Analysis of 60 pharmaceuticals and personal care products in sewage sludge by ultra-high performance liquid chromatography and tandem mass spectroscopy

被引:6
|
作者
Perez-Lemus, N. [1 ,2 ,3 ]
Lopez-Serna, R. [1 ,3 ]
Perez-Elvira, S. I. [2 ,3 ]
Barrado, E. [1 ,3 ]
机构
[1] Univ Valladolid, Fac Sci, Dept Analyt Chem, Campus Miguel Delibes,Paseo Belen 7, Valladolid 47011, Spain
[2] Univ Valladolid, Sch Ind Engn, Dept Chem Engn & Environm Technol, Dr Mergelina S-N, Valladolid 47011, Spain
[3] Inst Sustainable Proc, Dr Mergelina S-N, Valladolid 47011, Spain
关键词
LC-MS; MS; Compounds of emerging concern (CECs); Target analysis; High throughput; Green chemistry; Triple quadrupole; SOLID-PHASE EXTRACTION; MULTI-RESIDUE ANALYSIS; WASTE-WATER TREATMENT; EMERGING CONTAMINANTS; ASSISTED EXTRACTION; AQUATIC ENVIRONMENT; TREATMENT PLANTS; ILLICIT DRUGS; SPECTROMETRY; ANTIBIOTICS;
D O I
10.1016/j.microc.2021.107148
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a comparison of three different analytical proposals for the determination of 60 pharmaceuticals and personal care products (PPCPs) in solid urban sewage sludge. Two fast sample pretreatments, i.e., online solid-phase-extraction (online SPE) and direct injection (DI), were tested against the conventional offline solid phase extraction (offline SPE). In all cases, subsequently, extracts underwent ultra-high-performance-liquid chromatography coupled to tandem-mass-spectrometry (UHPLC-MS/MS), simultaneously operating in both positive and negative electrospray ionization (ESI) mode. In addition, as solid matrices, clean-up steps were necessarily preceded by ultra-sound-assisted extraction (UAE) in all cases. Matrix-matched quantification was combined with internal standard providing high reliability to all three approaches. Best performance was observed for the fully automatized and non-pretreated DI method, showing limits of detection below 30 ng g-1 for many of the target compounds, and recoveries between 80 and 120%. Finally, the best working method was validated and applied to the analysis of PPCPs in different dewatered digested sludge samples from the wastewater treatment plant (WWTP) in Valladolid (Spain). Acetaminophen was found at concentrations above 1,000 ng g 1.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Determination of personal care products in sewage sludge by pressurized liquid extraction and ultra high performance liquid chromatography-tandem mass spectrometry
    Nieto, Antonio
    Borrull, Francesc
    Maria Marce, Rosa
    Pocurull, Eva
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (30) : 5619 - 5625
  • [2] Determination of pharmaceuticals, steroid hormones, and endocrine-disrupting personal care products in sewage sludge by ultra-high-performance liquid chromatography–tandem mass spectrometry
    Yiyi Yu
    Qiuxin Huang
    Jianlan Cui
    Kun Zhang
    Caiming Tang
    Xianzhi Peng
    Analytical and Bioanalytical Chemistry, 2011, 399 : 891 - 902
  • [3] Determination of pharmaceuticals, steroid hormones, and endocrine-disrupting personal care products in sewage sludge by ultra-high-performance liquid chromatography-tandem mass spectrometry
    Yu, Yiyi
    Huang, Qiuxin
    Cui, Jianlan
    Zhang, Kun
    Tang, Caiming
    Peng, Xianzhi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (02) : 891 - 902
  • [4] Simultaneous determination of 18 pharmaceuticals and personal care products in surface water by ultra-high performance liquid chromatography-tandem mass spectrometry
    Zhu Saichang
    Wang Jing
    Shao Weiwei
    Chen Hong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (01) : 15 - 21
  • [5] Determination of personal care products and pharmaceuticals in environmental samples in Spain and Colombia by ultra-high performance liquid-chromatography-tandem mass spectrometry
    Marian Martinez, Jennie
    Antonio Penuela, Gustavo
    Gracia-Lord, Emma
    Sancho, Juan V.
    Hernandez, Felix
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [6] Multi-class determination of personal care products and pharmaceuticals in environmental and wastewater samples by ultra-high performance liquid-chromatography-tandem mass spectrometry
    Gracia-Lor, Emma
    Martinez, Marian
    Sancho, Juan V.
    Penuela, Gustavo
    Hernandez, Felix
    TALANTA, 2012, 99 : 1011 - 1023
  • [7] Pressurised liquid extraction and ultra-high performance liquid chromatography-tandem mass spectrometry to determine endogenous and synthetic glucocorticoids in sewage sludge
    Herrero, P.
    Borrull, F.
    Marce, R. M.
    Pocurull, E.
    TALANTA, 2013, 103 : 186 - 193
  • [8] Determination of 145 pharmaceuticals and personal care products in eleven categories in water by ultra-high performance liquid chromatography-triple quadrupole mass spectrometry
    Sun Huijing
    Zhang Beibei
    Cui Dongni
    Dong Bingjie
    Wang Hui
    Hu Guanjiu
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2024, 42 (01) : 24 - 37
  • [9] Analysis of endocrine disrupting compounds, pharmaceuticals and personal care products in sewage sludge by gas chromatography-mass spectrometry
    Yu, Yong
    Wu, Laosheng
    TALANTA, 2012, 89 : 258 - 263
  • [10] Determination of the Concentrations of 176 Pharmaceutical and Personal Care Products in Drinking Water Samples by Ultra-high Performance Liquid Chromatography-Tandem Mass Spectrometry
    Wu, Shaoming
    Liu, Wenjing
    Dai, Ming
    He, Menghang
    Chen, Yankai
    Wang, Zheng
    Zhan, Chongqing
    Ouyang, Liqun
    Shipin Kexue/Food Science, 2024, 45 (04): : 307 - 314