Rem-meter correction factor for high energy neutron outside concrete shielding

被引:0
|
作者
Li, GS [1 ]
机构
[1] Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
关键词
rem-meter; correction factor; high energy neutron; dose equivalent; shielding;
D O I
暂无
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
For the 10 inch diam, single-sphere rem-meter and the standard A-B rem-meter placed outside the concrete shielding wall, correction factors for measuring the high energy neutron dose equivalent produced by intermediate energy heavy ion reaction have been calculated taking into account the energe response of the rem-meter and the effect that the neutron spectra become remarkably "harder" after penetrating through a concrete shielding wall.
引用
收藏
页码:977 / 981
页数:5
相关论文
共 10 条
  • [1] [Anonymous], 1975, ENG COMPENDIUM RAD S
  • [2] BERTINI NW, 1976, PHYS REV C, V14, P590
  • [3] AN EXTENDED RANGE NEUTRON REM COUNTER
    BIRATTARI, C
    FERRARI, A
    NUCCETELLI, C
    PELLICCIONI, M
    SILARI, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (1-2): : 250 - 257
  • [4] NEUTRON PRODUCTION BY HEAVY-ION BOMBARDMENTS
    HUBBARD, EL
    MAIN, RM
    PYLE, RV
    [J]. PHYSICAL REVIEW, 1960, 118 (02): : 507 - 514
  • [5] ICRU, 1993, 51 ICRU
  • [6] Li GS, 1998, HIGH ENERG PHYS NUC, V22, P283
  • [7] Li GS, 1997, NUCL INSTRUM METH A, V394, P381, DOI 10.1016/S0168-9002(97)00415-4
  • [8] LI GS, 1993, ATOMIC ENERGY SCI TE, V27, P167
  • [9] PATTERSON HW, 1973, ACCELERATOR HLTH PHY, P266
  • [10] PRICE BT, RAD SHIELDING