Evaluation of a stochastic approach to 2D-3D intensity-based registration

被引:0
|
作者
Aouadi, S. [1 ]
Sarry, L. [1 ]
机构
[1] INSERM, ERIM ERI 14, F-63001 Clermont Ferrand, France
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
this paper assesses a new 2D-3D rigid registration method based on stochastic clustering and an enhanced estimator for mutual information. It combines precision, accuracy and acceptable computation time. Spine datasets (fluoroscopy and computed tomography) with their gold standard transformations are used. Both optimization method and similarity measure are assessed separately using standardized evaluation methodologies. Sub-millimeter accuracy and the high convergence rate obtained within one minute are compared to other quasi-global optimization processes such as particle filtering.
引用
收藏
页码:6388 / 6391
页数:4
相关论文
共 50 条
  • [1] Multilevel 2D-3D Intensity-Based Image Registration
    Lange, Annkristin
    Heldmann, Stefan
    BIOMEDICAL IMAGE REGISTRATION (WBIR 2020), 2020, 12120 : 57 - 66
  • [2] Intensity-based 2D-3D registration for an ACL reconstruction navigation system
    Guo, Na
    Yang, Biao
    Ji, Xuquan
    Wang, Yuhan
    Hu, Lei
    Wang, Tianmiao
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2019, 15 (04):
  • [3] Markov Random Field Optimization for Intensity-based 2D-3D Registration
    Zikic, Darko
    Glocker, Ben
    Kutter, Oliver
    Groher, Martin
    Komodakis, Nikos
    Khamene, Ali
    Paragios, Nikos
    Navab, Nassir
    MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [4] MAP-MRF based similarity measures for intensity-based 2D-3D registration
    Zheng, G.
    Zhang, X.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 50 - 53
  • [5] Evaluation of optimization methods for intensity-based 2D-3D registration in x-ray guided interventions
    van der Bom, I. M. J.
    Klein, S.
    Staring, M.
    Homan, R.
    Bartels, L. W.
    Pluim, J. P. W.
    MEDICAL IMAGING 2011: IMAGE PROCESSING, 2011, 7962
  • [6] Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy
    Wu, Jian
    Kim, Minho
    Peters, Jorg
    Chung, Heeteak
    Samant, Sanjiv S.
    MEDICAL PHYSICS, 2009, 36 (12) : 5391 - 5403
  • [7] Intensity-based 2D-3D spine image registration incorporating one fiducial marker
    Russakoff, DB
    Rohlfing, T
    Shahidi, R
    Kim, DH
    Adler, JR
    Maurer, CR
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2003, PT 1, 2003, 2878 : 287 - 294
  • [8] Intensity-based 2D-3D spine image registration incorporating a single fiducial marker
    Russakoff, DB
    Rohlfing, T
    Adler, JR
    Maurer, CR
    ACADEMIC RADIOLOGY, 2005, 12 (01) : 37 - 50
  • [9] Evaluation of intensity-based 2D-3D spine image registration using clinical gold-standard data
    Russakoff', DB
    Rohlfing, T
    Ho, A
    Kim, DH
    Shahidi, R
    Adler, JR
    Maurer, CR
    BIOMEDICAL IMAGE REGISTRATION, 2003, 2717 : 151 - 160
  • [10] Fast intensity-based 2D-3D image registration of clinical data using light fields
    Russakoff, DB
    Rohlfing, T
    Maurer, CR
    NINTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS I AND II, PROCEEDINGS, 2003, : 416 - 422