In Vivo Testing of Knee Stability After Rotating-hinge Total Knee Arthroplasty: A Comparison of 2 Knee Systems

被引:2
|
作者
Friesenbichler, Joerg [1 ]
Glehr, Mathias [1 ]
Sadoghi, Patrick [1 ]
Maurer-Ertl, Werner [1 ]
Ott, Florian [1 ]
Leithner, Andreas [1 ]
机构
[1] Med Univ Graz, Dept Orthopaed Surg, A-8036 Graz, Austria
关键词
ENDOPROSTHETIC RECONSTRUCTIONS; TUMOR ENDOPROSTHESES; LIMB SALVAGE; BONE SARCOMA; FOLLOW-UP; MALIGNANT-TUMORS; REVISION SURGERY; PROXIMAL TIBIA; DISTAL FEMUR; REPLACEMENT;
D O I
10.3928/01477447-20120222-20
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Rotating-hinge knee prostheses are used for reconstruction in cases of severe articular compromise and major bone loss. Biomechanical studies revealed that rotating-hinge designs with long and cylindrical pegs are more stable than devices with short and more tapered ones. Twenty-five patients underwent clinical examination using ultrasound, radiographs, and 3 different rating systems to examine the in vivo stability and functional outcome of 2 rotating-hinge knee systems. Overall, the study revealed that a stable reconstruction could be achieved with both tested devices, with good functional outcome. The results for medial and lateral liftoff during flexion and extension in ultrasonography were comparable, whereas the measured distraction of the Limb Preservation System (LPS/M.B.T.; DePuy, Warsaw, Indiana) was lower compared with the S-ROM Noiles prostheses (DePuy). The implant, the new formed capsule, and the remaining soft tissues have to maintain joint stability. Soft tissue reconstruction, especially the medial gastrocnemius flap, and the newly formed periprosthetic scar seems to prevent distraction of several millimeters. In addition, determining the lift-off with ultrasonography showed that the shape of the peg does not influence implant's stability against lateral directed forces.
引用
收藏
页码:E335 / E342
页数:8
相关论文
共 50 条
  • [1] Rotating-hinge Total Knee for Revision Total Knee Arthroplasty
    Bistolfi, Alessandro
    Massazza, Giuseppe
    Rosso, Federica
    Crova, Maurizio
    ORTHOPEDICS, 2012, 35 (03) : E325 - E330
  • [2] KINEMATIC ROTATING-HINGE TOTAL KNEE ARTHROPLASTY
    RAND, JA
    CHAO, EYS
    STAUFFER, RN
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (04): : 489 - 497
  • [3] Dislocation of rotating-hinge total knee arthroplasty
    Encinas-Ullan, Carlos A.
    Gomez-Cardero, Primitivo
    Ruiz-Perez, Juan S.
    Carlos Rodriguez-Merchan, E.
    EFORT OPEN REVIEWS, 2021, 6 (02) : 107 - 112
  • [4] Endo-Modell Rotating-hinge Total Knee for Revision Total Knee Arthroplasty
    Bistolfi, Alessandro
    Rosso, Federica
    Crova, Maurizio
    Massazza, Giuseppe
    ORTHOPEDICS, 2013, 36 (10) : E1299 - E1306
  • [5] Outcomes of Rotating-hinge Total Knee Arthroplasty Following Complex Primary and Revision Total Knee Arthroplasty
    Pfeufer, Daniel
    Gililland, Jeremy
    Anderson, Mike B.
    Monteiro, Priscila
    Peters, Christopher L.
    Stagg, Marissa
    Pelt, Christopher E.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2021, 38
  • [6] Indications for primary rotating-hinge total knee arthroplasty. Is there consensus?
    Dauwe, Jan
    Vandenneucker, Hilde
    ACTA ORTHOPAEDICA BELGICA, 2018, 84 (03): : 245 - 250
  • [7] Rotating-Hinge Revision Total Knee Arthroplasty for Treatment of Severe Arthrofibrosis
    Bingham, Joshua S.
    Bukowski, Brandon R.
    Wyles, Cody C.
    Pareek, Ayoosh
    Berry, Daniel J.
    Abdel, Matthew P.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (07): : S271 - S276
  • [8] A case of an atraumatic implant failure after primary rotating-hinge total knee arthroplasty
    Petitqueux, Lucas
    Verhulst, Karen
    Dauwe, Jan
    Dauwe, Dirk
    ACTA ORTHOPAEDICA BELGICA, 2021, 87 (03): : 449 - 451
  • [9] Primary total knee arthroplasty with rotating-hinge prosthesis in severely compromised knees
    Leng, Yi
    Zeng, Min
    Hu, Yihe
    Zhu, Jianxi
    Su, Weiping
    Xie, Jie
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (06): : 5867 - 5872
  • [10] Condylar failure of the Lacey Rotating-Hinge total knee
    Scott, CE
    Heiner, J
    Worzala, FJ
    Vanderby, R
    JOURNAL OF ARTHROPLASTY, 1996, 11 (02): : 214 - 216