Investigation of lightning surge current induced in reinforced concrete buildings by direct strikes

被引:0
|
作者
Kato, J [1 ]
Kawano, H [1 ]
Tominaga, T [1 ]
Kuramoto, S [1 ]
机构
[1] Nippon Telegraph & Tel Corp, Lifestyle & Environm Technol Lab, Musashino, Tokyo, Japan
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Direct lightning strikes to reinforced concrete buildings cause telecommunication equipment to malfunction. The lightning surge currents induced in the building should be investigated to develop the countermeasure method against these strikes. A telecommunication building was modeled by a wire-frame model which presents the beams and pillars of a building. The element of each wire-frame was calculated based on the electromagnetic theory. The induced lightning surge was calculated from the observed waveform of lightning current by using SPICE and FFT. The calculated waveforms at the pillars were compared with observed values. The result showed that a similar waveform could be obtained by the calculation. The calculated deviation of the peak values at pillars were almost agree with the observed value. The results indicate that the model can be used to estimate the tendencies of the lightning surge distribution in reinforced concrete buildings. The lightning surge distribution was calculated by this model. The results showed that the range of value among pillars decreased for the lower floors.
引用
收藏
页码:1009 / 1014
页数:6
相关论文
共 50 条
  • [1] Surge current distribution in a reinforced concrete structure during building struck by lightning
    Tsinghua Univ, Beijing, China
    Qinghua Daxue Xuebao, 5 (28-30, 34):
  • [2] Experimental direct lightning current distribution in a reinforced concrete building
    Sato, Masaji
    Kuramoto, Shoichi
    Electronics and Communications in Japan, Part I: Communications (English translation of Denshi Tsushin Gakkai Ronbunshi), 2000, 83 (04): : 53 - 62
  • [3] Experimental direct lightning current distribution in a reinforced concrete building
    Sato, M
    Kuramoto, S
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART I-COMMUNICATIONS, 2000, 83 (04): : 53 - 62
  • [4] Evaluation of Lightning Induced Magnetic Fields Inside Reinforced Concrete Buildings
    Miry, C.
    Amador, E.
    Duquerroy, P.
    Bachelier, E.
    Prost, D.
    Issac, F.
    2013 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XII SIPDA), 2013, : 145 - 150
  • [5] Experimental and numerical evaluation of surge current distribution in buildings during a direct lightning stroke
    Du, Y.
    Burnett, John
    Chen, Shuiming
    HKIE Transactions Hong Kong Institution of Engineers, 2001, 8 (01): : 1 - 6
  • [6] Protection against lightning of reinforced concrete buildings
    Bachelier, E.
    Issac, F.
    Prost, D.
    Miry, C.
    Amador, E.
    Duquerroy, P.
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 735 - 740
  • [7] Experimental investigation of the repeatability of direct damage induced by lightning strikes on metallic panels
    Alhossen, I.
    Espinosa, C.
    Chieragatti, R.
    Hor, A.
    Pierre, E.
    Vilcocq, S.
    Montel, T.
    Gnangnon, O.
    15TH HIGH-TECH PLASMA PROCESSES CONFERENCE (HTPP15), 2019, 1243
  • [8] Calculation of Current Distribution during direct strikes to Lightning Protective System
    Wang, Ping
    Li, Lin
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1087 - 1090
  • [9] The impact of multiple lightning strokes on the energy absorbed by MOV surge arresters in wind farms during direct lightning strikes
    Malcolm, Newman
    Aggarwal, Raj K.
    RENEWABLE ENERGY, 2015, 83 : 1305 - 1314
  • [10] Investigation of the effects of recycled aggregate concrete on the performance of reinforced concrete buildings
    Alemdar, Zeynep Firat
    Kurt, Yavuz Selim
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2022, 37 (02): : 1077 - 1090