Energy use and thermal comfort in a rammed earth office building

被引:84
|
作者
Taylor, P. [1 ]
Fuller, R. J. [2 ]
Luther, M. B. [2 ]
机构
[1] Charles Sturt Univ, Div Facil Management, Albury, NSW 2640, Australia
[2] Deakin Univ, Sch Architecture & Bldg, Built Environm Res Grp, Geelong, Vic 3217, Australia
关键词
rammed earth; thermal comfort; energy; office building;
D O I
10.1016/j.enbuild.2007.05.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A two-storey rammed earth building was built on the Thurgoona Campus of Charles Sturt University in Albury-Wodonga, Australia, in 1999. The building is novel both in the use of materials and equipment for heating and cooling. The climate at Wodonga can be characterised as hot and dry, so the challenge of providing comfortable working conditions with minimal energy consumption is considerable. This paper describes an evaluation of the building in terms of measured thermal comfort and energy use. Measurements, confirmed by a staff questionnaire, found the building was too hot in summer and too cold in winter. Comparison with another office building in the same location found that the rammed earth building used more energy for heating. The thermal performance of three offices in the rammed earth building was investigated further using simulation to predict office temperatures. Comparisons were made with measurements made over typical weeks in summer and winter. The validated model has been used to investigate key building parameters and strategies to improve the thermal comfort and reduce energy consumption in the building. Simulations showed that improvements could be made by design and control strategy changes. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:793 / 800
页数:8
相关论文
共 50 条
  • [1] Evaluation of the Thermal Comfort and Energy Demand in a Building with Rammed Earth Walls in Spain: Influence of the Use of In Situ Measured Thermal Conductivity and Estimated Values
    Mascaraque, Miguel Angel Mellado
    Pascual, Francisco Javier Castilla
    Andreu, Victor Perez
    Guenot, Guillermo Adrian Gosalbo
    BUILDINGS, 2021, 11 (12)
  • [2] Optimisation of energy performance and thermal comfort of an office building
    Solmaz, Aslihan Senel
    GRADEVINAR, 2018, 70 (07): : 581 - 592
  • [3] An Energy Efficiency Assessment of the Thermal Comfort in an Office building
    Zhao, Zhidan
    Houchati, Mahdi
    Beitelmal, AbdlMonem
    SUSTAINABILITY IN ENERGY AND BUILDINGS 2017, 2017, 134 : 885 - 893
  • [4] Energy Use and Thermal Performance of Rammed-Earth Materials
    Samadianfard, Sima
    Toufigh, Vahab
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2020, 32 (10)
  • [5] Rammed Earth Building: Contribution of Moisture Transfer on Indoor Comfort
    Poupard, Theo
    Fabre, Florent
    Poullain, Philippe
    Issaadi, Nabil
    Bonnet, Stephanie
    SECOND RILEM INTERNATIONAL CONFERENCE ON EARTHEN CONSTRUCTION, ICEC 2024, 2024, 52 : 184 - 193
  • [6] Thermal comfort evaluation of a Rammed Earth residential building: case study: Yazd city in Iran
    Khadjavian, Sara
    Mahdavinia, Mojtaba
    Farahza, Nariman
    Yazdi, Hamid Rezaeian
    ADVANCES IN BUILDING ENERGY RESEARCH, 2025, 19 (01) : 113 - 135
  • [7] Building Energy Use Modes and Thermal Comfort
    Amasyali, Kadir
    El-Gohary, Nora
    COMPUTING IN CIVIL ENGINEERING 2017: INFORMATION MODELLING AND DATA ANALYTICS, 2017, : 350 - 358
  • [8] Energy and thermal performance of a typical rammed earth residential building in Western Australia
    Strazzeri, Vittoria
    Karrech, Ali
    Energy and Buildings, 2022, 260
  • [9] A field study on thermal comfort and air-conditioning energy use in an office building in Guangzhou
    Wu, Tongling
    Cao, Bin
    Zhu, Yingxin
    ENERGY AND BUILDINGS, 2018, 168 : 428 - 437
  • [10] Energy and thermal performance of a typical rammed earth residential building in Western Australia
    Strazzeri, Vittoria
    Karrech, Ali
    ENERGY AND BUILDINGS, 2022, 260