A Modified Sequence-Domain Impedance Definition and Its Equivalence to the dq-Domain Impedance Definition for the Stability Analysis of AC Power Electronic Systems

被引:459
作者
Rygg, Atle [1 ]
Molinas, Marta [1 ]
Zhang, Chen [2 ]
Cai, Xu [2 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Engn Cybernet, N-7491 Trondheim, Norway
[2] Shanghai Jiao Tong Univ, State Energy Smart Grid R&D Ctr, Shanghai 200240, Peoples R China
关键词
dq domain; impedance; power electronic systems; sequence domain; stability analysis; INVERTERS; CRITERION;
D O I
10.1109/JESTPE.2016.2588733
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Representation of ac power systems by frequency-dependent impedance equivalents is an emerging technique in the dynamic analysis of power systems including power electronic converters. The technique has been applied for decades in dc-power systems, and it was recently adopted to map the impedances in ac systems. Most of the work on ac systems can be categorized into two approaches. One is the analysis of the system in the dq domain, whereas the other applies harmonic linearization in the phase domain through symmetric components. Impedance models based on analytical calculations, numerical simulation, and experimental studies have been previously developed and verified in both domains independently. The authors of previous studies discuss the advantages and disadvantages of each domain separately, but neither a rigorous comparison nor an attempt to bridge them has been conducted. This paper attempts to close this gap by deriving the mathematical formulation that shows the equivalence between the dq-domain and the sequence-domain impedances. A modified form of the sequence-domain impedance matrix is proposed, and with this definition the stability estimates obtained with the generalized Nyquist criterion become equivalent in both domains. The second contribution of this paper is the definition of a mirror frequency decoupled (MFD) system. The analysis of MFD systems is less complex than that of non-MFD systems because the positive and negative sequences are decoupled. This paper shows that if a system is incorrectly assumed to be MFD, this will lead to an erroneous or ambiguous estimation of the equivalent impedance.
引用
收藏
页码:1383 / 1396
页数:14
相关论文
共 27 条
[1]  
[Anonymous], 2013, P IEEE 14 WORKSH CON
[2]   Couplings in Phase Domain Impedance Modeling of Grid-Connected Converters [J].
Bakhshizadeh, Mohammad Kazem ;
Wang, Xiongfei ;
Blaabjerg, Frede ;
Hjerrild, Jesper ;
Kocewiak, Lukasz ;
Bak, Claus Leth ;
Hesselbk, Bo .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (10) :6792-6796
[3]  
Belkhayat M., 1997, STABILITY CRITERIA A
[4]  
Bing Z., 2010, THESIS
[5]   On the Ac Stability of High Power Factor Three-Phase Rectifiers [J].
Burgos, Rolando ;
Boroyevich, Dushan ;
Wang, Fred ;
Karimi, Kamiar ;
Francis, Gerald .
2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, :2047-2054
[6]   Adaptive Control of Grid-Connected Inverters Based on Online Grid Impedance Measurements [J].
Cespedes, Mauricio ;
Sun, Jian .
IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2014, 5 (02) :516-523
[7]   Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters [J].
Cespedes, Mauricio ;
Sun, Jian .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1254-1261
[8]   ON THE GENERALIZED NYQUIST STABILITY-CRITERION [J].
DESOER, CA ;
WANG, YT .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1980, 25 (02) :187-196
[9]   Analysis of Phase-Locked Loop Low-Frequency Stability in Three-Phase Grid-Connected Power Converters Considering Impedance Interactions [J].
Dong, Dong ;
Wen, Bo ;
Boroyevich, Dushan ;
Mattavelli, Paolo ;
Xue, Yaosuo .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (01) :310-321
[10]   New Techniques for Measuring Impedance Characteristics of Three-Phase AC Power Systems [J].
Familiant, Yakov A. ;
Huang, Jing ;
Corzine, Keith A. ;
Belkhayat, Mohamed .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (07) :1802-1810