Coronary artery wall imaging in mice using osmium tetroxide and micro-computed tomography (micro-CT)

被引:35
|
作者
Pai, Vinay M. [1 ]
Kozlowski, Megan [1 ]
Donahue, Danielle [6 ]
Miller, Elishiah [1 ,8 ]
Xiao, Xianghui [7 ]
Chen, Marcus Y. [2 ]
Yu, Zu-Xi [3 ]
Connelly, Patricia [4 ]
Jeffries, Kenneth [5 ]
Wen, Han [1 ]
机构
[1] NHLBI, Imaging Phys Grp, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA
[2] NHLBI, Adv Cardiovasc Imaging Grp, NIH, Bethesda, MD 20892 USA
[3] NHLBI, Pathol Core Facil, NIH, Bethesda, MD 20892 USA
[4] NHLBI, Electron Microscopy Core Facil, NIH, Bethesda, MD 20892 USA
[5] NHLBI, LAMS, NIH, Bethesda, MD 20892 USA
[6] NINDS, MIF, NIH, Bethesda, MD 20892 USA
[7] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
[8] Univ Texas El Paso, Dept Comp Sci, El Paso, TX 79968 USA
基金
美国国家卫生研究院;
关键词
apolipoprotein E; atherosclerosis; coronary artery wall; micro-computed tomography; osmium; MOUSE EMBRYOS; HYPERCHOLESTEROLEMIA; LESIONS;
D O I
10.1111/j.1469-7580.2012.01483.x
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The high spatial resolution of micro-computed tomography (micro-CT) is ideal for 3D imaging of coronary arteries in intact mouse heart specimens. Previously, micro-CT of mouse heart specimens utilized intravascular contrast agents that hardened within the vessel lumen and allowed a vascular cast to be made. However, for mouse coronary artery disease models, it is highly desirable to image coronary artery walls and highlight plaques. For this purpose, we describe an ex vivo contrast-enhanced micro-CT imaging technique based on tissue staining with osmium tetroxide (OsO4) solution. As a tissue-staining contrast agent, OsO4 is retained in the vessel wall and surrounding tissue during the fixation process and cleared from the vessel lumens. Its high X-ray attenuation makes the artery wall visible in CT. Additionally, since OsO4 preferentially binds to lipids, it highlights lipid deposition in the artery wall. We performed micro-CT of heart specimens of 5- to 25-week-old C57BL/6 wild-type mice and 5- to 13-week-old apolipoprotein E knockout (apoE-/-) mice at 10 mu m resolution. The results show that walls of coronary arteries as small as 45 mu m in diameter are visible using a table-top micro-CT scanner. Similar image clarity was achieved with 1/2000th the scan time using a synchrotron CT scanner. In 13-week-old apoE mice, lipid-rich plaques are visible in the aorta. Our study shows that the combination of OsO4 and micro-CT permits the visualization of the coronary artery wall in intact mouse hearts.
引用
收藏
页码:514 / 524
页数:11
相关论文
共 50 条
  • [1] Coronary wall imaging in mice using osmium tetroxide and micro-computed tomography
    Kozlowski, M.
    Donohue, D.
    Chen, M.
    Daniels, M.
    Connelly, P.
    Jeffries, K.
    Clevenger, R.
    Wen, H.
    Pai, V. M.
    MOLECULAR IMAGING III, 2011, 8089
  • [2] Assessment of bone quality using micro-computed tomography (micro-CT) and synchrotron micro-CT
    Ito, M
    JOURNAL OF BONE AND MINERAL METABOLISM, 2005, 23 (Suppl 1) : 115 - 121
  • [3] Assessment of bone quality using micro-computed tomography (micro-CT) and synchrotron micro-CT
    Masako Ito
    Journal of Bone and Mineral Metabolism, 2005, 23 : 115 - 121
  • [4] Analysis of Orthodontically Induced Root Resorption Using Micro-Computed Tomography (Micro-CT)
    Wierzbicki, Tom
    El-Bialy, Tarek
    Aidaghreer, Saleh
    Li, Guang
    Doschak, Michael
    ANGLE ORTHODONTIST, 2009, 79 (01) : 91 - 96
  • [5] Micro-computed tomography (Micro-CT): a novel approach for intraoperative breast cancer specimen imaging
    Rong Tang
    Julliette M. Buckley
    Leopoldo Fernandez
    Suzanne Coopey
    Owen Aftreth
    James Michaelson
    Mansi Saksena
    Lan Lei
    Michelle Specht
    Michele Gadd
    Yukako Yagi
    Elizabeth Rafferty
    Elena Brachtel
    Barbara L. Smith
    Breast Cancer Research and Treatment, 2013, 139 : 311 - 316
  • [6] Micro-computed tomography (Micro-CT): a novel approach for intraoperative breast cancer specimen imaging
    Tang, Rong
    Buckley, Julliette M.
    Fernandez, Leopoldo
    Coopey, Suzanne
    Aftreth, Owen
    Michaelson, James
    Saksena, Mansi
    Lei, Lan
    Specht, Michelle
    Gadd, Michele
    Yagi, Yukako
    Rafferty, Elizabeth
    Brachtel, Elena
    Smith, Barbara L.
    BREAST CANCER RESEARCH AND TREATMENT, 2013, 139 (02) : 311 - 316
  • [7] Assessment of Global Ocular Structure Following Spaceflight Using a Micro-Computed Tomography (Micro-CT) Imaging Method
    Roque-Torres, Gina D.
    Nishiyama, Nina C.
    Stanbouly, Seta
    Mao, Xiao Wen
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2020, (164):
  • [8] Coronary micro-computed tomography angiography in mice
    Sawall, Stefan
    Beckendorf, Jan
    Amato, Carlo
    Maier, Joscha
    Backs, Johannes
    Vande Velde, Greetje
    Kachelriess, Marc
    Kuntz, Jan
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [9] Coronary micro-computed tomography angiography in mice
    Stefan Sawall
    Jan Beckendorf
    Carlo Amato
    Joscha Maier
    Johannes Backs
    Greetje Vande Velde
    Marc Kachelrieß
    Jan Kuntz
    Scientific Reports, 10
  • [10] Application of micro-computed tomography (micro-CT) to study unevenness of the structure of yarns
    Toda, Marta
    Grabowska, Katarzyna
    Ciesielska-Wrobel, Izabela
    TEXTILE RESEARCH JOURNAL, 2017, 87 (03) : 351 - 368