In vivo x-ray phase contrast analyzer-based imaging for longitudinal osteoarthritis studies in guinea pigs

被引:38
|
作者
Coan, Paola [1 ,2 ,3 ,4 ]
Wagner, Andreas [5 ]
Bravin, Alberto [3 ,4 ]
Diemoz, Paul C. [3 ,4 ]
Keyrilainen, Jani [3 ,6 ]
Mollenhauer, Juergen [5 ,7 ,8 ]
机构
[1] Univ Munich, Fac Med, Munich, Germany
[2] Univ Munich, Inst Clin Radiol, Munich, Germany
[3] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[4] Munich Ctr Adv Photon MAP, Munich, Germany
[5] Univ Jena, Dept Orthopaed, Rudolf Elle Hosp Eisenberg, D-6900 Jena, Germany
[6] Univ Helsinki, Cent Hosp, HUCH Canc Ctr, Dept Phys, Helsinki, Finland
[7] Univ Tubingen, NMI, Reutlingen, Germany
[8] TETEC AG, Reutlingen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 24期
关键词
ARTICULAR-CARTILAGE; COMPUTED-TOMOGRAPHY; SYNCHROTRON-RADIATION; REFRACTION; MAMMOGRAPHY; CT; ABSORPTION; KNEE; DEI; RADIOGRAPHY;
D O I
10.1088/0031-9155/55/24/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Over the last two decades phase contrast x-ray imaging techniques have been extensively studied for applications in the biomedical field. Published results demonstrate the high capability of these imaging modalities of improving the image contrast of biological samples with respect to standard absorption-based radiography and routinely used clinical imaging techniques. A clear depiction of the anatomic structures and a more accurate disease diagnosis may be provided by using radiation doses comparable to or lower than those used in current clinical methods. In the literature many works show images of phantoms and excised biological samples proving the high sensitivity of the phase contrast imaging methods for in vitro investigations. In this scenario, the applications of the so-called analyzer-based x-ray imaging (ABI) phase contrast technique are particularly noteworthy. The objective of this work is to demonstrate the feasibility of in vivo x-ray ABI phase contrast imaging for biomedical applications and in particular with respect to joint anatomic depiction and osteoarthritis detection. ABI in planar and tomographic modes was performed in vivo on articular joints of guinea pigs in order to investigate the animals with respect to osteoarthritis by using highly monochromatic x-rays of 52 keV and a low noise detector with a pixel size of 47 x 47 mu m(2). Images give strong evidence of the ability of ABI in depicting both anatomic structures in complex systems as living organisms and all known signs of osteoarthritis with high contrast, high spatial resolution and with an acceptable radiation dose. This paper presents the first proof of principle study of in vivo application of ABI. The technical challenges encountered when imaging an animal in vivo are discussed. This experimental study is an important step toward the study of clinical applications of phase contrast x-ray imaging techniques.
引用
收藏
页码:7649 / 7662
页数:14
相关论文
共 50 条
  • [1] Analyzer-Based Phase Contrast X-ray Imaging for mouse tissues
    Li, H.
    Wang, M.
    Wang, Z.
    Luo, S. Q.
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING: NEW ADVANCES, 2016, : 355 - 358
  • [2] Simulation tools for analyzer-based X-ray phase contrast imaging system with a conventional X-ray source
    Caudevilla, Oriol
    Zhou, Wei
    Stoupin, Stanislav
    Verman, Boris
    Brankov, J. G.
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS V, 2016, 9964
  • [3] Analyzer-based phase-contrast x-ray imaging of carotid plaque microstructure
    Appel, Alyssa A.
    Chou, Cheng-Ying
    Greisler, Howard P.
    Larson, Jeffery C.
    Vasireddi, Sunil
    Zhong, Zhong
    Anastasio, Mark A.
    Brey, Eric M.
    AMERICAN JOURNAL OF SURGERY, 2012, 204 (05): : 631 - 636
  • [4] Source effects in analyzer-based X-ray phase contrast imaging with conventional sources
    Hoennicke, M. G.
    Manica, J.
    Mazzaro, I.
    Cusatis, C.
    Huang, X. -R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (11):
  • [5] A method to extract quantitative information in analyzer-based x-ray phase contrast imaging
    Pagot, E
    Cloetens, P
    Fiedler, S
    Bravin, A
    Coan, P
    Baruchel, J
    Härtwig, J
    Thomlinson, W
    APPLIED PHYSICS LETTERS, 2003, 82 (20) : 3421 - 3423
  • [6] X-ray analyzer-based phase-contrast computed laminography
    Hirano, Keiichi
    Takahashi, Yumiko
    Hyodo, Kazuyuki
    Kimura, Masao
    JOURNAL OF SYNCHROTRON RADIATION, 2016, 23 : 1484 - 1489
  • [7] Analyzer-based phase contrast imaging and phase retrieval using a rotating anode x-ray source
    Vine, D. J.
    Paganin, D. M.
    Pavlov, K. M.
    Kraeusslich, J.
    Wehrhan, O.
    Uschmann, I.
    Foerster, E.
    APPLIED PHYSICS LETTERS, 2007, 91 (25)
  • [8] Limited-angle tomography for analyzer-based phase-contrast x-ray imaging
    Majidi, Keivan
    Wernick, Miles N.
    Li, Jun
    Muehleman, Carol
    Brankov, Jovan G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13): : 3483 - 3500
  • [9] Intrinsic spatial resolution limit of the analyzer-based X-ray phase contrast imaging technique
    Honnicke, Marcelo G.
    Morelhao, Sergio L.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167 (167)
  • [10] Microbubbles as x-ray scattering contrast agents using analyzer-based imaging
    Arfelli, F.
    Rigon, L.
    Menk, R. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (06): : 1643 - 1658