Robust bronchoscope motion tracking using sequential Monte Carlo methods in navigated bronchoscopy: dynamic phantom and patient validation

被引:15
|
作者
Luo, Xiongbiao [1 ]
Feuerstein, Marco [2 ]
Kitasaka, Takayuki [3 ]
Mori, Kensaku [1 ]
机构
[1] Nagoya Univ, Grad Sch Informat Sci, Nagoya, Aichi 4648601, Japan
[2] Tech Univ Munich, Munich, Germany
[3] Aichi Inst Technol, Fac Informat Sci, Toyota 47003, Japan
关键词
Sequential Monte Carlo methods; Bronchoscope motion tracking; Virtual bronchoscopy; Navigated bronchoscopy; SYSTEM; SEGMENTATION; REGISTRATION; GUIDANCE; SENSOR;
D O I
10.1007/s11548-011-0645-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Accurate and robust estimates of camera position and orientation in a bronchoscope are required for navigation. Fusion of pre-interventional information (e.g., CT, MRI, or US) and intra-interventional information (e.g., bronchoscopic video) were incorporated into a navigation system to provide physicians with an augmented reality environment for bronchoscopic interventions. Two approaches were used to predict bronchoscope movements by incorporating sequential Monte Carlo (SMC) simulation including (1) image-based tracking techniques and (2) electromagnetic tracking (EMT) methods. SMC simulation was introduced to model ambiguities or uncertainties that occurred in image- and EMT-based bronchoscope tracking. Scale invariant feature transform (SIFT) features were employed to overcome the limitations of image-based motion tracking methods. Validation was performed on five phantom and ten human case datasets acquired in the supine position. For dynamic phantom validation, the EMT-SMC simulation method improved the tracking performance of the successfully registered bronchoscopic video frames by 12.7% compared with a hybrid-based method. In comparisons between tracking results and ground truth, the accuracy of the EMT-SMC simulation method was 1.51 mm (positional error) and 5.44A degrees (orientation error). During patient assessment, the SIFT-SMC simulation scheme was more stable or robust than a previous image-based approach for bronchoscope motion estimation, showing 23.6% improvement of successfully tracked frames. Comparing the estimates of our method to ground truth, the position and orientation errors are 3.72 mm and 10.2A degrees, while those of our previous image-based method were at least 7.77 mm and 19.3A degrees. The computational times of our EMT- and SIFT-SMC simulation methods were 0.9 and 1.2 s per frame, respectively. The SMC simulation method was developed to model ambiguities that occur in bronchoscope tracking. This method more stably and accurately predicts the bronchoscope camera position and orientation parameters, reducing uncertainties due to problematic bronchoscopic video frames and airway deformation during intra-bronchoscopy navigation.
引用
收藏
页码:371 / 387
页数:17
相关论文
共 31 条
  • [1] Robust bronchoscope motion tracking using sequential Monte Carlo methods in navigated bronchoscopy: dynamic phantom and patient validation
    Xióngbiāo Luó
    Marco Feuerstein
    Takayuki Kitasaka
    Kensaku Mori
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 371 - 387
  • [2] Modified Hybrid Bronchoscope Tracking Based on Sequential Monte Carlo Sampler: Dynamic Phantom Validation
    Luo, Xiongbiao
    Reichl, Tobias
    Feuerstein, Marco
    Kitasaka, Takayuki
    Mori, Kensaku
    COMPUTER VISION - ACCV 2010, PT III, 2011, 6494 : 409 - +
  • [3] Externally Navigated Bronchoscopy Using 2-D Motion Sensors: Dynamic Phantom Validation
    Luo, Xiongbiao
    Kitasaka, Takayuki
    Mori, Kensaku
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (10) : 1745 - 1764
  • [4] Bronchoscope motion tracking using centerline-guided Gaussian mixture model in navigated bronchoscopy
    Navaei Lavasani, Saeedeh
    Farnia, Parastoo
    Najafzadeh, Ebrahim
    Saghatchi, Samaneh
    Samavati, Mehdi
    Abtahi, Hamidreza
    Deevband, Mohammadreza
    Ahmadian, Alireza
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (02):
  • [5] ManiSMC: A New Method Using Manifold Modeling and Sequential Monte Carlo Sampler for Boosting Navigated Bronchoscopy
    Luo, Xiongbiao
    Kitasaka, Takayuki
    Mori, Kensaku
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT III, 2011, 6893 : 248 - +
  • [6] Structure from motion using sequential Monte Carlo methods
    Qian, G
    Chellappa, R
    INTERNATIONAL JOURNAL OF COMPUTER VISION, 2004, 59 (01) : 5 - 31
  • [7] Structure from motion using sequential Monte Carlo methods
    Qian, G
    Chellappa, R
    EIGHTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOL II, PROCEEDINGS, 2001, : 614 - 621
  • [8] Structure from Motion Using Sequential Monte Carlo Methods
    Gang Qian
    Rama Chellappa
    International Journal of Computer Vision, 2004, 59 : 5 - 31
  • [9] Online multitarget detection and tracking using sequential Monte Carlo methods
    Li, J
    Ng, W
    Godsill, S
    Vermaak, J
    2005 7TH INTERNATIONAL CONFERENCE ON INFORMATION FUSION (FUSION), VOLS 1 AND 2, 2005, : 115 - 121
  • [10] Multisensor fusion for target tracking using sequential Monte Carlo methods
    Vemula, Mahesh