Occurrence and Persistency of Conduction Disturbances during Transcatheter Aortic Valve Implantation

被引:4
|
作者
Poels, Thomas T. [1 ]
Engels, Elien B. [2 ]
Kats, Suzanne [1 ]
Veenstra, Leo [3 ]
van Ommen, Vincent [3 ]
Vernooy, Kevin [3 ]
Maessen, Jos G. [1 ]
Prinzen, Frits W. [2 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Cardiothorac Surg, POB 5800, Maastricht, Netherlands
[2] CARIM Sch Cardiovasc Dis, Fac Hlth Med & Life Sci, Dept Physiol, POB 616, Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Cardiol, POB 5800, Maastricht, Netherlands
来源
MEDICINA-LITHUANIA | 2021年 / 57卷 / 07期
关键词
transcatheter aortic valve implantation; left bundle branch block; electrocardiogram; BUNDLE-BRANCH BLOCK; PERMANENT PACEMAKER IMPLANTATION; ATRIOVENTRICULAR-BLOCK; GAP-JUNCTIONS; COREVALVE PROSTHESIS; HIS-BUNDLE; PREDICTORS; ABNORMALITIES; REPLACEMENT; STENOSIS;
D O I
10.3390/medicina57070695
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: Conduction disturbances such as left bundle branch block (LBBB) and complete atrio-ventricular block (cAVB) are relatively frequent complications following trans-catheter aortic valve implantation (TAVI). We investigated the dynamics of these conduction blocks to further understand luxating factors and predictors for their persistency. Materials and Methods: We prospectively included 157 consecutive patients who underwent a TAVI procedure. Electrocardiograms (ECGs) were obtained at specific time points during the TAVI procedure and at follow-up until at least six months post-procedure. Results: Of the 106 patients with a narrow QRS complex (nQRS) before TAVI, similar to 70% developed LBBB; 28 (26.4%) being classified as super-transient (ST-LBBB), 20 (18.9%) as transient (T-LBBB) and 24 (22.6%) as persistent (P-LBBB). Risk of LBBB was higher for self-expandable (SE) than for balloon-expandable (BE) prostheses and increased with larger implant depth. During the TAVI procedure conduction disturbances showed a dynamic behavior, as illustrated by alternating kinds of blocks in 18 cases. Most LBBBs developed during balloon aortic valvuloplasty (BAV) and at positioning and deployment of the TAVI prosthesis. The incidence of LBBB was not significantly different between patients who did and did not undergo BAV prior to TAVI implantation (65.3% and 74.2%, respectively (p = 0.494)). Progression to cAVB was most frequent for patients with preexisting conduction abnormalities (5/34) patients) and in patients showing ST-LBBB (6/28). Conclusions: During the TAVI procedure, conduction disturbances showed a dynamic behavior with alternating types of block in 18 cases. After a dynamic period of often alternating types of block, most BBBs are reversible while one third persist. Patients with ST-LBBB are most prone to progressing into cAVB. The observation that the incidence of developing LBBB after TAVI is similar with and without BAV suggests that a subgroup of patients has a substrate to develop LBBB regardless of the procedure.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Pathophysiology, incidence and predictors of conduction disturbances during Transcatheter Aortic Valve Implantation
    Barbanti, Marco
    Gulino, Simona
    Costa, Giuliano
    Tamburino, Corrado
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (02) : 135 - 147
  • [2] Influence of deep implantation on conduction disturbances after transcatheter aortic valve implantation
    Saad M.
    Klaus Y.
    Buhse P.
    Puehler T.
    Lutter G.
    Seoudy H.
    Frank D.
    Herzschrittmachertherapie + Elektrophysiologie, 2021, 32 (3) : 371 - 379
  • [3] Transcatheter Aortic Valve Implantation and Conduction Disturbances: Focus on Clinical Implications
    Halapas, Antonios
    Koliastasis, Leonidas
    Doundoulakis, Ioannis
    Antoniou, Christos-Konstantinos
    Stefanadis, Christodoulos
    Tsiachris, Dimitrios
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (11)
  • [4] Steroid therapy and conduction disturbances after transcatheter aortic valve implantation
    Havakuk, Ofer
    Konigstein, Maayan
    Ben Assa, Eyal
    Arbel, Yaron
    Abramowitz, Yigal
    Halkin, Amir
    Bazan, Samuel
    Shmilovich, Haim
    Keren, Gad
    Finkelstein, Ariel
    Banai, Shmuel
    CARDIOVASCULAR THERAPEUTICS, 2016, 34 (05) : 325 - 329
  • [5] Prognostic impact of intraventricular conduction disturbances after transcatheter aortic valve implantation
    Almeida, J.
    Dias, T.
    Guerreiro, C.
    Pereira, E.
    Caeiro, D.
    Oliveira, M.
    Goncalves, H.
    Rodrigues, A.
    Ribeiro, J.
    Primo, J.
    Braga, P.
    Gama, V.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1074 - 1074
  • [6] Conduction disturbances after transcatheter aortic valve implantation procedures - predictors and management
    Wilczek, Krzysztof
    Regula, Rafal
    Bujak, Kamil
    Chodor, Piotr
    Dlugaszek, Michal
    Gasior, Mariusz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2016, 12 (03): : 203 - 211
  • [7] Conduction disturbances following transcatheter aortic valve implantation: Any room for improvement?
    Charitos, Efstratios
    Kim, Won-Keun
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2022, 354 : 41 - 42
  • [8] Trends in the Occurrence of New Conduction Abnormalities After Transcatheter Aortic Valve Implantation
    van der Boon, Robert M. A.
    Houthuizen, Patrick
    Urena, Marina
    Poels, Thomas T.
    van Mieghem, Nicolas M.
    Brueren, Guus R. G.
    Altintas, Sibel
    Nuis, Rutger Jan
    Serruys, Patrick W.
    van Garsse, Leen A. F. M.
    van Domburg, Ron T.
    Cabau, Joseph Rodes
    de Jaegere, Peter P. T.
    Prinzen, Frits W.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (05) : 144 - 152
  • [9] Impact of High Implantation of Transcatheter Aortic Valve on Subsequent Conduction Disturbances and Coronary Access
    Ochiai, Tomoki
    Yamanaka, Futoshi
    Shishido, Koki
    Moriyama, Noriaki
    Komatsu, Ikki
    Yokoyama, Hiroaki
    Miyashita, Hirokazu
    Sato, Daisuke
    Sugiyama, Yoichi
    Hayashi, Takahiro
    Yamashita, Takayoshi
    Tobita, Kazuki
    Matsumoto, Takashi
    Mizuno, Shingo
    Tanaka, Yutaka
    Murakami, Masato
    Takahashi, Saeko
    Makkar, Raj
    Saito, Shigeru
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (10) : 1192 - 1204
  • [10] Frequency of Conduction Disturbances After Transcatheter Implantation of an Edwards Sapien Aortic Valve Prosthesis
    Godin, Matthieu
    Eltchaninoff, Helene
    Furuta, Akira
    Tron, Christophe
    Anselme, Frederic
    Bejar, Karim
    Sanchez-Giron, Carlos
    Bauer, Fabrice
    Litzler, Pierre-Yves
    Bessou, Jean-Paul
    Cribier, Alain
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (05): : 707 - 712