Test-retest reliability of an instrumented electronic walkway system (GAITRite) for the measurement of spatio-temporal gait parameters in young patients with Friedreich's ataxia

被引:17
|
作者
Roche, Bastien [1 ]
Simon, Anne-Laure [1 ,2 ]
Guilmin-Crepon, Sophie [3 ,4 ,5 ]
Boizeau, Priscilla [3 ]
Andriss, Beatrice [3 ]
Alberti, Corinne [3 ,4 ,5 ]
Presedo, Ana [2 ]
Ilharreborde, Brice [2 ]
Husson, Isabelle [6 ,7 ]
机构
[1] Robert Debre Univ Hosp, Gait & Mot Anal Lab, AP HP, Paris, France
[2] Robert Debre Univ Hosp, Pediat Orthopaed Surg Dept, AP HP, Paris, France
[3] Robert Debre Univ Hosp, Clin Epidemiol Dept, AP HP, Paris, France
[4] Robert Debre Univ Hosp, INSERM, UMR S 1123, ECEVE, Paris, France
[5] Robert Debre Univ Hosp, CIC EC 1426, Paris, France
[6] Robert Debre Univ Hosp, Phys Rehabil Dept, AP HP, Paris, France
[7] Robert Debre Univ Hosp, INSERM, UMR S 1141, Paris, France
关键词
Cerebellar ataxia; Gait analysis; Spatio-temporal parameters; GAITRite; Gait Variability Index; DISEASE SEVERITY; QUANTIFICATION; INDIVIDUALS; VALIDITY; CHILDREN; BALANCE; ADULTS;
D O I
10.1016/j.gaitpost.2018.08.017
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Friedreich ataxia (FRDA) affects the spatio-temporal parameters (STP)of gait. To our knowledge, proper tools to measure the variability of ataxic gait have not been validated yet. The aims of the present study were: (1) to measure the reproducibility of STP and gait scores in young patients with FRDA and (2) to describe the characteristics of gait parameters in this population. Methods: Thirty-six patients (18 males, 18 females) with diagnosis of FRDA (mean age 16.4 +/- 4.5 years) were asked to walk barefoot at a self-selected pace along the pressure sensitive walkway (GAITRite (R)). Three trials were recorded for each patient and repeated 48 h later. Collected data was put into statistical analysis tests to determine reliability and variability of STPs and two other gait scores: The Functional Ambulation Performance score (FAP) and the Gait Variability Index (GVI). Results: All STPs showed strong or very strong reliability (ICC > 0.7) and a low variability. The two parameters showing the lowest reliability (0.71 and 0.74) were the base of support and the foot progression angle. The FAP score and the GVI showed strong reliability (ICC > 0.8). Conclusions: The GAITRite system allows feasible and reliable measurements of gait parameters in young patients with FRDA. Lower reliability found for the weakest parameters was attributed to the software automatic errors and the ankle laxity noted in every patient.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 10 条
  • [1] Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite®)
    van Ulden, CJT
    Besser, MP
    BMC MUSCULOSKELETAL DISORDERS, 2004, 5
  • [2] Test-retest reliability of temporal and spatial gait characteristics measured with an instrumented walkway system (GAITRite)
    Van Uden C.J.T.
    Besser M.P.
    BMC Musculoskeletal Disorders, 5 (1)
  • [3] Test-retest reliability of the GAITRite walkway system for the spatio-temporal gait parameters while dual-tasking in post-stroke patients
    Cho, Ki Hun
    Lee, Hwang Jae
    Lee, Wan Hee
    DISABILITY AND REHABILITATION, 2015, 37 (06) : 512 - 516
  • [4] Test-retest reliability of spatial and temporal gait parameters in children with cerebral palsy as measured by an electronic walkway
    Sorsdahl, Anne Brit
    Moe-Nilssen, Rolf
    Strand, Liv Inger
    GAIT & POSTURE, 2008, 27 (01) : 43 - 50
  • [5] Towards Mobile Gait Analysis: Concurrent Validity and Test-Retest Reliability of an Inertial Measurement System for the Assessment of Spatio-Temporal Gait Parameters
    Kluge, Felix
    Gassner, Heiko
    Hannink, Julius
    Pasluosta, Cristian
    Klucken, Jochen
    Eskofier, Bjoern M.
    SENSORS, 2017, 17 (07):
  • [6] Concurrent Validity and Test-retest Reliability of the OPTOGait Photoelectric Cell System for the Assessment of Spatio-temporal Parameters of the Gait of Young Adults
    Lee, Myung Mo
    Song, Chang Ho
    Lee, Kyoung Jin
    Jung, Sang Woo
    Shin, Doo Chul
    Shin, Seung Ho
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2014, 26 (01) : 81 - 85
  • [7] Test-retest reliability of spatial and temporal gait parameters of people with Alzheimer's disease
    Wittwer, Joanne E.
    Webster, Kate E.
    Andrews, Peta T.
    Menz, Hylton B.
    GAIT & POSTURE, 2008, 28 (03) : 392 - 396
  • [8] Construct validity and test -retest reliability of a free mobile application for spatio-temporal gait analysis in Parkinson ?s disease patients
    Clavijo-Buendia, Sergio
    Molina-Rueda, Francisco
    Martin-Casas, Patricia
    Ortega-Bastidas, Paulina
    Monge-Pereira, Esther
    Laguarta-Val, Sofia
    Morales-Cabezas, Matilde
    Cano-de-la-Cuerda, Roberto
    GAIT & POSTURE, 2020, 79 : 86 - 91
  • [9] Agreement between the spatio-temporal gait parameters from treadmill-based photoelectric cell and the instrumented treadmill system in healthy young adults and stroke patients
    Lee, Myungmo
    Song, Changho
    Lee, Kyoungjin
    Shin, Doochul
    Shin, Seungho
    MEDICAL SCIENCE MONITOR, 2014, 20
  • [10] The OptoGait Motion Analysis System for Clinical Assessment of 2D Spatio-Temporal Gait Parameters in Young Adults: A Reliability and Repeatability Observational Study
    Carbajales-Lopez, Julia
    Becerro-de-Bengoa-Vallejo, Ricardo
    Elena Losa-Iglesias, Marta
    Casado-Hernandez, Israel
    Benito-De Pedro, Maria
    Rodriguez-Sanz, David
    Calvo-Lobo, Cesar
    San Antolin, Marta
    APPLIED SCIENCES-BASEL, 2020, 10 (11):