Calibration of near-infrared transfer standards at optical-fibre communication wavelengths by direct comparison with a cryogenic radiometer

被引:16
|
作者
Corredera, P [1 ]
Campos, J [1 ]
Hernanz, ML [1 ]
Fontecha, JL [1 ]
Pons, A [1 ]
Corróns, A [1 ]
机构
[1] CSIC, Inst Fis Aplicada, Madrid, Spain
关键词
D O I
10.1088/0026-1394/35/4/10
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper describes an experimental setup, based on an optical-fibre system, to calibrate infrared photodiodes at 1300 nm and 1550 nm by comparison with a cryogenic radiometer. An integrating-sphere radiometer used as a transfer standard for optical-fibre power measurements has been characterized and calibrated, obtaining an uncertainty of less than 0.1% at these wavelengths.
引用
收藏
页码:273 / 277
页数:5
相关论文
共 17 条
  • [1] Calibration of near-infrared transfer standards at optical-fibre communication wavelengths by direct comparison with a cryogenic radiometer
    Corredera, P.
    Campos, J.
    Hernanz, M.L.
    Fontecha, J.L.
    Pons, A.
    Carrons, A.
    Metrologia, 35 (04): : 273 - 277
  • [2] Calibration of a visible and near-infrared portable transfer radiometer
    Biggar, SF
    METROLOGIA, 1998, 35 (04) : 701 - 706
  • [3] Cryogenic radiometer based absolute spectral power responsivity calibration of integrating sphere radiometer to be used in power measurements at optical fiber communication wavelengths
    Çelikel, O
    Bazkir, Ö
    Küçükoglu, M
    Samedov, F
    OPTICAL AND QUANTUM ELECTRONICS, 2005, 37 (06) : 529 - 543
  • [4] Cryogenic radiometer based absolute spectral power responsivity calibration of integrating sphere radiometer to be used in power measurements at optical fiber communication wavelengths
    Oğuz Çelikel
    Özcan Bazkir
    Mehmet Küçükoğlu
    Farhad Samedov
    Optical and Quantum Electronics, 2005, 37 : 529 - 543
  • [5] High accuracy measurement of the absolute spectral responsivity of Ge and InGaAs trap detectors by direct calibration against an electrically calibrated cryogenic radiometer in the near-infrared
    Lopez, M.
    Hofer, H.
    Kueck, S.
    METROLOGIA, 2006, 43 (06) : 508 - 514
  • [6] Comparison of near-infrared and mid-infrared link budgets for optical satellite communication
    Flannigan, Liam
    Xu, Chang-qing
    2022 PHOTONICS NORTH (PN), 2022,
  • [7] Scalable calibration transfer without standards via dynamic time warping for near-infrared spectroscopy
    Zou, Congming
    Zhu, Huimin
    Shen, Junru
    He, Yue
    Su, Jiaen
    Fan, Xiaqiong
    Lu, Hongmei
    Zhang, Zhimin
    Chen, Yi
    ANALYTICAL METHODS, 2019, 11 (35) : 4481 - 4493
  • [8] INTERCOMPARISON BETWEEN 2 INDEPENDENT PRIMARY RADIOMETRIC STANDARDS IN THE VISIBLE AND NEAR-INFRARED - A CRYOGENIC RADIOMETER AND THE ELECTRON STORAGE RING BESSY
    FOX, NP
    KEY, PJ
    RIEHLE, F
    WENDE, B
    APPLIED OPTICS, 1986, 25 (14): : 2409 - 2420
  • [9] Experimental comparison between far- and near-infrared wavelengths in free-space optical systems
    Colvero, CP
    Cordeiro, MCR
    de Faria, GV
    von der Weid, JP
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2005, 46 (04) : 319 - 323
  • [10] Transfer of near infrared calibration for gasoline octane number based on screening consistent wavelengths combined with direct standardization algorithm
    Wang, Honghong
    Yuan, Hui
    Xiong, Zhixin
    JOURNAL OF NEAR INFRARED SPECTROSCOPY, 2024, 32 (1-2) : 38 - 45