Patient Characteristics Associated With Artifacts in Spectralis Optical Coherence Tomography Imaging of the Retinal Nerve Fiber Layer in Glaucoma

被引:97
|
作者
Liu, Yingna [1 ]
Simavli, Huseyin [1 ,2 ]
Que, Christian John [1 ,2 ]
Rizzo, Jennifer L. [2 ]
Tsikata, Edem [1 ,2 ]
Maurer, Rie [1 ,3 ]
Chen, Teresa C. [1 ,2 ]
机构
[1] Harvard Univ, Sch Med, Boston, MA USA
[2] Massachusetts Eye & Ear Infirm, Dept Ophthalmol, Boston, MA 02114 USA
[3] Brigham & Womens Hosp, Ctr Clin Invest, Boston, MA 02115 USA
基金
美国医疗保健研究与质量局; 美国国家卫生研究院;
关键词
PARAPAPILLARY CHORIORETINAL ATROPHY; THICKNESS MEASUREMENTS; EYES; QUALITY; MYOPIA; VARIABILITY; CHINESE; NUMBER;
D O I
10.1016/j.ajo.2014.12.006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To determine patient factors and eye conditions associated with artifacts in Spectralis optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) scans. DESIGN: Retrospective cross-sectional study. METHODS: The prevalence of 12 artifact types were described in this review of 2313 eye scans from 1188 patients who underwent a complete eye examination with Spectralis OCT scanning during the period of September 2009 to July 2013. The generalized estimating equations model was used to analyze associations between increased artifact prevalence and 10 patient characteristics, which included age, sex, race, visual acuity, refractive error, astigmatism, cataract status, glaucoma staging, visual field reliability, and glaucoma diagnosis. RESULTS: A total of 1070 or 46.3% of the 2313 eye scans had at least 1 artifact. Decentration error was the most common artifact (27.8%), followed by posterior vitreous detachment artifacts (14.4%). Visual acuity of less than 20/40 (P < .0001), presence of moderate to severe cataracts (P < .0001), advanced stage of glaucoma (P < .0001), and a diagnosis of open-angle glaucoma (P = .0003) were associated with increased prevalence of artifacts. CONCLUSIONS: Clinicians should first assess scans for artifacts before making therapeutic decisions based on RNFL thickness measurements. (C) 2015 by Elsevier Inc. All rights reserved.
引用
收藏
页码:565 / 576
页数:12
相关论文
共 50 条
  • [1] Evaluation of myopia on retinal nerve fiber layer thickness measured by Spectralis optical coherence tomography
    Zha, Yi
    Zhuang, Jinfei
    Lin, Da
    Feng, Wangqiang
    Zheng, Haihua
    Cai, Jianqiu
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (03) : 2716 - 2720
  • [2] Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography Analysis of the Retinal Nerve Fiber Layer Map for Glaucoma Detection
    Leung, Christopher K. S.
    Lam, Shi
    Weinreb, Robert N.
    Liu, Shu
    Ye, Cong
    Liu, Lan
    He, Jing
    Lai, Gilda W. K.
    Li, Taiping
    Lam, Dennis S. C.
    OPHTHALMOLOGY, 2010, 117 (09) : 1684 - 1691
  • [3] Additive Diagnostic Role of Imaging in Glaucoma: Optical Coherence Tomography and Retinal Nerve Fiber Layer Photography
    Kim, Ko Eun
    Kim, Seok Hwan
    Oh, Sohee
    Jeoung, Jin Wook
    Suh, Min Hee
    Seo, Je Hyun
    Kim, Martha
    Park, Ki Ho
    Kim, Dong Myung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (12) : 8024 - 8030
  • [4] Impact of Artifacts From Optical Coherence Tomography Retinal Nerve Fiber Layer and Macula Scans on Detection of Glaucoma Progression
    Li, Ang
    Thompson, Atalie C.
    Asrani, Sanjay
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 221 : 235 - 245
  • [5] A comparison of optical coherence tomography and retinal nerve fiber layer photography for detection of nerve fiber layer damage in glaucoma
    Zangwill, LM
    Williams, J
    Berry, CC
    Knauer, S
    Weinreb, RN
    OPHTHALMOLOGY, 2000, 107 (07) : 1309 - 1315
  • [6] Optical coherence tomography longitudinal evaluation of retinal nerve fiber layer thickness in glaucoma
    Wollstein, G
    Schuman, JS
    Price, LL
    Aydin, A
    Stark, PC
    Hertzmark, E
    Lai, E
    Ishikawa, H
    Mattox, C
    Fujimoto, JG
    Paunescu, LA
    ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (04) : 464 - 470
  • [7] Retinal Nerve Fiber Layer Detection at Optical Coherence Tomography Image for the Diagnosis of Glaucoma
    Sahin, Mehmet Erhan
    Bozkurt, Mehmet Recep
    2015 MEDICAL TECHNOLOGIES NATIONAL CONFERENCE (TIPTEKNO), 2015,
  • [8] Diagnostic Ability of Retinal Nerve Fiber Layer Imaging by Swept-Source Optical Coherence Tomography in Glaucoma
    Yang, Zhiyong
    Tatham, Andrew J.
    Zangwill, Linda M.
    Weinreb, Robert N.
    Zhang, Chunwei
    Medeiros, Felipe A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (01) : 193 - 201
  • [9] Pulsatile retinal nerve fiber layer imaging with functional optical coherence tomography
    An, Lin
    Yan, Bixuan
    Zhao, Yansong
    He, Ke
    Wu, Xiaocui
    Lan, Gongpu
    Huang, Yanping
    Xu, Jingjiang
    Ou, Chubin
    Zeng, Xi
    Wang, Shuna
    Wang, Xiaoli
    Long, Jinfeng
    Wei, Xunbin
    Qin, Jia
    OPTICS CONTINUUM, 2022, 1 (02): : 283 - 296
  • [10] Effect of Refractive Correction Error on Retinal Nerve Fiber Layer Thickness: A Spectralis Optical Coherence Tomography Study
    Ma, Xiaoli
    Chen, Yutong
    Liu, Xianjie
    Ning, Hong
    MEDICAL SCIENCE MONITOR, 2016, 22 : 5181 - 5189