The effect of aortic area measurement site on the energy loss coefficient: a comparison between echocardiography and cardiac computed tomography angiography in patients with aortic stenosis

被引:2
|
作者
Yaari, Dotan [1 ]
Rubinshtein, Ronen [1 ,2 ]
Sachner, Robert [3 ]
Gaspar, Tamar [1 ,3 ]
Adawi, Salim [1 ,2 ]
Jaffe, Ronen [1 ,2 ]
Asmer, Ihab [2 ]
Ganaeem, Majdi [2 ]
Shiran, Avinoam [1 ,2 ]
机构
[1] Technion Israel Inst Technol, Ruth & Bruce Rappaport Fac Med, Haifa, Israel
[2] Lady Davis Carmel Med Ctr, Dept Cardiovasc Med, Haifa, Israel
[3] Lady Davis Carmel Med Ctr, Dept Radiol, Haifa, Israel
关键词
aortic stenosis; cardiac computed tomography angiography; energy loss coefficient; energy loss index; transthoracic echocardiography; PRESSURE RECOVERY; VALVE AREA; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DOPPLER-ECHOCARDIOGRAPHY; ORIFICE AREA; RECOMMENDATIONS; PLANIMETRY; IMPACT; ULTRASOUND; GRADIENTS;
D O I
10.1111/echo.13331
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimThe energy loss coefficient (ELCo) has been suggested as a more accurate indicator of aortic stenosis (AS) severity as compared to transthoracic echocardiography (TTE) aortic valve area (AVA). There are little data regarding the optimal location for aortic area (Aa) measurement needed for ELCo calculation and the agreement of ELCo with direct anatomical AVA measurement. The aim of this study was to determine the optimal site of Aa measurement for calculation of the ELCo, using cardiac computed tomography angiography (CCTA) AVA planimetry as the reference standard. MethodsWe analyzed 69 patients with AS who underwent both CCTA and TTE. ELCo and CCTA planimetry AVA were compared using multiple sites for CCTA Aa measurement (sinus, sinotubular junction, or ascending aorta). ResultsCCTA AVA was 0.960.46cm(2). ELCo was 0.95 +/- 0.43cm(2) using sinotubular junction Aa, 0.92 +/- 0.41cm(2) using sinus Aa, and 0.91 +/- 0.4cm(2) using the ascending aorta (P=.84, P=.13, and P=.08 compared to CCTA AVA). There was good agreement between CCTA AVA and ELCo using all Aa locations (0.89-0.90). On subgroup analysis of 16 patients most likely to be affected by pressure recovery (aortic diameter<3cm and AVA 1cm(2)), ELCo using the sinotubular junction Aa showed the best agreement with CCTA AVA as compared to the other Aa locations (0.84 vs 0.75-0.77). ConclusionsELCo using Aa measurement at the sinotubular junction showed the best agreement with CCTA AVA. We therefore recommend using the sinotubular junction Aa for ELCo calculation.
引用
收藏
页码:1649 / 1655
页数:7
相关论文
共 50 条
  • [1] Dual-Source Computed Tomography Angiography in Aortic Stenosis: Comparison with Transthoracic Echocardiography
    Yaakup, Nur Adura
    Phuah, Hooi Fang
    Aziz, Yang Faridah Abdul
    Abidin, Imran Zainal
    Sun, Zhonghua
    Ng, Kwan Hoong
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (05) : 749 - 755
  • [2] Assessment of aortic valve area in aortic stenosis using cardiac magnetic resonance tomography: Comparison with echocardiography
    Malyar, Nasser M.
    Schlosser, Thomas
    Barkhausen, Joerg
    Gutersohn, Achim
    Buck, Thomas
    Bartel, Thomas
    Erbel, Raimund
    CARDIOLOGY, 2008, 109 (02) : 126 - 134
  • [3] COMPARISON OF AORTIC VALVE AREA ON COMPUTED TOMOGRAPHY VERSUS ECHOCARDIOGRAPHY
    Foley, R.
    Lyen, S.
    Manghat, N.
    Hamilton, M.
    HEART, 2020, 106 : A3 - A4
  • [4] Comparison of Aortic Annulus Size by Transesophageal Echocardiography and Computed Tomography Angiography With Direct Surgical Measurement
    Wang, Hanghang
    Hanna, Jennifer M.
    Ganapathi, Asvin
    Keenan, Jeffrey E.
    Hurwitz, Lynne M.
    Vavalle, John P.
    Kiefer, Todd L.
    Wang, Andrew
    Harrison, J. Kevin
    Hughes, G. Chad
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (11): : 1568 - 1573
  • [5] Assessment of aortic valve area on cardiac computed tomography and doppler echocardiography: differences and clinical significance in symptomatic bicuspid aortic stenosis
    Kim, K.
    Lee, S. J.
    Seo, J.
    Suh, Y. J.
    Cho, I.
    Hong, G. R.
    Ha, J. W.
    Kim, Y. J.
    Shim, C. Y.
    EUROPEAN HEART JOURNAL, 2022, 43 : 143 - 143
  • [6] Assessment of aortic valve area on cardiac computed tomography in symptomatic bicuspid aortic stenosis: Utility and differences from Doppler echocardiography
    Kim, Kyu
    Lee, Soo Ji
    Seo, Jiwon
    Suh, Young Joo
    Cho, Iksung
    Hong, Geu-Ru
    Ha, Jong-Won
    Kim, Young Jin
    Shim, Chi Young
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [7] Myocardial Evaluation in Patients with Aortic Stenosis by Cardiac Computed Tomography
    Gama, Francisco F.
    Patel, Kush
    Bennett, Jonathan
    Aziminia, Nikoo
    Pugliese, Francesca
    Treibel, Thomas
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (06): : 506 - 513
  • [8] Differences in aortic valve area measured on cardiac CT and echocardiography in patients with aortic stenosis
    Choe, Jooae
    Koo, Hyun Jung
    Choi, Se Jin
    Lee, Seung-Ah
    Kim, Dae-Hee
    Song, Jong-Min
    Kang, Duk-Hyun
    Song, Jae-Kwan
    Kang, Joon-Won
    Yang, Dong Hyun
    PLOS ONE, 2023, 18 (01):
  • [9] Comparison of Computed Tomography Angiography and Transesophageal Echocardiography for Evaluating Aortic Arch Disease
    Barazangi, Nobl
    Wintermark, Max
    Lease, Katy
    Rao, Rajni
    Smith, Wade
    Josephson, S. Andrew
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2011, 20 (05): : 436 - 442
  • [10] Clinical implication of energy loss coefficient in patients with severe aortic stenosis diagnosed by Doppler echocardiography
    Kume, Teruyoshi
    Okura, Hiroyuki
    Kawamoto, Takahiro
    Watanabe, Nozomi
    Hayashida, Akihiro
    Neishi, Yoji
    Miyamoto, Yoshinori
    Imai, Koichiro
    Yamada, Ryotaro
    Yoshida, Kiyoshi
    CIRCULATION JOURNAL, 2008, 72 (08) : 1265 - 1269