Biomechanics in Removable Partial Dentures: A Literature Review of FEA-Based Studies

被引:17
|
作者
Mousa, Mohammed A. [1 ,2 ]
Abdullah, Johari Yap [3 ]
Jamayet, Nafij B. [4 ]
El-Anwar, Mohamed I. [5 ]
Ganji, Kiran Kumar [6 ]
Alam, Mohammad Khursheed [6 ]
Husein, Adam [1 ]
机构
[1] Univ Sains Malaysia, Sch Dent Sci, Prosthodont Unit, Kubang Kerian 16150, Kelantan, Malaysia
[2] Jouf Univ, Dept Prosthet Dent Sci, Coll Dent, Sakakah, Jouf, Saudi Arabia
[3] Univ Sains Malaysia, Sch Dent Sci, Craniofacial Imaging & Addit Mfg Lab, Kubang Kerian 16150, Kelantan, Malaysia
[4] Int Med Univ, Sch Dent, Div Restorat Dent, Jalan Jalil Perkasa 19, Kuala Lumpur 57000, Malaysia
[5] Natl Res Ctr, Mech Engn Dept, Giza, Egypt
[6] Jouf Univ, Dept Prevent Dent, Coll Dent, Sakakah, Saudi Arabia
关键词
FINITE-ELEMENT-ANALYSIS; STRESS-DISTRIBUTION; DENTAL PROSTHESES; OSSEOINTEGRATED IMPLANT; MASTICATORY EFFICIENCY; MUSCULAR-ACTIVITY; ABUTMENT TEETH; SURVIVAL RATE; CLASPS; RETENTION;
D O I
10.1155/2021/5699962
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The present study was aimed at reviewing the studies that used finite element analysis (FEA) to estimate the biomechanical stress arising in removable partial dentures (RPDs) and how to optimize it. A literature survey was conducted for the English full-text articles, which used only FEA to estimate the stress developed in RPDs from Jan 2000 to May 2021. In RPDs, the retaining and supporting structures are subjected to dynamic loads during insertion and removal of the prosthesis as well as during function. The majority of stresses in free-end saddle (FES) RPDs are concentrated in the shoulder of the clasp, the horizontal curvature of the gingival approaching clasp, and the part of the major connector next to terminal abutments. Clasps fabricated from flexible materials were beneficial to eliminate the stress in the abutment, while rigid materials were preferred for major connectors to eliminate the displacement of the prosthesis. In implant-assisted RPD, the implant receive the majority of the load, thereby reducing the stress on the abutment and reducing the displacement of the prosthesis. The amount of stress in the implant decreases with zero or minimal angulation, using long and wide implants, and when the implants are placed in the first molar area.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] TITANIUM IN REMOVABLE PARTIAL DENTURES - A REVIEW OF THE LITERATURE
    Nagarajan, Keerthiga
    Devi, Sanjana N.
    Veeraiyan, Deepak Nallaswamy
    INTERNATIONAL JOURNAL OF EARLY CHILDHOOD SPECIAL EDUCATION, 2022, 14 (05) : 2909 - 2918
  • [2] Indications for removable partial dentures:: A literature review
    Wöstmann, B
    Budtz-Jorgensen, E
    Jepson, N
    Mushimoto, E
    Palmqvist, S
    Sofou, A
    Öwall, B
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2005, 18 (02) : 139 - 145
  • [4] Implants in Conjunction With Removable Partial Dentures: A Literature Review
    Mijiritsky, Eitan
    IMPLANT DENTISTRY, 2007, 16 (02) : 146 - 154
  • [5] PERIODONTAL REACTIONS RELATED TO REMOVABLE PARTIAL DENTURES - A LITERATURE-REVIEW
    BERGMAN, B
    JOURNAL OF PROSTHETIC DENTISTRY, 1987, 58 (04): : 454 - 458
  • [6] Polyoxymethylene as Material for Removable Partial Dentures-A Literature Review and Illustrating Case Report
    Schierz, Oliver
    Schmohl, Leonie
    Hahnel, Sebastian
    Rauch, Angelika
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (07)
  • [7] Special Purpose Removable Partial Dentures - Review Article
    Niranjana, R.
    Ramesh, Ganesh
    Nayar, Sanjna
    Swamikannu, Bhuminathan
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2021, : 234 - 239
  • [8] Present status of titanium removable dentures - a review of the literature
    Ohkubo, C.
    Hanatani, S.
    Hosoi, T.
    JOURNAL OF ORAL REHABILITATION, 2008, 35 (09) : 706 - 714
  • [9] ALUMINUM-BASED TEMPORARY REMOVABLE PARTIAL DENTURES
    NELSON, DR
    VONGONTEN, AS
    WILLIAMS, CM
    JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (06): : 877 - 879
  • [10] A REVIEW OF TECHNIQUES OF CROWN FABRICATION FOR EXISTING REMOVABLE PARTIAL DENTURES
    TRAN, CD
    SHERRADEN, DR
    CURTIS, TA
    JOURNAL OF PROSTHETIC DENTISTRY, 1986, 55 (06): : 671 - 673