Electrocatalytic oxidation of tyrosine at poly(threonine)-film modified carbon paste electrode and its voltammetric determination in real samples

被引:45
|
作者
Chitravathi, S. [1 ]
Swamy, B. E. Kumara [1 ]
Mamatha, G. P. [2 ]
Chandrashekar, B. N. [1 ]
机构
[1] Kuvempu Univ, Dept PG Studies & Res Ind Chem, Shankaraghatta 577451, Karnataka, India
[2] Kuvempu Univ, Dept Pharmaceut Chem, Shankaraghatta 577451, Karnataka, India
关键词
Tyrosine; Threonine; Carbon paste electrode; Cyclic voltammetry; Differential pulse voltammetry; AMINO-ACIDS; ELECTROCHEMICAL-BEHAVIOR; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; PHENYLALANINE; TRYPTOPHAN; DOPAMINE;
D O I
10.1016/j.molliq.2012.03.022
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The electrochemical behavior of tyrosine on a poly(threonine)-film modified carbon paste electrode was explored in phosphate buffer solution (pH 7.0) using cyclic voltammetric technique. Tyrosine gave an oxidation peak at 687 mV on bare CPE, whereas an oxidation peak at 671 mV with enhanced peak current was obtained on the poly(threonine)-film modified electrode showing the electrocatalytic nature of the modified electrode. Cyclic voltammetric studies indicated that the oxidation of tyrosine at the electrode surface was irreversible, adsorption controlled and involves one electron. Linear calibration plot between the oxidation peak current and the tyrosine concentration was in the range of 5 x 10(-7) to 1 x 10(-5) M and 1 x 10(-5) to 2.0 x 10(-4) M with a correlation coefficient of 0.999 and 0.997, respectively. Detection limit of tyrosine was found to be 1 x 10(-8) M by differential pulse voltammetric technique. The effect of pH and scan rate of tyrosine was studied. The analytical performance of this sensor was evaluated for the detection of tyrosine in real samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:130 / 135
页数:6
相关论文
共 50 条
  • [1] Electrocatalytic Oxidation of Dopamine on Acrylamide Modified Carbon Paste Electrode: A Voltammetric Study
    Shankar, S. Sharath
    Swamy, B. E. Kumara
    Pandurangachar, M.
    Chandra, Umesh
    Chandrashekar, B. N.
    Manjunatha, J. G.
    Sherigara, B. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (07): : 944 - 954
  • [2] Electrocatalytic oxidation and voltammetric determination of hydrazine on the tetrabromo-p-benzoquinone modified carbon paste electrode
    Raoof, Jahan-Bakhsh
    Ojani, Reza
    Ramine, Maryam
    ELECTROANALYSIS, 2007, 19 (05) : 597 - 603
  • [3] Electrocatalytic determination of sulfite using a modified carbon nanotubes paste electrode: application for determination of sulfite in real samples
    Karimi-Maleh, Hassan
    Ensafi, Ali A.
    Beitollahi, Hadi
    Nasiri, Vahid
    Khalilzadeh, Mohammad A.
    Biparva, Pourya
    IONICS, 2012, 18 (07) : 687 - 694
  • [4] Electrocatalytic determination of sulfite using a modified carbon nanotubes paste electrode: application for determination of sulfite in real samples
    Hassan Karimi-Maleh
    Ali A. Ensafi
    Hadi Beitollahi
    Vahid Nasiri
    Mohammad A. Khalilzadeh
    Pourya Biparva
    Ionics, 2012, 18 : 687 - 694
  • [5] Electrocatalytic Oxidation and Determination of Cysteamine by Poly-N,N-dimethylaniline/Ferrocyanide Film Modified Carbon Paste Electrode
    Ojani, Reza
    Raoof, Jahan-Bakhsh
    Zarei, Ebrahim
    ELECTROANALYSIS, 2009, 21 (10) : 1189 - 1193
  • [6] Electrocatalytic voltammetric determination of guanine at a cobalt phthalocyanine modified carbon nanotubes paste electrode
    Balan, Ionela
    David, Iulia Gabriela
    David, Vasile
    Stoica, Anca-Iulia
    Mihailciuc, Constantin
    Stamatin, Ioan
    Ciucu, Anton Alexandru
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 654 (1-2) : 8 - 12
  • [7] Experimental and Computational Studies on the Electrochemical Oxidation of Caffeine at Pseudo Carbon Paste Electrode and Its Voltammetric Determination in Different Real Samples
    Mersal, Gaber A. M.
    FOOD ANALYTICAL METHODS, 2012, 5 (03) : 520 - 529
  • [8] Experimental and Computational Studies on the Electrochemical Oxidation of Caffeine at Pseudo Carbon Paste Electrode and Its Voltammetric Determination in Different Real Samples
    Gaber A. M. Mersal
    Food Analytical Methods, 2012, 5 : 520 - 529
  • [9] Voltammetric determination of thiocytosine based on its electrocatalytic oxidation on the surface of carbon-paste electrode modified with cobalt Schiff base complexes
    Saeed Shahrokhian
    Mandana Amiri
    Journal of Solid State Electrochemistry, 2007, 11 : 1133 - 1138
  • [10] Voltammetric determination of thiocytosine based on its electrocatalytic oxidation on the surface of carbon-paste electrode modified with cobalt Schiff base complexes
    Shahrokhian, Saeed
    Amiri, Mandana
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2007, 11 (08) : 1133 - 1138