Intracranial dural arteriovenous fistulas: Evaluation with combined 3D time-of-flight MR angiography and MR digital subtraction angiography

被引:69
|
作者
Noguchi, K
Melhem, ER
Kanazawa, T
Kubo, M
Kuwayama, N
Seto, H
机构
[1] Toyama Med & Pharmaceut Univ, Dept Radiol, Toyama 9300194, Japan
[2] Univ Penn, Med Ctr, Dept Radiol, Neuroradiol Sect, Philadelphia, PA 19104 USA
[3] Toyama Med & Pharmaceut Univ, Dept Neurosurg, Toyama 9300194, Japan
关键词
D O I
10.2214/ajr.182.1.1820183
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare the diagnostic utility of 3D time-of-flight (TOF) MR angiography and MR digital subtraction angiography in patients with angiographically proven moderate- to high-flow intracranial dural arteriovenous fistula. MATERIALS AND METHODS. Two neuroradiologists, unaware of patients' histories and angiographic findings, retrospectively reviewed 17 MR angiograms with 3D TOF MR angiography and MR digital subtraction angiography in 15 patients with dural arteriovenous fistula and also reviewed 35 MR angiograms in control patients without findings of dural arteriovenous fistula on angiography. Disagreements were resolved by consensus. RESULTS. In patients with dural arteriovenous fistula, source images of 3D TOF MR angiography showed two abnormal findings: multiple high-intensity curvilinear or nodular structures adjacent to the sinus wall and high-intensity areas in the venous sinus. Findings of multiple high-intensity structures adjacent to the sinus wall were observed in all cases of dural arteriovenous fistula. Findings of high-intensity areas in the venous sinus were observed in 13 of 17 cases of dural arteriovenous fistula. Findings of multiple high-intensity structures adjacent to the sinus wall were not observed in any control subjects. Findings of high-intensity areas within the venous sinus were observed in five of 35 control subjects. Findings of MR digital subtraction angiography showed early filling of the venous sinus, suggestive of dural arteriovenous fistula, in 13 of 15 patients with dural arteriovenous fistula. Sensitivity and specificity of multiple high-intensity structures adjacent to the sinus wall, high-intensity areas in the venous sinus, and early filling of the venous sinus were 100% and 100%, 76% and 86%, and 87% and 100%, respectively. Although 3D TOF MR angiography failed to show the findings of retrograde cortical venous drainage and venous sinus occlusion, MR digital subtraction angiography clearly showed both findings in all five subjects. CONCLUSION. A protocol including both 3D TOF MR angiography (source images) and MR digital subtraction angiography allowed the diagnosis of moderate- to high-flow dural arteriovenous fistula. In addition, cortical venous drainage was reliably noted in a small subset of patients.
引用
收藏
页码:183 / 190
页数:8
相关论文
共 50 条
  • [1] Evaluation of Intracranial Dural Arteriovenous Fistulas: Comparison of Unenhanced 3T 3D Time-of-flight MR Angiography with Digital Subtraction Angiography
    Azuma, Minako
    Hirai, Toshinori
    Shigematsu, Yoshinori
    Kitajima, Mika
    Kai, Yutaka
    Yano, Shigetoshi
    Nakamura, Hideo
    Makino, Keishi
    Iryo, Yasuhiko
    Yamashita, Yasuyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2015, 14 (04) : 285 - 293
  • [2] Phase contrast MR angiography of intracranial dural arteriovenous fistulas
    Cellerini, M
    Mascalchi, M
    Ferrito, G
    Mangiafico, S
    Scazzeri, F
    Olmastroni, M
    Marin, E
    Scardigli, V
    DalPozzo, G
    Quilici, N
    RIVISTA DI NEURORADIOLOGIA, 1997, 10 : 137 - 139
  • [3] Malignant glioma - Evaluation with 3D time-of-flight MR angiography
    Kadota, T
    Nakagawa, H
    Kuroda, C
    ACTA RADIOLOGICA, 1998, 39 (03) : 227 - 232
  • [4] 3d Time-of-flight Mr Angiography At 3.0 Tesla Underestimates Disease Stage Compared To Digital Subtraction Angiography In The Evaluation Of Moyamoya Disease
    Rizvi, Ahmed
    Larson, Anthony
    Rinaldo, Lorenzo
    Klaas, James P.
    Lanzino, Giuseppe S.
    Lehman, Vance
    Meyer, Fredric
    Savastano, Luis
    Brinjikji, Waleed
    STROKE, 2022, 53
  • [5] 2D thick-section MR digital subtraction angiography for the assessment of dural arteriovenous fistulas
    Horie, N
    Morikawa, M
    Kitigawa, N
    Tsutsumi, K
    Kaminogo, M
    Nagata, I
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (02) : 264 - 269
  • [6] Assessment of Dural Arteriovenous Fistulas of the Cavernous Sinuses on 3D Dynamic MR Angiography
    Akiba, H.
    Tamakawa, M.
    Hyodoh, H.
    Hyodoh, K.
    Nonaka, T.
    Minamida, Y.
    Hashimoto, M.
    Hareyama, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (09) : 1652 - 1657
  • [7] Contrast Enhanced MR Angiography Overestimates Carotid Stenosis Compared With Time-of-Flight MR Angiography and Digital Subtraction Angiography.
    Kim, Yong Bum
    STROKE, 2019, 50
  • [8] Three-dimensional time-of-flight MR angiography for evaluation of intracranial aneurysms after endosaccular packing with Guglielmi detachable coils: comparison with 3D digital subtraction angiography
    Okahara, M
    Kiyosue, H
    Hori, Y
    Yamashita, M
    Nagatomi, H
    Mori, H
    EUROPEAN RADIOLOGY, 2004, 14 (07) : 1162 - 1168
  • [9] Three-dimensional time-of-flight MR angiography for evaluation of intracranial aneurysms after endosaccular packing with Guglielmi detachable coils: comparison with 3D digital subtraction angiography
    Mika Okahara
    Hiro Kiyosue
    Yuzo Hori
    Masanori Yamashita
    Hirofumi Nagatomi
    Hiromu Mori
    European Radiology, 2004, 14 : 1162 - 1168
  • [10] MR digital subtraction angiography for the assessment of cranial arteriovenous malformations and fistulas
    Aoki, S
    Yoshikawa, T
    Hori, M
    Nanbu, A
    Kumagai, H
    Nishiyama, Y
    Nukui, H
    Araki, T
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (02) : 451 - 453