In this work, an artificial heart valve is designed for use in real heart with further consideration on the effect of thrombosis, vorticity, and stress. The design of artificial heart valve model is constructed by Computer-aided design (CAD) modelling and simulated using Computational fluid dynamic (CFD) software. The effect of blood flow pattern, velocity and vorticity of the artificial heart valve design has been analysed in this research work. Based on the results, the artificial heart valve design shows that it has a Doppler velocity index that is less than the allowable standards for the left heart with values of more than 0.30 and less than 2.2. These values are safe to be used as replacement of the human heart valve.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Geometrical design of artificial heart valve based on blood flow analysis around the valve
    Seyed, MR
    Mohammad, RF
    PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 126 - 126
  • [2] Effects of tilting disk heart valve gap width on regurgitant flow through an artificial heart mitral valve
    Maymir, JC
    Deutsch, S
    Meyer, RS
    Geselowitz, DB
    Tarbell, JM
    ARTIFICIAL ORGANS, 1997, 21 (09) : 1014 - 1025
  • [3] Simulation of Blood flow in Different Configurations Design of Bi-leaflet Mechanical Heart Valve
    Mokhtar, N. Hafizah
    Abas, Aizat
    INTERNATIONAL CONFERENCE ON AEROSPACE AND MECHANICAL ENGINEERING (AEROMECH17), 2018, 370
  • [4] Numerical simulation of the performance of an artificial heart valve
    Zakharov, Yurii N.
    Dolgov, Dmitry A.
    Shokin, Yurii I.
    RUSSIAN JOURNAL OF NUMERICAL ANALYSIS AND MATHEMATICAL MODELLING, 2016, 31 (04) : 229 - 238
  • [5] THE DYNAMIC SIMULATION OF FLOW THROUGH A TISSU ENGINEERED BILEAFLET HEART VALVE
    Liu, Kunlun
    Barocas, Victor H.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE 2008, PTS A AND B, 2009, : 1099 - 1100
  • [6] In vitro flow analysis of artificial heart valve
    Owida, AA
    Morsi, Y
    Sakhaeimanesh, A
    COMPUTATIONAL MECHANICS, VOLS 1 AND 2, PROCEEDINGS: NEW FRONTIERS FOR THE NEW MILLENNIUM, 2001, : 893 - 898
  • [7] Computer and experimental modelling of blood flow through the mitral valve of the heart
    Al-Atabi M.
    Espino D.M.
    Hukins D.W.L.
    Journal of Biomechanical Science and Engineering, 2010, 5 (01): : 78 - 84
  • [8] AORTIC BLOOD-FLOW VELOCITY IN LEFT HEART-VALVE DYSFUNCTION
    FRICKE, GR
    MATTERN, HJ
    CIRCULATION, 1978, 58 (04) : 191 - 191
  • [9] USING ATLAS OF HEART SHAPES FOR SIMULATION OF BLOOD FLOW IN LEFT VENTRICLE
    Moosavi, Mir-Hossein
    Fatouraee, Nasser
    Katoozian, Hamid
    Pashaei, Ali
    Frangi, Alejandro F.
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2013, 25 (06):
  • [10] TRANSIENT FLOW FIELD SIMULATION THROUGH A MECHANICAL TRILEAFLET HEART VALVE PROSTHESIS
    Linde, T.
    Kaufmann, T.
    Cuenca-Navalon, E.
    Schmitz, C.
    Schmitz-Rode, T.
    Steinseifer, U.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2008, 31 (07): : 604 - 604