Early Outcomes of INTRACOR Femtosecond Laser Treatment for Presbyopia

被引:54
|
作者
Holzer, Mike P. [1 ]
Mannsfeld, Annett [1 ]
Ehmer, Angela [1 ]
Auffarth, Gerd U. [1 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, IVCRC, D-69120 Heidelberg, Germany
关键词
IN-VIVO; REFRACTIVE SURGERY; PULSES; PICOSECOND; PRESBYLASIK; TISSUE;
D O I
10.3928/1081597X-20090917-06
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To-investigate early functional outcomes of the INTRACOR femtosecond laser-based intrastromal procedure to treat presbyopia. METHODS: Twenty-five eyes of 25 presbyopic patients were enrolled in this prospective, ethics committee-approved study. Following detailed preoperative examination, the INTRACOR procedure was performed using the TECHNOLAS femtosecond laser (Technolas Perfect Vision GmbH) in the non-dominant eye. Postoperatively, follow-up examinations were performed at 1 day, 1 week, and 1 and 3 months, including near and distance visual acuity, slit-lamp microscopy, and corneal topography, RESULTS: All 25 surgeries were uneventful. The mean postoperative uncorrected near visual acuity increased from 0.7 +/- 0.16 logMAR to 0.26 +/- 10.21 logMAR and the mean uncorrected distance visual acuity changed slightly from 0.11 +/- 0.11 logMAR to 0.05 +/- 0.1 logMAR at 3 months postoperative. Regarding best distance correction, mean sphere changed from +0.75 +/- 0.23 diopters (D) preoperatively to +0.15 +/- 0.31 D postoperatively and mean cylinder from -0.33 +/- 0.17 D to -0.42 +/- 0.23 D. Postoperative healing was uneventful, and in all eyes, the cornea was clear within a few hours after surgery without any remaining cavitation gas bubbles. CONCLUSIONS: The INTRACOR procedure for presbyopia showed good visual acuity outcomes in the early postoperative period. The short treatment time in combination with maintained corneal integrity suggests this new technique has good potential for the treatment of presbyopia. [J Refract Surg. 2009;25:855-861.] doi:10.3928/1081597X-20090917-06
引用
收藏
页码:855 / 861
页数:7
相关论文
共 50 条
  • [1] Corneal imaging of intrastromal femtosecond laser treatment for presbyopia (Intracor®)
    Trinh, L.
    Francoz, M.
    Chong-Sit, D.
    Labbe, A.
    Dupont-Monod, S.
    Baudouin, C.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2013, 36 (08): : 669 - 676
  • [2] Refractive Outcomes of Cataract Surgery in Patients With Intrastromal Femtosecond Laser Treatment of Presbyopia (INTRACOR)
    Naujokaitis, Tadas
    Hallak, Mustafa K.
    Bloeck, Louise
    Khoramnia, Ramin
    Auffarth, Gerd U.
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (10) : 676 - +
  • [3] Femtosecond Laser Correction of Presbyopia (INTRACOR) in Emmetropes Using a Modified Pattern
    Thomas, Bettina C.
    Fitting, Anna
    Auffarth, Gerd U.
    Holzer, Mike P.
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (12) : 872 - 878
  • [4] Effect of intrastromal correction of presbyopia with femtosecond laser (INTRACOR) on mesopic contrast sensitivity
    Fitting, A.
    Menassa, N.
    Auffarth, G. U.
    Holzer, M. P.
    OPHTHALMOLOGE, 2012, 109 (10): : 1001 - 1007
  • [5] Keratectasia After Presbyopia Treatment With INTRACOR
    Lun, Katherine
    Ray, Manotosh
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S333 - S336
  • [6] Presbyopia treatment using a femtosecond laser
    Blum, M.
    Kunert, K.
    Nolte, S.
    Riehemann, S.
    Palme, M.
    Peschel, T.
    Dick, M.
    Dick, H. B.
    OPHTHALMOLOGE, 2006, 103 (12): : 1014 - 1019
  • [7] Investigations for the treatment of presbyopia with femtosecond laser pulses
    Gerten, GJ
    Ripken, T
    Ziltz, C
    Kermani, O
    Oberheide, U
    Lubatschowski, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [8] Auswirkungen intrastromaler Presbyopiebehandlung mittels Femtosekundenlaser (INTRACOR) auf die mesopische KontrastsensitivitätEffect of intrastromal correction of presbyopia with femtosecond laser (INTRACOR) on mesopic contrast sensitivity
    A. Fitting
    N. Menassa
    G.U. Auffarth
    M.P. Holzer
    Der Ophthalmologe, 2012, 109 (10): : 1001 - 1007
  • [9] Agreement of subjective and objective refraction measurements following INTRACOR femtosecond laser treatment
    Fitting, A.
    Ehmer, A.
    Rabsilber, T. M.
    Auffarth, G. U.
    Holzer, M. P.
    OPHTHALMOLOGE, 2011, 108 (09): : 852 - 858
  • [10] Cataract surgery after previous femtosecond laser intrastromal presbyopia treatment
    Fitting, Anna
    Rabsilber, Tanja M.
    Auffarth, Gerd U.
    Holzer, Mike P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07): : 1293 - 1297