon; BLOOD-STREAM INFECTION; CRITICALLY-ILL PATIENTS; COMPLICATIONS; BACTEREMIA; COST; SITE; MICROORGANISMS; INTERVENTION; EPIDEMIOLOGY; SURVEILLANCE;
D O I
10.1097/CCM.0b013e31822f0d4b
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To evaluate silver-impregnated (Oligon) central venous catheters and chlorhexidine-gluconate-impregnated sponges for reducing catheter-related colonization and infection, nonbacteremic or bacteremic. Design: Multicenter, prospective, randomized, controlled study. Setting: Five general intensive care units in Greece. Patients: Intensive care unit patients requiring a multilumen central venous catheter between June 2006 and May 2008. Interventions: Patients were randomly assigned to receive a standard catheter (standard group), a standard catheter plus chlorhexidine-gluconate-impregnated sponge (chlorhexidine-gluconate-impregnated sponge group), or an Oligon catheter (Oligon group). Catheter colonization was defined as a positive quantitative tip culture (>= 10(3) colony-forming units/mL), catheter-related infection was defined by the previous criterion plus clinical evidence of sepsis, and bacteremia catheter-related infection as catheter-related infection plus a positive peripheral blood culture with the same micro-organism as in the catheter tip. Measurements and Main Results: Data were obtained from 465 patients, 156 in the standard-group, 150 in the chlorhexidine-gluconate-impregnated sponge group, and 159 in the Oligon-group. Colonization occurred in 24 (15.4%) standard catheters, 21 (14%) in the chlorhexidine-gluconate-impregnated sponge group, and 25 (15.7%) in the Oligon catheters (p = .35) (20.9, 19.9, 21.8/1000 catheter-days, respectively). Catheter-related infections were recorded in nine (5.8%) standard catheters, six (4%) in the chlorhexidine-gluconate-impregnated sponge group, and seven (4.4%) in the Oligon catheters (p = .58) (7.8/1,000, 5.7/1,000, 6.1/1,000 catheter-days, respectively). No difference was observed between the chlorhexidine-gluconate-impregnated sponge group and the standard group regarding catheter colonization (hazard ratio 1.21; 95% confidence interval 0.56-2.61; p = .64) and catheter-related infections (hazard ratio 0.65; 95% confidence interval 0.23-1.85; p = .42). The Oligon catheter did not reduce colonization or catheter-related infections when compared with the standard catheter (colonization: hazard ratio 1.0; 95% confidence interval 0.46-2.21; p = .98; catheter-related infection: hazard ratio 0.72; 95% confidence interval 0.27-1.95; p = .52). Seven patients (1.5%, 2.09/1,000 catheter-days) presented bacteremic catheter-related infections. Central venous catheters inserted either in the internal jugular or the femoral vein had greater risk to be colonized than catheters inserted in the subclavian vein (internal jugular vs. subclavian: hazard ratio 3.29; 95% confidence interval 1.26-8.61; p = .01; femoral vs. subclavian: hazard ratio 3.36; 95% confidence interval 1.17-9.65; p = .02). Acinetobacter baumannii was the predominant pathogen (37.1% episodes of colonization, 36.4% catheter-related infections, 57.1% bacteremic catheter-related infections). Conclusion: For short-term (median duration 7 days) central venous catheters in intensive care units with high prevalence of multiresistant Gram-negative bacteria, chlorhexidine-impregnated sponges and Oligon catheters as single preventive measures did not reduce catheter colonization or catheter-related infections. As a result of the limited amount of events, no conclusion could be reached regarding bacteremic catheter-related infections. The femoral site was the most frequently colonized insertion site in all types of catheters. (Crit Care Med 2012; 40:420-429)
引用
收藏
页码:420 / 429
页数:10
相关论文
共 38 条
  • [1] Comparison of Oligon catheters and chlorhexidine-impregnated sponges with standard catheters for prevention of catheter associated colonization and infection: One size does not fit all
    Gowardman, John Robert
    CRITICAL CARE MEDICINE, 2012, 40 (02) : 663 - 665
  • [2] Chlorhexidine-impregnated dressing for prevention of colonization of central venous catheters in infants and children - A randomized controlled study
    Levy, I
    Katz, J
    Solter, E
    Samra, Z
    Vidne, B
    Birk, E
    Ashkenazi, S
    Dagan, O
    PEDIATRIC INFECTIOUS DISEASE JOURNAL, 2005, 24 (08) : 676 - 679
  • [3] Comparison of oligon central venous catheters with standard multilumen central venous catheters in cardiac surgery ICU patients
    I Mpisiadis
    E Douka
    I Kriaras
    D Markantonaki
    S Geroulanos
    Critical Care, 12 (Suppl 2):
  • [4] Double-lumen central venous catheters impregnated with chlorhexidine and silver sulfadiazine as a prevention of catheter colonization in the intensive care unit setting: a prospective randomized study
    L Camargo
    G Büchele
    A Marra
    R Cal
    J Sousa
    F Machado
    A Sogayar
    V Michels
    E Silva
    M Martino
    E Knobel
    L Poli
    Critical Care, 8 (Suppl 1):
  • [5] Evaluation of the infections due to central venous catheters in intensive care unit patients
    L Ýyilikçi
    C Eyigör
    A Atay
    Ü Evliya
    N Koroðlu
    M Çelik
    A Günerli
    Critical Care, 3 (Suppl 1):
  • [6] Chlorhexidine-Impregnated Dressings and Prevention of Catheter-Associated Bloodstream Infections in a Pediatric Intensive Care Unit
    Duzkaya, Duygu Sonmez
    Sahiner, Nejla Canbulat
    Uysal, Gulzade
    Yakut, Tulay
    Citak, Agop
    CRITICAL CARE NURSE, 2016, 36 (06) : 12 - 12
  • [7] Comparison of triple-lumen central venous catheters impregnated with silver nanoparticles (AgTive®) vs conventional catheters in intensive care unit patients
    Antonelli, M.
    De Pascale, G.
    Ranieri, V. M.
    Pelaia, P.
    Tufano, R.
    Piazza, O.
    Zangrillo, A.
    Ferrario, A.
    De Gaetano, A.
    Guaglianone, E.
    Donelli, G.
    JOURNAL OF HOSPITAL INFECTION, 2012, 82 (02) : 101 - 107
  • [8] Central venous catheter colonization in critically ill patients:: A prospective, randomized, controlled study comparing standard with two antiseptic-impregnated catheters
    Dünser, MW
    Mayr, AJ
    Hinterberger, G
    Flörl, CL
    Ulmer, H
    Schmid, S
    Friesenecker, B
    Lorenz, I
    Hasibeder, WR
    ANESTHESIA AND ANALGESIA, 2005, 101 (06): : 1778 - 1784
  • [9] Evaluation of chlorhexidine and silver-sulfadiazine impregnated central venous catheters for the prevention of bloodstream infection in leukaemic patients: a randomized controlled trial
    Logghe, C
    VanOssel, C
    DHoore, W
    Ezzedine, H
    Wauters, G
    Haxhe, JJ
    JOURNAL OF HOSPITAL INFECTION, 1997, 37 (02) : 145 - 156
  • [10] Evaluation of antiseptic-impregnated central venous catheters for prevention of catheter-related infection in intensive care unit patients
    Sheng, WH
    Ko, WJ
    Wang, JT
    Chang, SC
    Hsueh, PR
    Luh, KT
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2000, 38 (01) : 1 - 5