With rapid development of micro fabrication technology, the production level of micro inertial devices has increased, which promoted the performance improvement of Micro Inertial Measurement Unit (MIMU). Measurement precision of MIMU is one of the most significant indexes, especially for the application of the guided spinning projectiles. In order to improve the measurement precision of MIMU, this paper presents a novel calibration method. The calibration model is established and the derivation for parameters estimation has been introduced. By the multirate tests and multiposition tests, all the parameters in the calibration model can be well estimated. Verification experiment shows that the proposed method has the same compensation effect as the traditional method, but it can alleviate the computing burden for the system. Thus the proposed method will have a wide application prospect for the future engineering calibration.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Calibration compensation method for micro inertial measurement unit based on MEMS
    School of Instrument Science and Opto-Electronics Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100083, China
    Beijing Hangkong Hangtian Daxue Xuebao, 2008, 4 (439-442): : 439 - 442
  • [2] Research on the temperature compensation method for Micro Inertial Measurement Unit
    Wang Dan
    Gao Guowei
    Cui Fangwei
    Song Zhen
    COMPUTING, CONTROL AND INDUSTRIAL ENGINEERING IV, 2013, 823 : 228 - 231
  • [3] Network dynamic field calibration for micro inertial measurement unit
    Xu Yun
    Su Yan
    Zhu Xinhua
    Luo Zhihang
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2019, 41 (10) : 2826 - 2837
  • [4] CALIBRATION OF AN INERTIAL MEASUREMENT UNIT
    Paternain, Santiago
    Tailanian, Matias
    Canetti, Rafael
    2013 16TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS (ICAR), 2013,
  • [5] Calibration of an Inertial Measurement Unit
    Avrutov V.V.
    Sapegin A.N.
    Stefanishin Z.S.
    Tsisarzh V.V.
    International Applied Mechanics, 2017, 53 (2) : 228 - 236
  • [6] Research on Static Decoupling Method of Non-Gyro Micro Inertial Measurement Unit
    Ding, Mingli
    Yang, Dongmei
    Zhao, Jindong
    Zhuang, Lili
    COMPUTER AND COMPUTING TECHNOLOGIES IN AGRICULTURE V, PT I, 2012, 368 : 54 - 64
  • [7] Evaluation and Calibration of an Inertial Measurement Unit
    Pervez, Md. Riaz
    Ahamed, Hafiz
    Islam, Md. Manirul
    Hille, Christof
    Roth, Hubert
    8TH BSME INTERNATIONAL CONFERENCE ON THERMAL ENGINEERING, 2019, 2121
  • [8] Automatic Calibration for Inertial Measurement Unit
    Cheuk, Chi Ming
    Lau, Tak Kit
    Lin, Kai Wun
    Liu, Yunhui
    2012 12TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS & VISION (ICARCV), 2012, : 1341 - 1346
  • [9] Factorization-based calibration method for MEMS inertial measurement unit
    Hwangbo, Myung
    Kanade, Takeo
    2008 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-9, 2008, : 1306 - 1311
  • [10] Development of a High-Precision Calibration Method for Inertial Measurement Unit
    Kim, Moon-Sik
    Yu, Si-Bok
    Lee, Kwang-Soo
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2014, 15 (03) : 567 - 575