Computational wear prediction of artificial knee joints based on a new wear law and formulation

被引:79
|
作者
Abdelgaied, Abdellatif [1 ]
Liu, Feng [1 ]
Brockett, Claire [1 ]
Jennings, Louise [1 ]
Fisher, John [1 ]
Jin, Zhongmin [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Inst Med & Biol Engn, Leeds LS2 9JT, W Yorkshire, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
Ultra-high molecular weight polyethylene; Artificial knee joints; Wear prediction; Wear mechanism; Wear coefficient; Creep; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL HIP-ARTHROPLASTY; CONTACT STRESS; REPLACEMENT WEAR; CROSS-SHEAR; UHMWPE; PROSTHESES; SIMULATION; KINEMATICS; IMPLANTS;
D O I
10.1016/j.jbiomech.2011.01.027
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Laboratory joint wear simulator testing has become the standard means for preclinical evaluation of wear resistance of artificial knee joints. Recent simulator designs have been advanced and become successful at reproducing the wear patterns observed in clinical retrievals. However, a single simulator test can be very expensive and take a long time to run. On the other hand computational wear modelling is an alternative attractive solution to these limitations. Computational models have been used extensively for wear prediction and optimisation of artificial knee designs. However, all these models have adopted the classical Archard's wear law, which was developed for metallic materials, and have selected wear factors arbitrarily. It is known that such an approach is not generally true for polymeric bearing materials and is difficult to implement due to the high dependence of the wear factor on the contact pressure. Therefore, these studies are generally not independent and lack general predictability. The objective of the present study was to develop a new computational wear model for the knee implants, based on the contact area and an independent experimentally determined non-dimensional wear coefficient. The effects of cross-shear and creep on wear predictions were also considered. The predicted wear volume was compared with the laboratory simulation measurements. The model was run under two different kinematic inputs and two different insert designs with curved and custom designed flat bearing surfaces. The new wear model was shown to be capable of predicting the difference of the wear volume and wear pattern between the two kinematic inputs and the two tibial insert designs. Conversely, the wear factor based approach did not predict such differences. The good agreement found between the computational and experimental results, on both the wear scar areas and volumetric wear rates, suggests that the computational wear modelling based on the new wear law and the experimentally calculated non-dimensional wear coefficient should be more reliable and therefore provide a more robust virtual modelling platform. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1108 / 1116
页数:9
相关论文
共 50 条
  • [1] A new formulation for the prediction of polyethylene wear in artificial hip joints
    Liu, F.
    Galvin, A.
    Jin, Z.
    Fisher, J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H1) : 16 - 24
  • [2] Computational wear prediction of articular cartilage based on a new anisotropic wear law
    Wang, Dangdang
    Zhang, Guoxian
    Jin, Zhongmin
    Li, Junyan
    JOURNAL OF BIOMECHANICS, 2025, 179
  • [3] Wear of polyethylene in artificial knee joints
    Fisher, J
    McEwen, HMJ
    Barnett, PI
    Bell, CJ
    Stewart, TD
    Stone, MH
    Ingham, E
    CURRENT ORTHOPAEDICS, 2001, 15 (06): : 399 - 405
  • [4] Computational wear prediction of UHMWPE in knee replacements
    Zhao, Dong
    Sawyer, W. Gregory
    Fregly, Benjamin J.
    WEAR OF ARTICULATING SURFACES: UNDERSTANDING JOINT SIMULATION, 2006, 1472 : 45 - +
  • [5] Mathematical model and artificial knee joints wear control
    Capitanu, L.
    Vladareanu, L.
    Onisoru, J.
    Iarovici, A.
    Tiganesteanu, C.
    Dima, M.
    JOURNAL OF THE BALKAN TRIBOLOGICAL ASSOCIATION, 2008, 14 (01): : 87 - 101
  • [6] Wear Prediction of Ceramic-on-Ceramic Artificial Hip Joints
    Askari, E.
    Flores, P.
    Dabirrahmani, D.
    Appleyard, R.
    NEW TRENDS IN MECHANISM AND MACHINE SCIENCE: FROM FUNDAMENTALS TO INDUSTRIAL APPLICATIONS, 2015, 24 : 463 - 470
  • [7] Effect of motion inputs on the wear prediction of artificial hip joints
    Liu, Feng
    Fisher, John
    Jin, Zhongmin
    TRIBOLOGY INTERNATIONAL, 2013, 63 : 105 - 114
  • [8] A multiscale computational framework for wear prediction in knee replacement implants
    Li, Yan
    Ma, Chi
    MECHANICS OF MATERIALS, 2022, 175
  • [9] The wear of artificial finger joints using different lubricants in a new finger wear simulator
    Joyce, TJ
    Unsworth, A
    WEAR, 2001, 250 (PART 1) : 199 - 205
  • [10] Wear of polyethylene in artificial hip joints: Superolateral wear of the acetabulum
    Fisher, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02): : 190 - 191