Totally normothermic aortic arch replacement without circulatory arrest

被引:16
|
作者
Touati, GD [1 ]
Roux, N
Carmi, D
Degandt, A
Benamar, A
Marticho, P
Nzomvuama, A
Poulain, HJ
机构
[1] CHU Amiens, Hop Sud, Dept Cardiovasc Surg, F-80054 Amiens 01, France
[2] CHU Amiens, Hop Sud, Dept Anesthesiol, F-80054 Amiens, France
来源
ANNALS OF THORACIC SURGERY | 2003年 / 76卷 / 06期
关键词
D O I
10.1016/S0003-4975(03)00739-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The authors propose a new strategy of normothermic perfusion for replacement of the aortic arch to avoid the complications of profound hypothermic circulatory arrest. Six patients underwent complete replacement of the aortic arch under normothermia using two pumps for the body (one for the brain and the thoracoabdominal aortic branches) and one for the heart. The surgical procedure was performed with no time limit. There were no operative or late deaths. No patients had neurologic deficit and all were rapidly extubated with uneventful postoperative courses. The method preserves autoregulation of cerebral blood flow and maintains body perfusion without high vascular resistances. (C) 2003 by The Society of Thoracic Surgeons.
引用
收藏
页码:2115 / 2117
页数:3
相关论文
共 50 条
  • [1] Totally normothermic aortic arch replacement without circulatory arrest
    Touati, Gilles D.
    Marticho, Paul
    Farag, Moataz
    Carmi, Doron
    Szymanski, Catherine
    Barry, Misbaou
    Trojette, Faouzi
    Caus, Thierry
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 32 (02) : 263 - 267
  • [2] Totally normothermic aortic arch replacement without circulatory arrest - Appendix A. Conference discussion
    Dion, R.
    Dr Touati
    Kucuker, S.
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2007, 32 (02) : 267 - 268
  • [3] EndoClamp Aortic Catheter in the descending aorta for normothermic aortic arch replacement on the beating heart without circulatory arrest
    Di Natale, M.
    Tancredi, F.
    Bachicchio, V.
    Paternoster, G.
    Lentini, S.
    PERFUSION-UK, 2013, 28 (05): : 453 - 456
  • [4] Aortic Arch Replacement without Deep Hypothermic Circulatory Arrest
    Bakhutashvili, Zviad
    Janelidze, Lia
    Beria, Kakhaber
    Matikashvili, Simon
    Limonjiani, Eduard
    CASE REPORTS IN SURGERY, 2021, 2021
  • [5] Normothermic total arch replacement without hypothermic circulatory arrest to treat aortic distal arch aneurysm in a patient with cold agglutinin disease
    Ishida, Narihiro
    Takemura, Hirofumi
    Shimabukuro, Katsuya
    Matsuno, Yukihiro
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2011, 13 (04) : 432 - 434
  • [6] Partial aortic arch replacement without circulatory arrest: A case study
    Panfilov, Dmitri
    Kozlov, Boris
    PERFUSION-UK, 2023, 38 (04): : 681 - 683
  • [7] Hypothermic Circulatory Arrest for Aortic Arch Replacement
    Schaefers, H. -J.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2014, 28 (04): : 275 - 276
  • [8] Aortic arch replacement without circulatory arrest: A simplified technique with two grafts
    Goksel, O. S.
    Sayin, O.
    Ugurlucan, M.
    Sungur, Z.
    Tireli, E.
    Dayioglu, E.
    THORACIC AND CARDIOVASCULAR SURGEON, 2007, 55 (05): : 327 - 329
  • [9] Aortic Arch-Clamping Technique in Hemiarch Replacement Without Circulatory Arrest
    Jia, Bo
    Luo, Cheng
    Li, Chengnan
    Ge, Yipeng
    Zhong, Yongliang
    Qiao, Zhiyu
    Hu, Haiou
    Yang, Yi
    Yu, Hai
    Zhu, Junming
    HEART LUNG AND CIRCULATION, 2023, 32 (08): : e47 - e50
  • [10] Aortic arch reconstruction without circulatory arrest
    Caldarone, CA
    Behrendt, DM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (05): : 978 - 979