The effect of density and atomic number of collimator on SPECT image quality in high energy

被引:0
|
作者
Rajaee, A. [1 ,2 ,3 ]
Shahriari, M. [4 ]
Asl, A. Kamali [4 ]
Alaf, M. Athari [2 ]
机构
[1] Islamic Azad Univ, Plasma Phys Res Ctr, Tehran, Iran
[2] Islamic Azad Univ, Dept Sci, Tehran, Iran
[3] Islamic Azad Univ, Res Branch, Tehran, Iran
[4] Beheshti Univ, Nucl Engn Dept Shahid, Tehran, Iran
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:S128 / S128
页数:1
相关论文
共 50 条
  • [1] Comparison of Image Quality According to Collimator, Distance, Acquisition Time in SPECT
    Kim, C.
    Park, H.
    Kim, B.
    Kim, Y.
    Kim, J.
    Kong, K.
    Seo, M.
    Seo, B.
    Lyu, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S521 - S521
  • [2] A Parallel-Cone Collimator for High-Energy SPECT
    Beijst, Casper
    Elschot, Mattijs
    Viergever, Max A.
    de Jong, Hugo W. A. M.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03) : 476 - 482
  • [3] Comparison of collimator choice on image quality of I-131 in SPECT/CT
    Kim, Jung Yul
    Kim, Joo Yeon
    Kang, Chun Goo
    Nam-Koong, Hyuk
    Kim, Jae Sam
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [4] Use of a fanbeam collimator to improve image quality in small field of view SPECT
    Anderson, DC
    Wells, RG
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1838 - 1841
  • [5] Comparison of collimator choice on image quality of I-131 in SPECT/CT
    Kim, Jung Yul
    Kim, Joo Yeon
    Kang, Chun Goo
    Nam-Koong, Hyuk
    Kim, Jae Sam
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [6] Effect of detector energy response on image quality of myocardial perfusion SPECT
    Volokh, Lana
    Hugg, James
    Blevis, Ira
    Asma, Evren
    Jansen, Floris
    Manjeshwar, Ravindra
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3318 - +
  • [7] Comparative study of GFR measured by SPECT/CT with low energy high resolution collimator and low energy general resolution collimator
    Qi, Chi
    Chen, Yue
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [8] A simple image based method for obtaining electron density and atomic number in dual energy CT
    Szczykutowicz, Timothy P.
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [9] EFFECT OF COLLIMATOR MOTION ON IMAGE QUALITY IN NUCLEAR-MEDICINE
    DOWDEY, JE
    MURRY, RC
    BONTE, FJ
    RADIOLOGY, 1975, 114 (02) : 411 - 414
  • [10] Evaluation of a collimator-detector response compensation method in SPECT images. Comparison of image quality with "Brain SPECT" and Evolution™
    Fall, S.
    Bailly, P.
    Meyer, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S269 - S269