Feasibility of Specific Ventilation Imaging on a 3T MRI scanner

被引:0
|
作者
O'Sullivan, C. [1 ]
Prisk, G. K. [2 ]
Nilsen, K. [3 ]
Mcintyre, R. [4 ]
Pontre, B. [5 ]
Dubowitz, D. [5 ]
Thompson, B. [6 ]
机构
[1] Newcastle Univ, Newcastle, NSW, Australia
[2] Univ Calif San Diego, Dept Med, San Diego, CA USA
[3] Swinburne Univ Technol, Melbourne, Vic, Australia
[4] Monash Univ, Monash Biomed Imaging, Melbourne, Vic, Australia
[5] Ctr Adv MRI, Auckland, New Zealand
[6] Univ Melbourne, Dept Hlth Sci, Melbourne, Vic, Australia
关键词
Measurement properties; Monitoring;
D O I
10.1183/13993003.congress-2022.400
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
400
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Sodium MRI of human articular cartilage of the wrist: a feasibility study on a clinical 3T MRI scanner
    Mueller-Lutz, Anja
    Kamp, Benedikt
    Nagel, Armin M.
    Ljimani, Alexandra
    Abrar, Daniel
    Schleich, Christoph
    Wollschlaeger, Lena
    Nebelung, Sven
    Wittsack, Hans-Joerg
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (02) : 241 - 248
  • [2] Sodium MRI of human articular cartilage of the wrist: a feasibility study on a clinical 3T MRI scanner
    Anja Müller-Lutz
    Benedikt Kamp
    Armin M. Nagel
    Alexandra Ljimani
    Daniel Abrar
    Christoph Schleich
    Lena Wollschläger
    Sven Nebelung
    Hans-Jörg Wittsack
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 241 - 248
  • [3] Calorimetric Calibration of Specific Absorption Rate (SAR) On a Compact 3T MRI Scanner
    Shu, Y.
    Tao, S.
    Yeo, D.
    Foo, T.
    Weavers, P.
    Trzasko, J.
    Huston, J.
    Bernstein, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3048 - 3048
  • [4] Reduced Field of View APT Imaging of Rectum (RAPTOR) at 3T MRI Scanner *
    Chai, Xu-Bin
    Wang, Yi
    He, Zi-Jun
    Liu, Ai-Hua
    Xue, Rong
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2024, 51 (06) : 1471 - 1478
  • [5] 3T MRI: necessary for musculoskeletal imaging
    Cotten, A.
    JOURNAL DE RADIOLOGIE, 2009, 90 (05): : 543 - 543
  • [6] Evaluation of the MRI compatibility of PET detectors modules for organ-specific inserts in a 3T and 7T MRI scanner
    Schmidt, Fabian P.
    Allen, Magdelena S.
    Ladebeck, Ralf
    Breuer, Johannes
    Judenhofer, Martin
    Schmand, Matthias
    Catana, Ciprian
    Pichler, Bernd J.
    MEDICAL PHYSICS, 2024, 51 (02) : 991 - 1006
  • [7] Conformance of a 3T radiotherapy MRI scanner to the QIBA Diffusion Profile
    Carr, Madeline E.
    Keenan, Kathryn E.
    Rai, Robba
    Boss, Michael A.
    Metcalfe, Peter
    Walker, Amy
    Holloway, Lois
    MEDICAL PHYSICS, 2022, 49 (07) : 4508 - 4517
  • [8] Multi-Echo-Based Echo-Planar Spectroscopic Imaging Using a 3T MRI Scanner
    Furuyama, Jon K.
    Burns, Brian L.
    Wilson, Neil E.
    Thomas, M. Albert
    MATERIALS, 2011, 4 (10): : 1818 - 1834
  • [9] Ag/AgCl electrodes in the EEG/fMRI method in 3T MRI scanner
    Akay, Cengiz
    Kepceoglu, Abdullah
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2013, 64 (01):
  • [10] Extracellular pH mapping of liver cancer on a clinical 3T MRI scanner
    Coman, Daniel
    Peters, Dana C.
    Walsh, John J.
    Savic, Lynn J.
    Huber, Steffen
    Sinusas, Albert J.
    Lin, MingDe
    Chapiro, Julius
    Constable, R. Todd
    Rothman, Douglas L.
    Duncan, James S.
    Hyder, Fahmeed
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1553 - 1564