Effect of a porous tantalum rod on early and intermediate stages of necrosis of the femoral head

被引:40
|
作者
Liu, Guohui [1 ]
Wang, Jing [1 ]
Yang, Shuhua [1 ]
Xu, Weihua [1 ]
Ye, Shunan [1 ]
Xia, Tian [1 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Orthoped, Union Hosp, Tongji Med Coll, Wuhan 430022, Peoples R China
关键词
CORE DECOMPRESSION; AVASCULAR NECROSIS; MECHANICAL-PROPERTIES; EARLY OSTEONECROSIS; BONE; HIP; ARTHROPLASTY; SURVIVAL; FIBULA;
D O I
10.1088/1748-6041/5/6/065003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to evaluate the effect of a porous tantalum rod implant for the treatment of early femoral head necrosis. From April 2007 to June 2009, a total of 35 femoral head necrosis patients (with 49 hips) were treated with core decompression in combination with the insertion of a porous tantalum rod. The mean age was 38.2 years (22-50 years) and the mean follow-up period was 15.2 months (12-36 months). The surgical time and blood loss were recorded. The Harris hip scores and radiological results were adopted for evaluation. The mean surgical time was 35 min, and the mean blood loss was 50 ml. The mean Harris score improved from 48.3 +/- 3.2 preoperative to 83.7 +/- 4.1 at the last follow-up (p < 0.05). Eight affected hips exhibited progressive pain including three hips that progressed to femoral collapse, and one revision followed by total hip arthroplasty (THA). For the patient who underwent revision and THA, the articular cartilage surface was seen to be damaged and fragmented. High-density metal particle residuals were observed on radiograph in the bone channel and femoral marrow cavity. We conclude that the selection criteria for porous tantalum implants should be early and intermediate stages of femoral head necrosis. Further study is warranted to reveal whether the metal particles released play a role in the progression of pain and failure.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Treating avascular necrosis of the femoral head with porous coating tantalum rod system
    Leng Ping
    Wang Ying-zhen
    Zhang Hai-ning
    MEDICAL MATERIALS AND ENGINEERING, 2012, 5 : 8 - 11
  • [2] Modified porous tantalum rod technique for the treatment of femoral head osteonecrosis
    Pakos, Emilios E.
    Megas, Panayiotis
    Paschos, Nikolaos K.
    Syggelos, Spyridon A.
    Kouzelis, Antonios
    Georgiadis, Georgios
    Xenakis, Theodoros A.
    WORLD JOURNAL OF ORTHOPEDICS, 2015, 6 (10): : 829 - 837
  • [3] Porous tantalum rod implant is an effective and safe choice for early-stage femoral head necrosis: A meta-analysis of clinical trials
    Zhang Y.
    Li L.
    Shi Z.-J.
    Wang J.
    Li Z.-H.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (2) : 211 - 217
  • [4] Outcome after a new porous tantalum rod implantation for treatment of early-stage femoral head osteonecrosis
    Huang, Wei
    Gong, Xuan
    Sandiford, Steve
    He, Xiaoqiang
    Li, Feilong
    Li, Yuwan
    Liu, Ziming
    Qin, Leilei
    Yang, Jianye
    Zhu, Sizheng
    Wang, Jiawei
    Tu, Xiaolin
    Ye, Lei
    Hu, Ning
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (18)
  • [5] Repair of non-traumatic femoral head necrosis by marrow core decompression with bone grafting and porous tantalum rod implantation
    Peng, Keyun
    Wang, Yu
    Zhu, Jifeng
    Li, Chengling
    Wang, Ziming
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2020, 36 (06) : 1392 - 1396
  • [6] EFFECT OF CORE DECOMPRESSION IN EARLY STAGES OF SOCALLED IDIOPATHIC NECROSIS OF THE FEMORAL-HEAD
    LEDER, K
    KNAHR, K
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1993, 131 (02): : 113 - 119
  • [7] Application of Porous Tantalum in Osteonecrosis of the Femoral Head
    Yang, Guofu
    SCIENCE OF ADVANCED MATERIALS, 2021, 13 (10) : 1976 - 1982
  • [8] Hip-preserving methods in the early stages of avascular necrosis of the femoral head
    Koca, Kenan
    Akpancar, Serkan
    Tatar, Oner
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2016, 67 (04) : 183 - 191
  • [9] Porous tantalum rods for treating osteonecrosis of the femoral head
    Liu, Z. H.
    Guo, W. S.
    Li, Z. R.
    Cheng, L. M.
    Zhang, Q. D.
    Yue, D. B.
    Shi, Z. C.
    Wang, B. L.
    Sun, W.
    Zhang, N. F.
    GENETICS AND MOLECULAR RESEARCH, 2014, 13 (04) : 8342 - 8352
  • [10] The tantalum screw for treating femoral head necrosis: rationale and results
    Aldegheri, R.
    Taglialavoro, G.
    Berizzi, A.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2007, 2 (2-3): : 63 - 68