Effectiveness of an air cleaner device in reducing aerosol numbers and airborne bacteria from an enclosed type dairy barn

被引:5
|
作者
Islam, Md Aminul [1 ,2 ]
Ikeguchi, Atsuo [3 ]
Naide, Takanori [4 ]
机构
[1] Tokyo Univ Agr & Technol, United Grad Sch Agr Sci, Dept Agr & Environm Engn, 3-5-8 Saiwai Cho, Fuchu, Tokyo 1838509, Japan
[2] Bangabandhu Sheikh Mujibur Rahman Agr Univ, Fac Vet Med & Anim Sci, Dept Med, Gazipur 1706, Bangladesh
[3] Utsunomiya Univ, Fac Agr, Dept Environm Engn, 350 Minemachi, Utsunomiya, Tochigi 3218505, Japan
[4] Earth Environm Serv Co Ltd, Chiyoda Ku, 17 Kanda Konyacho, Tokyo 1010035, Japan
关键词
Aerosol numbers; Air cleaning; Airborne bacteria; Dairy barn; Filtration; Photocatalysis; LIVESTOCK BUILDINGS; PARTICULATE MATTER; DUST; PHOTOCATALYSIS; EMISSIONS; REMOVAL; VIRUS; TIO2; INACTIVATION; IONIZATION;
D O I
10.1007/s11356-022-19514-2
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
There is growing pressure to find technically feasible and economically viable solutions in reducing emissions of pollutants from various occupational settings to minimise environmental pollution. Hence, it is essential to develop and test methods for controlling pollutants from occupational backgrounds. We have tested an air cleaner device in reducing aerosol numbers by filtration and airborne bacteria by photocatalysis from an enclosed type dairy barn. Here, we had shown a significant reduction of larger size aerosol numbers (2.0-10.0 mu m) and airborne total aerobic bacteria and Staphylococcus aureus (S. aureus) and complete clearance of Escherichia coli (E. coli) in the exhaust air of the air cleaner device. A greater 8.05% and 61.56% reduction of 5.0-10.0 mu m aerosol numbers and airborne E. coli, respectively, were observed in the instantly treated central air of the dairy barn. We had found an increasing trend of aerosol numbers and airborne bacteria concentrations in the central air of the dairy barn after stopping the air cleaner device. We also had observed increased bacterial load in the filter paper of the air treatment chamber of the air cleaner device with the advancement of cleaning time. These findings are essential to validate air cleanings from various types of dairy microenvironments.
引用
收藏
页码:53022 / 53035
页数:14
相关论文
共 8 条
  • [1] Effectiveness of an air cleaner device in reducing aerosol numbers and airborne bacteria from an enclosed type dairy barn
    Md. Aminul Islam
    Atsuo Ikeguchi
    Takanori Naide
    Environmental Science and Pollution Research, 2022, 29 : 53022 - 53035
  • [2] Relationships Among Aerosol Particles, Airborne Bacteria, and Microclimatic Factors in an Enclosed Dairy Milking Barn
    Islam, Md. Aminul
    Ikeguchi, Atsuo
    Naide, Takanori
    AEROSOL SCIENCE AND ENGINEERING, 2025,
  • [3] Concentrations of Aerosol Numbers and Airborne Bacteria, and Temperature and Relative Humidity, and Their Interrelationships in a Tie-Stall Dairy Barn
    Islam, Md. Aminul
    Ikeguchi, Atsuo
    Naide, Takanori
    ANIMALS, 2019, 9 (12):
  • [4] Effectiveness of a portable personal air cleaner in reducing the airborne transmission of respiratory pathogens
    Cortellessa, Gino
    Canale, Christian
    Stabile, Luca
    Grossi, Giorgio
    Buonanno, Giorgio
    Arpino, Fausto
    BUILDING AND ENVIRONMENT, 2023, 235
  • [5] Influence of temperature and humidity on the dynamics of aerosol numbers and airborne bacteria in a dairy calf house
    Islam M.A.
    Ikeguchi A.
    Naide T.
    Biosystems Engineering, 2020, 194 : 213 - 226
  • [6] Efficiency of an Air Cleaner Device in Reducing Aerosol Particulate Matter (PM) in Indoor Environments
    Fermo, Paola
    Comite, Valeria
    Falciola, Luigi
    Guglielmi, Vittoria
    Miani, Alessandro
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (01)
  • [7] The effectiveness of an air cleaner in controlling droplet/aerosol particle dispersion emitted from a patient's mouth in the indoor environment of dental clinics
    Chen, Chun
    Zhao, Bin
    Cui, Weilin
    Dong, Lei
    An, Na
    Ouyang, Xiangying
    JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2010, 7 (48) : 1105 - 1118
  • [8] A comparison of the effectiveness of a temperature controlled laminar airflow device and a room air-cleaner in reducing particle concentrations in the breathing zone of a thermal manikin lying in a bed
    Sigsgaard, T.
    Ravn, P.
    Svensson, P.
    Takai, H.
    ALLERGY, 2010, 65 : 735 - 735