Calibration of Planar Reflectors Reshaping LiDAR's Field of View

被引:3
|
作者
Pelka, Michal [1 ]
Bedkowski, Janusz [2 ]
机构
[1] Tooploox, PL-53601 Wroclaw, Poland
[2] Polish Acad Sci, Inst Fundamental Technol Res, PL-02106 Warsaw, Poland
关键词
LiDAR; ICP; mapping; calibration; reshape field of view; solid state LiDAR; REGISTRATION;
D O I
10.3390/s21196501
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper describes the calibration method for calculating parameters (position and orientation) of planar reflectors reshaping LiDAR's (light detection and ranging) field of view. The calibration method is based on the reflection equation used in the ICP (Iterative Closest Point) optimization. A novel calibration process as the multi-view data registration scheme is proposed; therefore, the poses of the measurement instrument and parameters of planar reflectors are calculated simultaneously. The final metric measurement is more accurate compared with parameters retrieved from the mechanical design. Therefore, it is evident that the calibration process is required for affordable solutions where the mechanical design can differ from the inaccurate assembly. It is shown that the accuracy is less than 20 cm for almost all measurements preserving long-range capabilities. The experiment is performed based on Livox Mid-40 LiDAR augmented with six planar reflectors. The ground-truth data were collected using Z + F IMAGER 5010 3D Terrestrial Laser Scanner. The calibration method is independent of mechanical design and does not require any fiducial markers on the mirrors. This work fulfils the gap between rotating and Solid-State LiDARs since the field of view can be reshaped by planar reflectors, and the proposed method can preserve the metric accuracy. Thus, such discussion concludes the findings. We prepared an open-source project and provided all the necessary data for reproducing the experiments. That includes: Complete open-source code, the mechanical design of reflector assembly and the dataset which was used in this paper.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Reshaping Field of View and Resolution with Segmented Reflectors: Bridging the Gap between Rotating and Solid-State LiDARs
    Aalerud, Atle
    Dybedal, Joacim
    Subedi, Dipendra
    SENSORS, 2020, 20 (12) : 1 - 26
  • [2] Calibration between a panoramic LiDAR and a limited field-of-view depth camera
    Tang, Weijie
    Wang, Bin
    Huang, Longxiang
    Yang, Xu
    Zhang, Qian
    Zhu, Sulei
    Ma, Yan
    COMPLEX & INTELLIGENT SYSTEMS, 2025, 11 (01)
  • [3] FIELD REFLECTANCE CALIBRATION WITH GREY STANDARD REFLECTORS
    PHILIPSON, WR
    GORDON, DK
    PHILPOT, WD
    DUGGIN, MJ
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 1989, 10 (06) : 1035 - 1039
  • [4] Calibration of Camera with Large Field-of-View Based on Flexible Planar Target
    Ju Huo
    Wen-Bo Dong
    Ning Yang
    Wu-Kang Lin
    Journal of Harbin Institute of Technology(New series), 2013, (04) : 14 - 20
  • [5] Calibration of Camera with Large Field-of-View Based on Flexible Planar Target
    Ju Huo
    WenBo Dong
    Ning Yang
    WuKang Lin
    Journal of Harbin Institute of Technology, 2013, 20 (04) : 14 - 20
  • [7] Extrinsic Calibration and Verification of Multiple Non-overlapping Field of View Lidar Sensors
    Das, Sandipan
    Mahabadi, Navid
    Djikic, Addi
    Nassir, Cesar
    Chatterjee, Saikat
    Fallon, Maurice
    2022 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA 2022), 2022,
  • [8] Wide field of view imaging with parabolic cylindrical reflectors
    Bunton, John D.
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2006, 54 (07) : 2131 - 2136
  • [9] Lidar equation modification for large field of view scannerless lidar
    Liu, Jinbo
    Li, Sining
    Wang, Qian
    Li, Huizi
    Wang, Qi
    Guang, Yuhao
    LFNM 2006: 8TH INTERNATIONAL CONFERENCE ON LASER AND FIBER-OPTICAL NETWORKS MODELING, PROCEEDINGS, 2006, : 73 - 75
  • [10] Modification of lidar equation in large field of view
    National Key Laboratory of Tunable Laser Technology, Harbin Institute of Technology, Harbin 150001, China
    Zhongguo Jiguang, 2006, SUPPL. (108-110):