Liquid paraffin as new dilution medium for the analysis of high boiling point residual solvents with static headspace-gas chromatography

被引:19
|
作者
D'Autry, Ward [1 ]
Zheng, Chao [1 ]
Bugalama, John [1 ]
Wolfs, Kris [1 ]
Hoogmartens, Jos [1 ]
Adams, Erwin [1 ]
Wang, Bochu [1 ]
Van Schepdael, Ann [1 ]
机构
[1] Katholieke Univ Leuven, Lab Pharmaceut Anal, Fac Pharmaceut Sci, B-3000 Louvain, Belgium
关键词
Static headspace; Gas chromatography; Residual solvents; Dilution media; Validation; PHARMACEUTICAL PRODUCTS; PHASE MICROEXTRACTION; IONIC LIQUIDS; LIMITS; VAPOR;
D O I
10.1016/j.jpba.2011.04.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Residual solvents are volatile organic compounds which can be present in pharmaceutical substances. A generic static headspace-gas chromatography analysis method for the identification and control of residual solvents is described in the European Pharmacopoeia. Although this method is proved to be suitable for the majority of samples and residual solvents, the method may lack sensitivity for high boiling point residual solvents such as N,N-dimethylformamide, N,N-dimethylacetamide, dimethyl sulfoxide and benzyl alcohol. In this study, liquid paraffin was investigated as new dilution medium for the analysis of these residual solvents. The headspace-gas chromatography method was developed and optimized taking the official Pharmacopoeia method as a starting point. The optimized method was validated according to ICH criteria. It was found that the detection limits were below 1 mu g/vial for each compound, indicating a drastically increased sensitivity compared to the Pharmacopoeia method, which failed to detect the compounds at their respective limit concentrations. Linearity was evaluated based on the R(2) values, which were above 0.997 for all compounds, and inspection of residual plots. Instrument and method precision were examined by calculating the relative standard deviations (RSD) of repeated analyses within the linearity and accuracy experiments, respectively. It was found that all RSD values were below 10%. Accuracy was checked by a recovery experiment at three different levels. Mean recovery values were all in the range 95-105%. Finally, the optimized method was applied to residual DMSO analysis in four different Kollicoat (R) sample batches. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1017 / 1023
页数:7
相关论文
共 50 条
  • [1] RESIDUAL SOLVENTS DETERMINATION IN PHARMACEUTICALS BY STATIC HEADSPACE-GAS CHROMATOGRAPHY AND HEADSPACE LIQUID-PHASE MICROEXTRACTION GAS CHROMATOGRAPHY
    Heydari, Rouhollah
    ANALYTICAL LETTERS, 2012, 45 (13) : 1875 - 1884
  • [2] Residual solvents determination in drug products by static headspace-gas chromatography
    Camarasu, CC
    CHROMATOGRAPHIA, 2002, 56 (1) : S137 - S143
  • [3] Residual solvents determination in drug products by static headspace-gas chromatography
    C. C. Camarasu
    Chromatographia, 2002, 56 : S137 - S143
  • [4] Natural deep eutectic solvents as eco-friendly and sustainable dilution medium for the determination of residual organic solvents in pharmaceuticals with static headspace-gas chromatography
    Wang, Meilian
    Fang, Sheng
    Liang, Xianrui
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 158 : 262 - 268
  • [5] Mixed aqueous solutions as dilution media in the determination of residual solvents by static headspace gas chromatography
    D'Autry, Ward
    Zheng, Chao
    Wolfs, Kris
    Yarramraju, Sitaramaraju
    Hoogmartens, Jos
    Van Schepdael, Ann
    Adams, Erwin
    JOURNAL OF SEPARATION SCIENCE, 2011, 34 (11) : 1299 - 1308
  • [6] Room Temperature Ionic Liquid as Matrix Medium for Simultaneous Determination of Residual Solvents by Static Headspace Gas Chromatography
    Lei Li-Li
    Jiang Ye
    He Xiao-Wen
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (04) : 577 - 580
  • [7] Room temperature ionic liquid as matrix medium for the determination of residual solvents in pharmaceuticals by static headspace gas chromatography
    Liu, Feng-Hua
    Jiang, Ye
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1167 (01) : 116 - 119
  • [8] Determination of multiple residual solvents in ibandronate sodium using headspace-gas chromatography
    Zhou Ran
    Wang Fei
    Lin Jiarui
    Jia Meng
    Wang Yan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2024, 42 (05) : 481 - 486
  • [9] STATIC HEADSPACE GAS-CHROMATOGRAPHY OF RESIDUAL SOLVENTS IN PHARMACEUTICAL PRODUCTS
    RUSSO, MV
    CHROMATOGRAPHIA, 1994, 39 (11-12) : 645 - 648
  • [10] Measurement of residual solvents in thiamine hydrochloride by static headspace gas chromatography
    Song, Wenhua
    Gao, Minling
    Guo, Jing
    Sun, Ting
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,