A time-saving method to assess the efficiency of corrosion inhibitors by electro osmosis

被引:0
|
作者
Geng, Chun-lei [1 ,2 ]
Weng, Duan [1 ]
机构
[1] Tsinghua Univ, Dept Mat Sci & Engn, Beijing 100084, Peoples R China
[2] Beijing Bldg Mat Acad Sci Res, State Key Lab, Beijing 100041, Peoples R China
关键词
reinforced concrete; corrosion; corrosion inhibitors; corrosion protection; REINFORCED-CONCRETE; FLY-ASH; STEEL; DURABILITY; PERFORMANCE; RESISTANCE; CHLORIDES;
D O I
10.1007/s12613-011-0449-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The corrosion inhibitor is one of the most important technologies to enhance the durability of steel-reinforced concrete. A kind of time-saving method was developed to assess the inhibitor efficiency by using a 32 V electric field to accelerate chloride ion migration in concrete. Potentiodynamic polarization scanning test was used to evaluate the corrosion states. The comprehensive efficiency of an inhibitor should be assessed in two aspects: resistance to chloride ion permeability and inhibiting efficiency. The specimens with different mixing amount of sodium nitrite and migration corrosion inhibitors were used to verify the accuracy and reliability of this method. The results show the differences in inhibiting efficiency of the inhibitors clearly, indicating the reliability of this time-saving method.
引用
收藏
页码:370 / 376
页数:7
相关论文
共 50 条