Needle Detection in Ultrasound Images using Ultrasound Beamformed RF Signals

被引:0
|
作者
Daoud, Mohammad, I [1 ]
Abuhani, Ayah [1 ]
Zayadeen, Adnan R.
Alazrai, Rami [1 ]
机构
[1] German Jordanian Univ, Dept Comp Engn, Amman, Jordan
关键词
ultrasound imaging; ultrasound-guided needle interventions; needle detection; ultrasound signal processing; LOCALIZATION;
D O I
10.1109/ICEEE52452.2021.9415947
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Medical ultrasound imaging is used in many image-guided needle interventions to visualize the patient anatomy and the advancing needle. Despite the improved capability of ultrasound to visualize the patient anatomy, detecting the needle in ultrasound images is often a difficult task. Many methods were introduced to detect the needle in ultrasound images. However, most of these methods employed ultrasound B-mode image analysis to detect the needle. Hence, the accuracy of these methods might be degraded by the limited visibility of the needle in ultrasound B-mode images, particularly at steep insertion angles. This study introduces an effective method to accurately detect the needle in ultrasound images based on the beamformed radio frequency (RF) signals that are recorded during conventional ultrasound imaging procedures. In particular, the beamformed RF signals are processed to identify the needle echoes using two signature-based features. The identified needle echoes are analyzed using the Robust Model Fitting Random Sample Consensus (RANSAC) algorithm to detect the needle trajectory. Moreover, the needle tip is detected using a moving window procedure that quantifies the variations of the beamformed RF signals around the needle trajectory. The performance of the proposed method is evaluated by detecting the trajectories and tips of biopsy needles inserted in bovine liver tissue specimens at different insertion angles. The results show that the proposed method was able to detect the needles with needle angular deviations between 0.2. and 0.6. and needle tip deviations between 0.3 to 0.5 mm. Furthermore, the results indicate that the proposed method was able to outperform a recently introduced needle detection method. These results suggest the feasibility of employing the proposed method to achieve accurate needle detection during ultrasound-guided needle interventions.
引用
收藏
页码:327 / 331
页数:5
相关论文
共 50 条
  • [1] Reliable and accurate needle localization in curvilinear ultrasound images using signature-based analysis of ultrasound beamformed radio frequency signals
    Daoud, Mohammad, I
    Abu-Hani, Ayah F.
    Alazrai, Rami
    MEDICAL PHYSICS, 2020, 47 (06) : 2356 - 2379
  • [2] Detection and Tracking of the Biopsy Needle Using Ultrasound Images
    Wijata, Agata
    Ranosz, Zaneta
    Galinska, Marta
    Juszczyk, Jan
    Czajkowska, Joanna
    INNOVATIONS IN BIOMEDICAL ENGINEERING, 2018, 623 : 33 - 41
  • [3] Enhanced Needle Detection in Ultrasound Images using Acoustic Excitation and Ultrasound Image Analyses
    Daoud, Mohammad I.
    Shtaiyat, Ahmad
    Alazrai, Rami
    2018 11TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2018), 2018,
  • [4] Pre-beamformed RF signal reconstruction in medical ultrasound using compressive sensing
    Liebgott, Herve
    Prost, Remy
    Friboulet, Denis
    ULTRASONICS, 2013, 53 (02) : 525 - 533
  • [5] Needle detection in curvilinear ultrasound images based on the reflection pattern of circular ultrasound waves
    Daoud, Mohammad I.
    Rohling, Robert N.
    Salcudean, Septimiu E.
    Abolmaesumi, Purang
    MEDICAL PHYSICS, 2015, 42 (11) : 6221 - 6233
  • [6] Detection of prostate cancer from RF ultrasound echo signals using fractal analysis
    Moradi, Mehdi
    Abolmaesumi, Purang
    Isotalo, Phillip A.
    Siemens, David R.
    Sauerbrei, Eric E.
    Mousavi, Parvin
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 785 - 788
  • [7] An Automatic Biopsy Needle Detection and Segmentation on Ultrasound Images Using a Convolutional Neural Network
    Wijata, Agata
    Andrzejewski, Jacek
    Pycinski, Bartlomiej
    ULTRASONIC IMAGING, 2021, 43 (05) : 262 - 272
  • [8] A Study of Coronary Intravascular Ultrasound Rf Signals Using Wavelets
    Samuel, Anil
    Kirsner, Richard
    Cameron, James
    Tay, David
    Meredith, Ian
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 937 - +
  • [9] Detection of pathologic liver using ultrasound images
    Santos, Jaime
    Silva, Jose Silvestre
    Santos, Andreia Andrade
    Belo-Soares, Pedro
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2014, 14 : 248 - 255
  • [10] Elimination of therapeutic ultrasound noise from pre-beamformed RF data in ultrasound imaging for ultrasound-guided high-intensity focused ultrasound treatment
    Takagi, Ryo
    Goto, Kota
    Jimbo, Hayato
    Matsuura, Keiko
    Iwasaki, Ryosuke
    Umemura, Shin-ichiro
    Yoshizawa, Shin
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2015, 54 (07)