An evaluation of field total petroleum hydrocarbon (TPH) systems

被引:19
|
作者
Lambert, P [1 ]
Fingas, M
Goldthorp, M
机构
[1] Environm Canada, Emergencies Sci Div, Ottawa, ON K1A 0H3, Canada
[2] Goldthorp Consulting, Kemptville, ON K1A 0H3, Canada
关键词
petroleum hydrocarbons; soil; water; portable instrument; field monitoring;
D O I
10.1016/S0304-3894(00)00328-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An evaluation of several field kits and petroleum hydrocarbon measuring systems was conducted. The field kits were the immunoassay based EnviroGard petroleum fuels in soil test kit (EnviroGard, Millipore Canada, Mississauga, Ont., Canada), the turbidimetric based PetroFlag hydrocarbon test kit for soil (Dexsil, Hamden, CT, USA), a DR/2000 field kit (Hach Company, Loveland CO, USA) employing colorimetric test procedures and a total organic carbon (TOC) analysis instrument (Dohrmann Division, Rosemount Analytical Inc., Santa Clara, CA, USA) using oxidation principles. These procedures were compared to the traditional technique of extraction of the petroleum hydrocarbons using trichlorotrifluoroethane (Freon 113) as the solvent and subsequent infrared (IR) analysis using a portable fixed wavelength analyzer (Buck Scientific, East Norwalk, CT, USA). The EnviroGard kit was affected by the sample matrix. The soil type and the presence or lack thereof specific chemical components affected the capability to detect the petroleum hydrocarbon concentration. The PetroFlag soil test kit tended to generate results higher than the accepted concentration. The IR method was better capable of producing results similar to the expected concentration values of the prepared samples. Results indicate that the total organic carbon analysis technique evaluated is best suited for samples containing dissolved hydrocarbons in water and is not a preferred procedure for water samples containing dispersed or floating oil. At low concentrations of 10 ppm and less, the TOC method and IR method have concentration values within a few parts-per-million (ppm) of each other, however, an examination of the trends in the results for all samples shows no similarity. This would indicate that the traditional extraction and infrared method and the total organic carbon method are not measuring the same parameter. Finally, the colorimetric field kit was capable of quantifying the concentration of oil in water samples within limits. The results from the oil-in-water method built into the unit at the factory were not comparable with analysis carried out by the infrared technique. With specific methods for each oil incorporated into the spectrophotometer, the comparability of data increased significantly. Results generated by the kit are dependent upon the color and amount of the oil in the sample. The kit is best suited for dark colored oils and the water samples with concentrations in the range of 10 to 85 ppm by weight. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:65 / 81
页数:17
相关论文
共 50 条
  • [1] FIELD-EVALUATION OF THE SFE-INFRARED METHOD FOR TOTAL PETROLEUM HYDROCARBON (TPH) DETERMINATIONS
    HAWTHORNE, SB
    MILLER, DJ
    HEGVIK, KM
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1993, 31 (01) : 26 - 30
  • [2] A critical review of field total petroleum hydrocarbon (TPH) analysis, Part II
    Lambert, P
    Fingas, M
    PROCEEDINGS OF THE TWENTIETH ARCTIC AND MARINE OILSPILL PROGRAM (AMOP) TECHNICAL SEMINAR, VOLS 1 AND 2, 1997, : 175 - 186
  • [3] A critical review of total petroleum hydrocarbon (TPH) analysis
    Lambert, P
    Goldthorp, M
    Fieldhouse, B
    Fingas, M
    PROCEEDINGS OF THE THIRTEENTH TECHNICAL SEMINAR ON CHEMICAL SPILLS, 1996, : 167 - 181
  • [4] Evaluation of ethyl lactate as solvent in Fenton oxidation for the remediation of total petroleum hydrocarbon (TPH)-contaminated soil
    Seyedeh Pegah Jalilian Ahmadkalaei
    Suyin Gan
    Hoon Kiat Ng
    Suhaimi Abdul Talib
    Environmental Science and Pollution Research, 2017, 24 : 17779 - 17789
  • [5] Evaluation of ethyl lactate as solvent in Fenton oxidation for the remediation of total petroleum hydrocarbon (TPH)-contaminated soil
    Ahmadkalaei, Seyedeh Pegah Jalilian
    Gan, Suyin
    Ng, Hoon Kiat
    Talib, Suhaimi Abdul
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (21) : 17779 - 17789
  • [6] Beyond TPH: Health-based evaluation of petroleum hydrocarbon exposures
    Hutcheson, MS
    Pedersen, D
    Anastas, ND
    Fitzgerald, J
    Silverman, D
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 1996, 24 (01) : 85 - 101
  • [7] Determination of Total Petroleum Hydrocarbon (TPH) and Polycyclic Aromatic Hydrocarbon (PAH) in Soils: A Review of Spectroscopic and Nonspectroscopic Techniques
    Okparanma, Reuben Nwomandah
    Mouazen, Abdul Mounem
    APPLIED SPECTROSCOPY REVIEWS, 2013, 48 (06) : 458 - 486
  • [8] Evaluation of total petroleum hydrocarbon analysis specificity
    Gratson, David
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [9] A novel method to determine total petroleum hydrocarbon (TPH) and water contents in reservoir drill cuttings
    Petri Junior, Irineu
    dos Santos, Jessika M.
    Ataide, Carlos H.
    Duarte, Claudio R.
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2020, 195
  • [10] Phytodegradation of total petroleum hydrocarbon (TPH) in diesel-contaminated water using Scirpus grossus
    Al-Baldawi, Israa Abdulwahab
    Abdullah, Siti Rozaimah Sheikh
    Anuar, Nurina
    Suja, Fatihah
    Mushrifah, Idris
    ECOLOGICAL ENGINEERING, 2015, 74 : 463 - 473