Further developments in the use of semipermeable membrane devices (SPMDs) as passive air samplers for persistent organic pollutants: Field application in a spatial survey of PCDD/Fs and PAHs

被引:82
|
作者
Lohmann, R [1 ]
Corrigan, BP [1 ]
Howsam, M [1 ]
Jones, KC [1 ]
Ockenden, WA [1 ]
机构
[1] Univ Lancaster, Div Environm Sci, Lancaster LA1 4YQ, England
关键词
D O I
10.1021/es0001862
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Semipermeable membrane devices (SPMDs) were deployed at 19 sites in northwest England to test their efficacy as passive atmospheric samplers for polychlorinated dibenzo-p-dioxins and -furans (PCDD/Fs) and polycyclic aromatic hydrocarbons (PAHs). SPMDs were found to be efficient samplers for vapor phase species in the atmosphere, with good reproducibility between samplers. Species which are partially or completely particle associated under ambient U.K. conditions were also sampled by the SPMDs but with poorer reproducibility. it is suggested that SPMDs could be used to indicate "hot-spots" of particulate associated species, however. Differences in absolute and relative concentrations of all PCDD/Fs and PAHs sequestered by the SPMDs were observed between sites. High amounts were sequestered in SPMDs at sites where previous active monitoring has indicated relatively high atmospheric concentrations, confirming the potential of SPMDs as a tool for semiquantitative spatial monitoring of atmospheric species. SPMDs also respond to differences in the mixture of compounds present in the atmosphere, thereby aiding source apportionment studies.
引用
收藏
页码:2576 / 2582
页数:7
相关论文
共 7 条
  • [1] Further developments in the use of semipermeable membrane devices as passive air samplers: Application to PCBs
    Ockenden, WA
    Corrigan, BP
    Howsam, M
    Jones, KC
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (22) : 4536 - 4543
  • [2] APPLICATION OF SEMIPERMEABLE-MEMBRANE DEVICES (SPMDS) AS PASSIVE AIR SAMPLERS
    PETTY, JD
    HUCKINS, JN
    ZAJICEK, JL
    CHEMOSPHERE, 1993, 27 (09) : 1609 - 1624
  • [3] Field-based evaluation of semipermeable membrane devices (SPMDs) as passive air samplers of polyaromatic hydrocarbons (PAHs)
    Bartkow, ME
    Huckins, JN
    Müller, JF
    ATMOSPHERIC ENVIRONMENT, 2004, 38 (35) : 5983 - 5990
  • [4] The use of semipermeable determine persistent membrane devices as passive samplers to organic compounds in indoor air
    Strandberg, B
    Gustafson, P
    Söderström, H
    Barregard, L
    Bergqvist, PA
    Sällsten, G
    JOURNAL OF ENVIRONMENTAL MONITORING, 2006, 8 (02): : 257 - 262
  • [5] Toward an understanding of the global atmospheric distribution of persistent organic pollutants: The use of semipermeable membrane devices as time-integrated passive samplers
    Ockenden, WA
    Sweetman, AJ
    Prest, HF
    Steinnes, E
    Jones, KC
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (18) : 2795 - 2803
  • [6] Field use of semipermeable membrane devices (SPMDs) for passive air sampling of polycyclic aromatic hydrocarbons: Opportunities and limitations
    Piccardo, M. T.
    Stella, A.
    Pala, M.
    Balducci, D.
    Valerio, F.
    ATMOSPHERIC ENVIRONMENT, 2010, 44 (16) : 1947 - 1951
  • [7] Survey of persistent organic pollutants (POPs) and polycyclic aromatic hydrocarbons (PAHs) in the atmosphere of rural, urban and industrial areas of Concepcion, Chile, using passive air samplers
    Pozo, Karla
    Harner, Tom
    Rudolph, Anny
    Oyola, German
    Estellano, Victor H.
    Ahumada-Rudolph, Ramon
    Garrido, Mauricio
    Pozo, Katerine
    Mabilia, Rosanna
    Focardi, Silvano
    ATMOSPHERIC POLLUTION RESEARCH, 2012, 3 (04) : 426 - 434