The influence of pelvic tilt on stress distribution in the acetabulum: finite element analysis

被引:8
|
作者
Hasegawa, Kazuhiro [1 ]
Kabata, Tamon [2 ]
Kajino, Yoshitomo [2 ]
Inoue, Daisuke [2 ]
Sakamoto, Jiro [3 ]
Tsuchiya, Hiroyuki [2 ]
机构
[1] Suzu Gen Hosp, Dept Orthopaed Surg, 1-1 Nonoemati, Suzu, Ishikawa 9271213, Japan
[2] Kanazawa Univ, Grad Sch Med Sci, Dept Orthopaed Surg, 13-1 Takaramachi, Kanazawa, Ishikawa 9208641, Japan
[3] Kanazawa Univ, Sch Mech Engn, Bio Engn Lab, Kanazawa, Ishikawa 9201192, Japan
关键词
Finite element analysis; Osteoarthritis; Pelvic tilt; Acetabular dysplasia; HIP; DYSPLASIA; OSTEOARTHROSIS; OSTEOTOMY; COVERAGE; FRACTURE; JOINT;
D O I
10.1186/s12891-021-04500-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Finite element analysis (FEA) has been previously applied for the biomechanical analysis of acetabular dysplasia and osteotomy. However, until now, there have been little reports on the use of FEA to evaluate the effects of pelvic tilt on stress distribution in the acetabulum. Methods We used the Mechanical Finder Ver. 7.0 (RCCM, Inc., Japan) to construct finite element models based on 3D-CT data of patients, and designed dysplasia, borderline, and normal pelvic models. For analysis, body weight was placed on the sacrum and the load of the flexor muscles of the hip joint was placed on the ilium. The pelvic tilt was based on the anterior pelvic plane, and the pelvic tilt angles were -20 degrees, 0 degrees, and 20 degrees. The load of the flexor muscle of the hip joint was calculated using the moment arm equation. Results All three models showed the highest values of von Mises stress in the -20 degrees pelvic tilt angle, and the lowest in the 20 degrees angle. Stress distribution concentrated in the load-bearing area. The maximum values of von Mises stress in the borderline at pelvic tilt angles of -20 degrees was 3.5Mpa, and in the dysplasia at pelvic tilt angles of 0 degrees was 3.1Mpa. Conclusions The pelvic tilt angle of -20 degrees of the borderline model showed equal maximum values of von Mises stress than the dysplasia model of pelvic tilt angle of 0 degrees, indicating that pelvic retroversion of -20 degrees in borderline is a risk factor for osteoarthritis of the hip joints, similar to dysplasia.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] The influence of pelvic tilt on stress distribution in the acetabulum: finite element analysis
    Kazuhiro Hasegawa
    Tamon Kabata
    Yoshitomo Kajino
    Daisuke Inoue
    Jiro Sakamoto
    Hiroyuki Tsuchiya
    BMC Musculoskeletal Disorders, 22
  • [2] Effect of sagittal pelvic tilt on joint stress distribution in hip dysplasia: A finite element analysis
    Kitamura, Kenji
    Fujii, Masanori
    Utsunomiya, Takeshi
    Iwamoto, Miho
    Ikemura, Satoshi
    Hamai, Satoshi
    Motomura, Goro
    Todo, Mitsugu
    Nakashima, Yasuharu
    CLINICAL BIOMECHANICS, 2020, 74 : 34 - 41
  • [3] Influence of implant length and diameter on stress distribution:: A finite element analysis
    Himmlová, L
    Dostálová, T
    Kácovsky, A
    Konvicková, S
    JOURNAL OF PROSTHETIC DENTISTRY, 2004, 91 (01): : 20 - 25
  • [4] THE INFLUENCE OF GEOMETRY ON THE STRESS-DISTRIBUTION IN JOINTS - A FINITE-ELEMENT ANALYSIS
    ECKSTEIN, F
    MERZ, B
    SCHMID, P
    PUTZ, R
    ANATOMY AND EMBRYOLOGY, 1994, 189 (06): : 545 - 552
  • [5] Finite Element Analysis of the Influence of Geometry and Design of Zirconia Crowns on Stress Distribution
    Anami, Lilian Costa
    da Costa Lima, Julia Magalhaes
    Corazza, Pedro Henrique
    Colauto Yamamoto, Eron Toshio
    Bottino, Marco Antonio
    Souto Borges, Alexandre Luiz
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (02): : 146 - 151
  • [6] Influence of Orbital Implant Length and Diameter on Stress Distribution: A Finite Element Analysis
    Xing, Zhang
    Chen, Ling Song
    Peng, Wei
    Chen, Ling Jian
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (02) : E117 - E120
  • [7] Influence of Implant Length, Diameter, and Geometry on Stress Distribution: A Finite Element Analysis
    Anitua, Eduardo
    Tapia, Raul
    Luzuriaga, Felipe
    Orive, Gorka
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2010, 30 (01) : 89 - 95
  • [8] Finite Element Analysis of the Influence of Implant Inclination on Stress Distribution in Mandibular Overdentures
    Ebadian, Behnaz
    Mosharraf, Ramin
    Khodaeian, Niloufar
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (03) : 252 - 257
  • [9] Stress Distribution of Dental Posts by Finite Element Analysis
    Liu, P. H.
    Jhong, G. H.
    5TH KUALA LUMPUR INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING 2011 (BIOMED 2011), 2011, 35 : 219 - 221
  • [10] Stress distribution in dentin by finite element analysis.
    Vasconcellos, WA
    Campos, TM
    Cimini, CA
    Albuquerque, RC
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B126 - B126