Enzymatic determination of L(+) lactic and L(-) malic acids in wines by flow-injection spectrophotometry

被引:21
|
作者
Lima, JLFC
Lopes, TIMS
Rangel, AOSS
机构
[1] Univ Porto, Fac Farm, Dept Quim Fis, CEQUP, P-4050 Porto, Portugal
[2] Univ Catolica Portuguesa, Escola Super Biotecnol, P-4200 Porto, Portugal
关键词
sequential flow injection; L(+) lactic acid; L(-) malic acid; spectrophotometric enzymatic determination; wines;
D O I
10.1016/S0003-2670(98)00106-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection system for the enzymatic determination of L(+) lactic acid and L(-) malic acid in wines with spectrophotometric detection is described. The samples are dialysed in-line, and the enzymes in solution (malate dehydrogenase and lactate dehydrogenase) an injected as a train of plugs in the acceptor stream of the dialysis unit, yielding two peaks corresponding to the NADH formed for each determination. This methodology enables the determination of both acids with a single detector with a sampling rate of 20 h(-1) (0.4-3 g l(-1)). The results are comparable to those obtained by the reference procedure, the repeatability is better than 5% (rsd), with low enzyme consumption (1.3 mu l of suspension per sample). (C) 1998 Elsevier Science B.V.
引用
收藏
页码:187 / 191
页数:5
相关论文
共 50 条
  • [1] ENZYMATIC DETERMINATION OF L(-)MALIC AND L(+)LACTIC ACIDS IN WINE BY FLOW-INJECTION ANALYSIS
    LIMA, JLFC
    RANGEL, AOSS
    AMERICAN JOURNAL OF ENOLOGY AND VITICULTURE, 1992, 43 (01): : 58 - 62
  • [2] SIMULTANEOUS ENZYMATIC DETERMINATION OF L(-) MALIC-ACID AND L(+) LACTIC-ACID IN WINE BY FLOW-INJECTION ANALYSIS
    PUCHADES, R
    HERRERO, MA
    MAQUIEIRA, A
    ATIENZA, J
    FOOD CHEMISTRY, 1991, 42 (02) : 167 - 182
  • [3] ENZYMATIC DETERMINATION OF L-LYSINE BY FLOW-INJECTION TECHNIQUES
    POHLMANN, A
    STAMM, WW
    KUSAKABE, H
    KULA, MR
    ANALYTICA CHIMICA ACTA, 1990, 235 (02) : 329 - 335
  • [4] ENZYMATIC DETERMINATION OF FREE L-(-)-MALIC ACID IN MUST AND WINE BY STOPPED-FLOW FLOW-INJECTION ANALYSIS
    DEMARIA, CG
    MUNOZ, TM
    MATEOS, AA
    ANALYTICA CHIMICA ACTA, 1991, 247 (01) : 61 - 65
  • [5] Compact analytical flow system for the simultaneous determination of l-lactic and l-malic in red wines
    Pablo Giménez-Gómez
    Manuel Gutiérrez-Capitán
    Fina Capdevila
    Anna Puig-Pujol
    Cecilia Jiménez-Jorquera
    César Fernández-Sánchez
    Scientific Reports, 10
  • [6] Compact analytical flow system for the simultaneous determination of l-lactic and l-malic in red wines
    Gimenez-Gomez, Pablo
    Gutierrez-Capitan, Manuel
    Capdevila, Fina
    Puig-Pujol, Anna
    Jimenez-Jorquera, Cecilia
    Fernandez-Sanchez, Cesar
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [7] DETERMINATION OF PARAQUAT BY FLOW-INJECTION SPECTROPHOTOMETRY
    JAIN, A
    VERMA, KK
    TOWNSHEND, A
    ANALYTICA CHIMICA ACTA, 1993, 284 (02) : 275 - 279
  • [8] DETERMINATION OF PARAQUAT BY FLOW-INJECTION SPECTROPHOTOMETRY
    GUIJARRO, EC
    YANEZSEDENO, P
    DIEZ, LMP
    ANALYTICA CHIMICA ACTA, 1987, 199 : 203 - 208
  • [9] INDIVIDUAL AND SIMULTANEOUS ENZYMATIC DETERMINATION OF ETHANOL AND ACETALDEHYDE IN WINES BY FLOW-INJECTION ANALYSIS
    LAZARO, F
    DECASTRO, MDL
    VALCARCEL, M
    ANALYTICA CHIMICA ACTA, 1986, 185 : 57 - 64
  • [10] Electrochemical biosensors for assays of L-malic and D-lactic acids in wines
    Gilis, M
    Durliat, H
    Comtat, M
    AMERICAN JOURNAL OF ENOLOGY AND VITICULTURE, 1996, 47 (01): : 11 - 16