Optimization of stand-alone and grid-connected hybrid solar/wind/fuel cell power generation for green islands: Application to Koh Samui, southern Thailand

被引:34
|
作者
Chaichan, Weerasak [1 ]
Waewsak, Jompob [2 ]
Nikhom, Ruamporn [1 ]
Kongruang, Chuleerat [3 ]
Chiwamongkhonkarn, Somphol [1 ]
Gagnon, Yves [4 ]
机构
[1] Thaksin Univ, Fac Engn, Energy Engn Program, Phanhalung Campus, Phatthalung 93210, Thailand
[2] Thaksin Univ, Res Ctr Energy & Environm RCEE, Phatthalung Campus, Phatthalung 93210, Thailand
[3] Walailak Univ, Sch Accountancy & Finance, Nakhon Si Thammarat 80160, Thailand
[4] Univ Moncton, Edmundston, NB, Canada
关键词
Hybrid renewable energy; Energy storage; Fuel cell; Optimization; Levelized cost of energy; Solar PV and wind energy; RENEWABLE ENERGY SYSTEM; ELECTRIFICATION; CARBON; PLANT;
D O I
10.1016/j.egyr.2022.07.024
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents the optimization of stand-alone and grid-connected hybrid power generation systems for green islands, with application to Koh Samui in southern Thailand. A techno-economic optimization analysis is applied using the Hybrid Optimization Model for Electric Renewable (HOMER) Pro simulation tool. Four scenarios are identified to select the most suitable solution for a hybrid renewable energy system (HRES) integrating solar photovoltaic (PV), wind turbine generator (WTG), fuel cell (FC), and battery energy storage (Li-Ion), with backup diesel generation or grid connection with the mainland as options. The NASA-SSE and MERRA databases are used as inputs to analyze the solar and wind energy potentials, respectively. The results show that the levelized cost of energy (LCOE) of the HRES with a grid connection to the mainland (Scenario 3) has the lowest LCOE (0.132 US$/kWh), but at large greenhouse gas (GHG) emission costs (20.5 ktonnes/year) due to the high carbon intensity of Thailand's power portfolio. A stand-alone, 100% renewable energy system (Scenario 4) includes a PV capacity of 182 MW, a wind power capacity of 8 MW, a fuel cell system of 10 MW, a 17.9 MW power converter, and 211 MWh of battery storage. The net present cost (NPC) of this system is 542 MUS$ and the LCOE is 0.309 US$/kWh, with 89% of the energy generated by the solar PV system. Therefore, a 100% renewable energy-based microgrid system is possible on Koh Samui as it can provide a more suitable and reliable solution when considering a HRES system for the total load demand (104 MW of peak load) of the island. Finally, the economic analysis also reveals that the investment in a HRES system is feasible as the payback period is 9 years under an internal rate of return (IRR) of 10% and an appropriate Feed-in-Tariff (FiT) of 0.385 US$/kWh. (C) 2022 The Author(s). Published by Elsevier Ltd.
引用
收藏
页码:480 / 493
页数:14
相关论文
共 42 条
  • [1] Microgrid Hybrid Solar/Wind/Diesel and Battery Energy Storage Power Generation System: Application to Koh Samui, Southern Thailand
    Khamharnphol, Rawit
    Kamdar, Ismail
    Waewsak, Jompob
    Chaichan, Weerasak
    Khunpetch, Sakrapee
    Chiwamongkhonkarn, Somphol
    Kongruang, Chuleerat
    Gagnon, Yves
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY DEVELOPMENT-IJRED, 2023, 12 (02): : 216 - 226
  • [2] Unit sizing of stand-alone hybrid Wind/PV/Fuel Cell Power Generation Systems
    Nelson, DB
    Nehrir, MH
    Wang, C
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 2116 - 2122
  • [3] Power fluctuations suppression of stand-alone hybrid generation combining solar photovoltaic/wind turbine and fuel cell systems
    Ahmed, Nabil A.
    Miyatake, Masafumi
    Al-Othman, A. K.
    ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (10) : 2711 - 2719
  • [4] Voltage and power control used to stabilise the distributed generation system for stand-alone or grid-connected operation
    Querubini Goncalves, Amilcar Flamarion
    Aguiar, Cassius R.
    Bastos, Renan F.
    Pozzebon, Giovani G.
    Machado, Ricardo Q.
    IET POWER ELECTRONICS, 2016, 9 (03) : 491 - 501
  • [5] Size optimization of stand-alone PV/wind/diesel hybrid power generation systems
    Shi, Bin
    Wu, Wei
    Yan, Liexiang
    JOURNAL OF THE TAIWAN INSTITUTE OF CHEMICAL ENGINEERS, 2017, 73 : 93 - 101
  • [6] Unit sizing and cost analysis of stand-alone hybrid wind/PV/fuel cell power generation systems
    Nelson, D. B.
    Nehrir, M. H.
    Wang, C.
    RENEWABLE ENERGY, 2006, 31 (10) : 1641 - 1656
  • [7] Optimization of a stand-alone Solar PV-Wind-DG Hybrid System for Distributed Power Generation at Sagar Island
    Roy, P. C.
    Majumder, A.
    Chakraborty, N.
    INTERNATIONAL CONFERENCE ON MODELING, OPTIMIZATION, AND COMPUTING, 2010, 1298 : 260 - +
  • [8] Comparative techno-economic analysis of various stand-alone and grid connected (solar/wind/fuel cell) renewable energy systems
    Manoo, Mansoor Urf
    Shaikh, Faheemullah
    Kumar, Laveet
    Arici, Muslum
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 52 : 397 - 414
  • [9] Techno-economic feasibility of photovoltaic, wind and hybrid electrification systems for stand-alone and grid-connected shipyard electrification in Italy
    Vakili, Seyedvahid
    Schonborn, Alessandro
    Olcer, Aykut, I
    JOURNAL OF CLEANER PRODUCTION, 2022, 366
  • [10] FEASIBILITY ANALYSIS AND OPTIMIZATION OF STAND-ALONE FUEL CELL/WIND TURBINE/PV HYBRID ENERGY SYSTEM
    Nikolova-Poceva, Sofija
    INTERNATIONAL JOURNAL ON INFORMATION TECHNOLOGIES AND SECURITY, 2021, 13 : 39 - 50