Comparison of Four Intraocular Power Calculation Formulas in Keratoconus Eyes

被引:2
|
作者
Camps, Vicente J. [1 ]
Riad, Ramy R. Fikry [2 ]
Caravaca-Arens, Esteban [1 ]
Labib, Fady E. [3 ]
Mateo, Veronica [1 ]
Caballero, Maria T. [1 ]
Pinero, David P. [1 ,4 ]
机构
[1] Univ Alicante, Dept Opt Pharmacol & Anat, Opt & Visual Percept Res Grp GOPV, Alicante, Spain
[2] Cairo Univ, Dept Ophthalmol, Cairo, Egypt
[3] Al Watany Eye Hosp, Cairo, Egypt
[4] Vithas Medimar Int Hosp, Dept Ophthalmol, Alicante, Spain
来源
关键词
Cataract surgery; Haigis formula; Hoffer Q formula; Holladay; 1; formula; Intraocular lens power calculation; Keratoconus; SRK-T formula; CATARACT-SURGERY; CORNEAL POWER; LENS; ACCURACY; ERROR;
D O I
10.2174/1874364102115010096
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: This study aimed to evaluate the differences in Intraocular Lens (IOL) power in keratoconus (KC) eyes between calculations obtained clinically with the most commonly used formulas in healthy eyes (SRK T, Holladay 1, Hoffer Q and Haigis) as well as to define predictive factors for such differences. Methods: This retrospective study comprised 43 keratoconus eyes of 22 patients with no previous ocular surgery. IOL powers were calculated with SRK T, Holladay 1, Hoffer Q, and Haigis formulas, considering the Effective Lens Position (ELP) of each formula and the desired refraction of 0 D (Rdes=0 D). Results: All differences between formulas were statistically significant and clinically relevant. Haigis formula always provided higher values compared to the rest of the formulas, with the highest differences observed when comparing Haigis with Hoffer (0.84 D) and Hoffer Q (1.17 D) formulas. The lowest difference was obtained for the comparison between SRK-T and Holladay 1 formulas (0.22 D). Differences of the Haigis formula compared to the rest were higher as the magnitude of the IOL power calculated decreased, becoming the patient more myopic. Increased differences between Haigis and Hoffer formulas were observed in eyes with deep anterior chambers, steeper anterior and posterior corneal surfaces, and high axial lengths. Conclusion: The most comparable results in IOL power in keratoconus are provided by the Holladay 1 and SRK T formulas, whereas the Haigis formula provides the most discrepant outcome. The consideration of the curvature of the second corneal surface in IOL power calculations in keratoconus may decrease the variability between calculation methods. However, other factors as anterior chamber depth or axial length are also relevant.
引用
收藏
页码:96 / 102
页数:7
相关论文
共 50 条
  • [1] The comparison of the intraocular lens power calculation formulas in long eyes
    Yildiz, Aydin
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2020, 70 (07) : 1173 - 1176
  • [2] Intraocular lens power calculation in eyes with keratoconus
    Garzon, Nuria
    Arriola-Villalobos, Pedro
    Felipe, Gema
    Poyales, Francisco
    Garcia-Montero, Maria
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (05): : 778 - 783
  • [3] Intraocular lens power calculation in eyes with keratoconus
    Savini, Giacomo
    Abbate, Rosa
    Hoffer, Kenneth J.
    Mularoni, Alessandro
    Imburgia, Aurelio
    Avoni, Luca
    D'Eliseo, Domenico
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (05): : 576 - 581
  • [4] Accuracy of intraocular lens power calculation in eyes with keratoconus
    Kojima, Takashi
    Horai, Rie
    Isogai, Naoki
    Nakamura, Tomoaki
    Tamaoki, Akeno
    Ichikawa, Kazuo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [5] Comparison of intraocular lens power calculation formulas in Chinese eyes with axial myopia
    Liu, Jiewei
    Wang, Li
    Chai, Feiyan
    Han, Yu
    Qian, Suqin
    Koch, Douglas D.
    Weikert, Mitchell P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (06): : 725 - 731
  • [6] Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus
    Wang, Kendrick M.
    Jun, Albert S.
    Ladas, John G.
    Siddiqui, Aazim A.
    Woreta, Fasika
    Srikumaran, Divya
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 212 : 26 - 33
  • [7] Comparison of Different Intraocular Lens Power Calculation Formulas in Eyes With Primary Angle Closure
    Liu, Jinkun
    Wang, Yuhong
    Huang, Weiyi
    Wang, Fei
    Xu, Yazhang
    Xue, Yingying
    Zhao, Zhimin
    Huang, Luping
    Gao, Ruxin
    JOURNAL OF GLAUCOMA, 2024, 33 (09) : 665 - 670
  • [8] Comment on: Accuracy of Intraocular Lens Formulas in Eyes With Keratoconus
    Gonzalez-Lubcke, Eduardo
    Kahuam-Lopez, Nicolas
    Navas, Alejandro
    Ramirez-Miranda, Arturo
    Graue-Hernandez, Enrique O.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 218 : 354 - 355
  • [9] Cataract in keratoconus: Six-month results and a comparison of standard intraocular lens power calculation formulas
    Said, Reeda B.
    Farah, Chahid
    Chanbour, Wassef
    Jarade, Elias
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2022, 36 (02) : 201 - 206
  • [10] Comparison of the accuracy of intraocular lens power calculation formulas for eyes after corneal refractive surgery
    Wang, Xiao-Zhen
    Cui, Rui
    Song, Xu-Dong
    Yun, Bo
    Qian, Jin
    Ding, Ning
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (14)