The improved dual-view field goniometer system FIGOS

被引:31
|
作者
Schopfer, Juerg [1 ]
Dangel, Stefan [1 ]
Kneubuehler, Mathias [1 ]
Itten, Klaus I. [1 ]
机构
[1] Univ Zurich, Remote Sensing Labs, CH-8057 Zurich, Switzerland
关键词
dual-view field goniometer system FIGOS; BRF retrieval; BRDF; atmospheric influence; diffuse illumination; spectrodirectional Remote Sensing;
D O I
10.3390/s8085120
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In spectrodirectional Remote Sensing (RS) the Earth's surface reflectance characteristics are studied by means of their angular dimensions. Almost all natural surfaces exhibit an individual anisotropic reflectance behaviour due to the contrast between the optical properties of surface elements and background and the geometric surface properties of the observed scene. The underlying concept, which describes the reflectance characteristic of a specific surface area, is called the bidirectional reflectance distribution function (BRDF). BRDF knowledge is essential for both correction of directional effects in RS data and quantitative retrieval of surface parameters. Ground-based spectrodirectional measurements are usually performed with goniometer systems. An accurate retrieval of the bidirectional reflectance factors (BRF) from field goniometer measurements requires hyperspectral knowledge of the angular distribution of the reflected and the incident radiation. However, prior to the study at hand, no operational goniometer system was able to fulfill this requirement. This study presents the first dual-view field goniometer system, which is able to simultaneously collect both the reflected and the incident radiation at high angular and spectral resolution and, thus, providing the necessary spectrodirectional datasets to accurately retrieve the surface specific BRF. Furthermore, the angular distribution of the incoming diffuse radiation is characterized for various atmospheric conditions and the BRF retrieval is performed for an artificial target and compared to laboratory spectrodirectional measurement results obtained with the same goniometer system. Suggestions for further improving goniometer systems are given and the need for intercalibration of various goniometers as well as for standardizing spectrodirectional measurements is expressed.
引用
收藏
页码:5120 / 5140
页数:21
相关论文
共 50 条
  • [1] Combined field and laboratory goniometer system -: FIGOS and LAGOS
    Dangel, S
    Kneubühler, M
    Schaepman, M
    Schopfer, J
    Schaepman-Strub, G
    Itten, K
    IGARSS 2003: IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS I - VII, PROCEEDINGS: LEARNING FROM EARTH'S SHAPES AND SIZES, 2003, : 4428 - 4430
  • [2] A field goniometer system (FIGOS) for acquisition of hyperspectral BRDF data
    Sandmeier, SR
    Itten, KI
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 1999, 37 (02): : 978 - 986
  • [3] Field goniometer system (FIGOS) for acquisition of hyperspectral BRDF data
    Univ of Zurich, Zurich, Switzerland
    IEEE Trans Geosci Remote Sens, 2 II (978-986):
  • [4] Acquisition of bidirectional reflectance data using the Swiss field-goniometer system (FIGOS)
    Sandmeier, S
    Itten, KI
    Schaepman, ME
    Kellenberger, TW
    Sandmeier, W
    PROGRESS IN ENVIRONMENTAL REMOTE SENSING RESEARCH AND APPLICATIONS, 1996, : 55 - 61
  • [5] Development of a dual-view endoscope system
    Sekiya, Takaomi
    Ito, Eiichi
    Kanai, Moriyasu
    Matsumoto, Mitsuhiro
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS IV, 2006, 6080
  • [6] Potential for improved ATSR dual-view SST retrieval
    Murray, MJ
    Allen, MR
    Merchant, CJ
    Harris, AR
    GEOPHYSICAL RESEARCH LETTERS, 1998, 25 (17) : 3363 - 3366
  • [7] Potential for improved ATSR dual-view SST retrieval
    Space Science Department, Rutherford Appleton Laboratory, Chilton, United Kingdom
    不详
    不详
    不详
    不详
    不详
    不详
    Geophys. Res. Lett., 17 (3363-3366):
  • [8] Quality Assessment for Dual-View Display System
    Chen, Yuanchun
    Liu, Ning
    Zhai, Guangtao
    Gu, Ke
    Wang, Jia
    Gao, Zhongpai
    Zhu, Yucheng
    2016 30TH ANNIVERSARY OF VISUAL COMMUNICATION AND IMAGE PROCESSING (VCIP), 2016,
  • [9] Compact dual-view endoscope without field obscuration
    Katkam, Rajender
    Banerjee, Bhaskar
    Huang, Chih Yu
    Zhu, Xiaoyin
    Ocampo, Luis
    Kincade, Jerri-Lynn
    Liang, Rongguang
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (07)
  • [10] An Improved Algorithm for Real-Time Dual-View Display
    Sun, Wenjie
    Gao, Zhongpai
    Zhai, Guangtao
    Zhang, Jiahe
    Wang, Zhaodi
    Zhu, Yucheng
    2020 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2020,