Dynamic in-vivo assessment of navicular drop while running in barefoot, minimalist, and motion control footwear conditions

被引:25
|
作者
Hoffman, Scott E. [1 ]
Peltz, Cathryn D. [1 ]
Haladik, Jeffrey A. [1 ]
Divine, George [2 ]
Nurse, Matthew A. [3 ]
Bey, Michael J. [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Orthopaed Surg, Ctr Bone & Joint, E&R 2015, Detroit, MI 48202 USA
[2] Henry Ford Hlth Syst, Dept Publ Hlth Sci, Detroit, MI 48202 USA
[3] Nike Inc, Nike Sport Res Lab, Beaverton, OR USA
关键词
Navicular drop; Pronation; Barefoot running; Minimalist shoe; Dynamic X-ray; Foot posture; MEDIAL LONGITUDINAL ARCH; VALIDATION; PRONATION; INJURIES; TRACKING; RUNNERS; POSTURE; RISK;
D O I
10.1016/j.gaitpost.2015.02.017
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Running-related injuries are common and previous research has suggested that the magnitude and/or rate of pronation may contribute to the development of these injuries. Accurately and directly measuring pronation can be challenging, and therefore previous research has often relied on navicular drop (under both static and dynamic conditions) as an indirect assessment of pronation. The objectives of this study were to use dynamic, biplane X-ray imaging to assess the effects of three footwear conditions (barefoot, minimalist shoes, motion control shoes) on the magnitude and rate of navicular drop during running, and to determine the association between static and dynamic measures of navicular drop. Twelve healthy distance runners participated in this study. The magnitude and rate of navicular drop were determined by tracking the 3D position of the navicular from biplane radiographic images acquired at 60 Hz during the stance phase of overground running. Static assessments of navicular drop and foot posture were also recorded in each subject. Footwear condition was not found to have a significant effect on the magnitude of navicular drop (p = 0.22), but motion control shoes had a slower navicular drop rate than running barefoot (p = 0.05) or in minimalist shoes (p = 0.05). In an exploratory analysis, static assessments of navicular drop and foot posture were found to be poor predictors of dynamic navicular drop in all footwear conditions (p > 0.18). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:825 / 829
页数:5
相关论文
共 5 条
  • [1] The interaction effect of different footwear types and static navicular drop or dynamic ankle pronation on the joint stiffness of the lower limb during running
    Esmaeili, Ali
    Hosseininejad, Sayed Esmaeil
    Jafarnezhadgero, Amirali
    Dionisio, Valdeci Carlos
    GAIT & POSTURE, 2024, 108 : 28 - 34
  • [2] A minimal markerset for three-dimensional foot function assessment: measuring navicular drop and drift under dynamic conditions
    Eichelberger, Patric
    Blasimann, Angela
    Lutz, Nicole
    Krause, Fabian
    Baur, Heiner
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2018, 11
  • [3] A minimal markerset for three-dimensional foot function assessment: measuring navicular drop and drift under dynamic conditions
    Patric Eichelberger
    Angela Blasimann
    Nicole Lutz
    Fabian Krause
    Heiner Baur
    Journal of Foot and Ankle Research, 11
  • [4] Dynamic navicular motion measured using a stretch sensor is different between walking and running, and between over-ground and treadmill conditions
    Christian J Barton
    Simon L Kappel
    Peter Ahrendt
    Ole Simonsen
    Michael S Rathleff
    Journal of Foot and Ankle Research, 8
  • [5] Dynamic navicular motion measured using a stretch sensor is different between walking and running, and between over-ground and treadmill conditions
    Barton, Christian J.
    Kappel, Simon L.
    Ahrendt, Peter
    Simonsen, Ole
    Rathleff, Michael S.
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2015, 8