Effect of intravascular ligand binding on parameter estimates derived from tracer kinetic modelling

被引:3
|
作者
Buck, A
Burger, C
机构
[1] Division of Nuclear Medicine, Department of Radiology, University Hospital
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1996年 / 23卷 / 04期
关键词
positron emission tomography; tracer kinetic modelling; protein binding;
D O I
10.1007/BF01247371
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to assess the effect of intravascular ligand binding on parameter estimates derived from tracer kinetic modelling. To this end intravascular ligand kinetics between the free and a bound compartment in plasma and the exchange of tracer between the capillary space and tissue were analysed using a simple compartment model. The effect of non-equilibrated intravascular compartments on parameter estimates was evaluated in a computer simulation. It was found that three kinetic situations must be distinguished. If the intravascular compartments are fully equilibrated when the ligand reaches the target organ, intravascular binding simply acts as a scale factor for the transport-related parameter K-1. If the intravascular kinetics is very slow, only minimal binding will occur. In between there is a range where ongoing equilibration leads to time variability of K-1. Since tracer kinetic modelling usually does not account for such time variability, the parameter estimates become biased, the degree of the bias depending on the intravascular binding kinetics. Furthermore the bias may be dependent on receptor density, meaning that model-derived receptor estimates are not linearly related to the true receptor density. It is concluded that intravascular ligand binding can severely affect parameter estimates derived from tracer kinetic modelling. Especially disturbing are effects due to ongoing intravascular equilibration following the arrival of the ligand in the target organ. These can be avoided by letting the ligand equilibrate with blood in a syringe prior to injection.
引用
收藏
页码:422 / 430
页数:9
相关论文
共 50 条
  • [1] Effect of intravascular ligand binding on parameter estimates derived from tracer kinetic modelling
    Division of Nuclear Medicine, Department of Radiology, University Hospital, CH-8091 Zurich, Switzerland
    Eur. J. Nucl. Med. Mol. Imaging, 4 (422-430):
  • [2] Effect of non-constant flow on binding parameter estimation obtained with tracer kinetic modeling.
    Slifstein, M
    Narendran, R
    Endres, CJ
    Laruelle, M
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 11P - 11P
  • [3] ANALYSIS OF KINETIC AND BINDING MEASUREMENTS .2. RELIABILITY OF PARAMETER ESTIMATES
    REICH, JG
    WINKLER, J
    ZINKE, I
    STUDIA BIOPHYSICA, 1974, 42 (03): : 181 - 193
  • [4] The effect of weighting the observations on parameter estimates in groundwater modelling
    Leijnse, A.
    Pastoors, M.J.H.
    Roelofsen, F.J.
    IAHS-AISH Publication, 2002, (277): : 204 - 211
  • [5] The effect of weighting the observations on parameter estimates in groundwater modelling
    Leijnse, A
    CALIBRATION AND RELIABILITY IN GROUNDWATER MODELLING: A FEW STEPS CLOSER TO REALITY, 2003, (277): : 204 - 211
  • [6] Estimates of Glomerular Filtration Rate From MR Renography and Tracer Kinetic Models
    Bokacheva, Louisa
    Rusinek, Henry
    Zhang, Jeff L.
    Chen, Qun
    Lee, Vivian S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) : 371 - 382
  • [7] The effect of heart motion on kinetic parameter estimates for dynamic cardiac SPECT
    Ross, SG
    Gullberg, GT
    Huesman, RH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) : 1409 - 1416
  • [8] STABILITY OF PARAMETER ESTIMATES DERIVED FROM THE POWER TIME RELATIONSHIP
    SMITH, JC
    HILL, DW
    CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 1993, 18 (01): : 43 - 47
  • [9] Effect of Censoring Due to Progressive Disease on Tumor Size Kinetic Parameter Estimates
    Bonate, Peter L.
    Suttle, Ben
    AAPS JOURNAL, 2013, 15 (03): : 832 - 839
  • [10] Effect of Censoring Due to Progressive Disease on Tumor Size Kinetic Parameter Estimates
    Peter L. Bonate
    Ben Suttle
    The AAPS Journal, 2013, 15 : 832 - 839