Experimental investigations on the load-carrying capacity of digitally produced wood-wood connections

被引:13
|
作者
Gamerro, Julien [1 ]
Bocquet, Jean Francois [2 ]
Weinand, Yves [1 ]
机构
[1] Ecole Polytech Fed Lausanne EPFL, Inst Civil Engn IIC, Lab Timber Construct IBOIS, Sch Architecture Civil & Environm Engn MAC, GC H2 711,Stn 18, CH-1015 Lausanne, Switzerland
[2] Ecole Natl Super Technol & Ind Bois ENSTIB, Lab Studies & Res Wood Mat LERMAB, 27 Rue Philippe Seguin CS60036, F-88026 Epinal, France
基金
瑞士国家科学基金会;
关键词
Digital fabrication; Timber structures; Timber joints; Wood-wood connections; Load-carrying capacity; Shear test; Compression test; Design guidelines; CLT BRACING ELEMENTS; TIMBER;
D O I
10.1016/j.engstruct.2020.110576
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The rise of digital fabrication has increased the use of wood-wood connections inspired by traditional carpentry in modern timber constructions. With recent developments on standard construction systems, the mechanical behavior of such joints for in-plane loading configurations is an essential parameter for the structural design. However, only few design guidelines exist on this topic in building codes such as Eurocode 5 and research has been mainly focused on the rotational behavior, which is important for free-form structures. Therefore, this work presents an experimental campaign on the load-carrying capacity of digitally produced through tenon connections for commonly available engineered timber products such as oriented strand board, laminated veneer lumber, and multiply solid wood panels. Shear and compression failure modes were studied and two test setups were developed. The scope of the study was limited to five different materials, a grain orientation parallel to the joint, and three different tenon lengths. The test results showed significant differences between the product specifications given by manufacturers and real performances observed for oriented strand board and cross laminated timber, while laminated veneer lumber had more accurate specifications. Nonetheless, a spreading of the compression strength was highlighted only for the OSB material and was also observed for the shear strength of laminated veneer lumber specimens. The existing Eurocode 5 guidelines generally underestimated the load-carrying capacity of the connections by 25% and only the capacity of oriented strand board connections was overestimated. Finally, the study demonstrates that different design approaches can be defined according to the material employed in through tenon connections. Design diagrams based on tests are preferred for materials with a high variability between product specifications and real performances while design criteria from building codes can be applied for the others.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Wood Load-Carrying Capacity of Timber Connections: An Extended Application for Nails and Screws
    Zarnani, Pouyan
    Quenneville, Pierre
    MATERIALS AND JOINTS IN TIMBER STRUCTURES: RECENT DEVELOPMENTS OF TECHNOLOGY, 2014, 9 : 167 - 179
  • [2] LOAD-CARRYING EFFICIENCY OF HOMOGENEOUS WOOD COMPOSITES
    BODIG, J
    WOOD AND FIBER, 1979, 10 (03): : 188 - 199
  • [3] LOAD-CARRYING CAPACITY OF HYBRID STEEL-WOOD-STEEL DOWEL CONNECTIONS IN DOUBLE-SHEAR UNDER FIRE
    Fonseca, Elza M. M.
    Silva, Vania
    Piloto, Paulo A. G.
    7TH INTERNATIONAL CONFERENCE INTEGRITY-RELIABILITY-FAILURE (IRF2020), 2020, : 557 - 562
  • [4] Experimental and Numerical Investigations of the Influence of Reinforcement on the Load-Carrying Capacity of Ice Crossings
    Zemlyak, V. L.
    Kozin, V. M.
    Vasil'ev, A. S.
    Ipatov, K. I.
    SOIL MECHANICS AND FOUNDATION ENGINEERING, 2019, 56 (01) : 37 - 43
  • [5] Experimental and Numerical Investigations of the Influence of Reinforcement on the Load-Carrying Capacity of Ice Crossings
    V. L. Zemlyak
    V. M. Kozin
    A. S. Vasil’ev
    K. I. Ipatov
    Soil Mechanics and Foundation Engineering, 2019, 56 : 37 - 43
  • [6] INVESTIGATIONS OF CALCULATION AND INCREASING OF LOAD-CARRYING CAPACITY AT GEARS
    FRONIUS, S
    LINKE, H
    MASCHINENBAUTECHNIK, 1973, 22 (11): : 483 - 491
  • [7] Load-Carrying Capacity and Stiffness of Softwood Wooden Dowel Connections
    Frontini, Filippo
    Siem, Jan
    Renmaelmo, Roald
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2020, 14 (03) : 376 - 397
  • [8] Wood-concrete and wood-wood mixed beams:: Rational basis for selecting connections
    Fernandez-Cabo, Jos L.
    Fernandez-Lavandera, Jorge
    Avila-Jalvo, Jose M.
    JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (03) : 440 - 447
  • [9] Load-Carrying Capacity of Lengthwise Cracked Wood Beams Retrofitted by Self-Tapping Screws
    Song, Xiaobin
    Jiang, Yingmin
    Gu, Xianglin
    Wu, Yajie
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (06)
  • [10] A Calculation Method for Interconnected Timber Elements Using Wood-Wood Connections
    Gamerro, Julien
    Bocquet, Jean Francois
    Weinand, Yves
    BUILDINGS, 2020, 10 (03)